Loading...
HomeMy WebLinkAbout109 West Yarmouth Road - Septic DesignBENCHMARK TOP OF FOUNDATION ELEV. m 1019 O -•� (ASSUMED) 4' C ST IRON PIPE (OR QUAL) MINIMUM PIT 1/4 PER FT. •ELE1I. gU.G ELEV. a / �'• 20 FT. MINIMUM FROM 10 FT. MINIMUM FROM SLAB 0 CONCRETE COVERS -2 4' SCHEDULE 40 PVC PIPE MIN. PITCH 1/8' PER FT. V. n 7 1 LEVEL r F f7 @AFTLGAS ELEV a o J D 6' SU ELEV. DISTRIBUTION ELEV, (TO BE PLACED ON FIRM BASE) B O X y 6, s J TO BE WATER TESTED 500 GALLON IF MORE THAN ONE OUTLET SEPTIC TANK (TO BE PLACED ON FIRM BASE) 3/4' TO 1 1/2-J WASHED STONE SEWAGE DISPOSAL SYSTEM PROFILE NOT TO SCALE CLEAN SAf� _ OAM AND -SEED 2' kYER OF 444r 1/E TO 1/2' WA4ED STONE VENT J NOT REQUIRED z 1 CU. FT. OF CONCRETE 97�• a ANCHOR e e -' 10' y HIGH CAP CI EINNTI�WI INFILTRATORS TRENCH FORIATION "g WELL WE SOIL ABSORPTION' kA WELE SYSTEM (SAS) INDEX ADJUST USGS PROBABLE WATER TAILE ELEV. _ OBSERVED WATER TABLE ( / / ) ELEV. e, T— BOTTOM OF TEST HILE ELEV. a rr7 3 SOIL TEST DATE OF SOIL TEST Ao(A"f tl, i99 SOIL TEST DONE BY mm WITNESSED BY w'Fs OBSERVATION HOLE 1 ELEV.- 92 ' OBSERVATION HOLE 2 ELEV- PFRM ATION RATE z1, , MIN.ANCH AT -37- INCHES PERCOLATION RATE MIN./INCH AT INCHES DEPTH HORIZ TEXTURE COLOR MOTT. I OTHER A ( oRM Y D I I�nGrl D -q SWEETSER ENGINEERING 235 GREAT WESTERN ROAD 508— P. 0. BOX 713 398-3922 SOUTH DENNIS, MASS. 02660 SAr'O z, 7_f SCALE JOB NO. REVISED �oor3 LOCATION MAP REVISED SWEET OF / u rJYA7 22 f2o G CvR Go tf i 5.9r�7 /I% WATER ENCOUNTERED AT ) 2,01 ELEV. _ £' 7. i LEGEND: EXISTING SPOT ELEVATION 00„0 EXISTING CONTOUR----00---- FINAL SPOT ELEVATION FINAL CONTOUR SOIL TEST LOCATION UTILITY POLE -0- TOWN WATER —WSW CATCH BASIN (® j GAS LINE CLEAN OUT --- CESSPOOL C.P. 0 DEPTH I HORIZ I TEXTURE COLOR MOTT. OTHER WATER ENCOUNTERED AT ELEV. DESIGN CALCULATIONS NUMBER OF BEDROOMS GARBAGE DISPOSAL UNIT NO TOTAL ESTIMATED FLOW 330 GAL�AY REQUIRED SEPPTIC TANK CAPACITYBim) `' CAL ACTUAL SIZE OF SEPTIC TANK 1500 GAL SOIL CLASSIFICATION I DESIGN PERCOLATION RATE < 5 MIN./IN. EFFLUENT LOADING RATE 0,74 CAL/DAY/S.F. LEACHING AREAti 3 `i SQ. FT. LEACHING CAPACITY (AREA X RATE) ZL GAL/DAY Y7Y•3 yo,7`+ RESERVE LEACHING CAPACITY 35�-Ci GAL/DAY NOTES: 1. All WORKMANSMP AND MATERI 2� 7' f90NFORM TO O.E.P. TITLE 5 AND THE TOWN OF RULES AND REGULATIONS FOR THE SUBSURFACE DISPOSAL OF SEWAGE 2. ALL COVERS TO SANITARY UNITS SHALL BE BROUGHT TO WITHIN 6' OF FINISHED GRADE 3. ALL COMPONENTS OF THE SANITARY SYSTEM SHALL BE CAPABLE. OF W17HSfANDING H-10 LOADING UNLESS THEY ARE UNDER OR,WITHIN 10 FT. OF DRIVES OR PARKING AREAS. H-20 LOADING SHALL BE USED UNDER OR WITHIN 10 FT. OF DRIVES OR PARKING AREAS. 4. ANY MASONARY UNITS USED TO BRING COVERS TO GRADE SHALL BE MORTARED IN PLACE 5. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEEDED OR ZONING REGULATIONS. OWNER / APPLICANT IS TO OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY. 6. U71UTIES SHOWN ARE APPROXIMATE ONLY, EXCAVATION CONTRACTOR IS TO CALL 'DIC -SAFE' AT 1-888-344-7233 AT LEAST 72 HOURS PRIOR TO COMMENCING WORK ON SITE 7. CONTRACTOR IS TO VERIFY GRADES AND ELEVATIONS AS WELL AS SITE CONDITIONS PRIOR TO COMMENCING WORK ON SITE ANY VARIATION IS TO BE BROUGHT TO THE ATTENTION OF THE DESIGN ENGINEER IMMEDIATELY. B. PARCEL IS IN FLOOD ZONE C 9. LOT IS SHOWN ON ASSESSORS MAP �LL AS PARCEL Y /n. E/'4 r/., e., Cn`'SS Inc+4t f5 7c� r4- P✓---< '4 6_'c"rrw✓�c�. APPROVED: BOARD OF HEALTH DATE AGENT �`;C,,sr-. \ rr/Zr4•acu RL v J PROPOSED SEPTIC DESIGN f FOR Out l�,R-i?' �o�'/� ,��✓c• PROJECT LOCATION tc r7 ft ra lelz. /«'9D� W' SWEETSER ENGINEERING 235 GREAT WESTERN ROAD 508— P. 0. BOX 713 398-3922 SOUTH DENNIS, MASS. 02660 DATE�UG US i Z6 I/ y SCALE JOB NO. REVISED LOCATION MAP REVISED SWEET OF /