Loading...
HomeMy WebLinkAbout906 and 910 West Yarmouth Road Site Plan 2LEGEND .99- EXISTING CONTOUR X 99.7 EXIST. SPOT ELEV. -EM- PROPOSED CONTOUR (98.41 PROPOSED SPOT EL TH1 m 150' TEST HOLE VI SLOPE OF GROUND to 0 Zvi UTILITY POLE N L FIRE HYDRANT NOTE NOT ALL SYMBOLS MAY APPEAR IN DRWfM *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM 2. MUNICIPAL WA'VER88 3. MINIMUM PIPE PITCH IRRBEOW PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H -1A 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT UNE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4' PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. DCE #14-081 SYSTEM PROFILE #1 EKED COMPONENTSMAGNETIC APE OR COMPARABLE MEANS FOR FUTURE LOCATION. (NOT TOSCALE) ACCESS COVERS TO WITHIN 6" OF FIN. GRADE2' PEASTONE OR GEOTEXDLE CONCRETE COVERS TO WITHIN 3' GRADE TOP FOUND. EL. 55.5' FILTER FABRIC OVER STONE 54.5 MINIMUM .75' OF COVER OVER PRECAST 2X SLOPE REQUIRED OVER SYSTEM .1 PRIMA= H-10 WATERTEST D'BOX FOR LEVELNESS BLOCKS OR PRECAST RISERS NSOs PrP.) 2y 4'0SCH40 PVC - MORTAR ALL PIPES LEVEL IST 2' 4• COMPONENTS INVERT IN 50.67 4, F8111 �•) SID5 * t0• 1500 GAL H-10 14' ,;'51TEE SEPTIC TANK TEE .12' ®DDDDD�®�GAS BAFFLEnQ4' V0. LEVEL ACME OR EQUAL) ,;50.94'5 .7T JpeDDDDo'ODDOODDDQaeDODoaDDDDDDDDDDODDDaDDODOO` 'yovogogD�e�ooD, DaDeDaDODnDrDpYpD�D.D,D;?yD,DDH-10 500 GAL LEACHING CHAMBERS BY ACME PRECAST OR EOL 3/1/2' DOUBLE WASHED STONE 4' MIN.. (2) UNITS REQUIRED ALL AROUND PRECAST STRUCTURES 4 6' CRUSHED STONE OR MECHANICALOVERALL DIMENSIONS TO OUTSIDE OF STONE: 25.00' x 12.63' L� COMPACTION. (15.221 [2y - (2.5z SLOPE) (-x SLOPE) t z SLOPE) MIN FOUNDATION- 77' - SEPTIC TANK 9' D' BOX 12' LEACHING 43.5' BOTTOM TH-4 FACILITY NO GROUNDWATER FOUND SYSTEM PROFILE #2 ► ASYSTEM LL HOUMAGNETICC TAPE BE (NOT TO SCME) COMPARABLE MEANS FOR FUTURE LOCATION. ACCESS COVERS TO WITHIN 6" OF FIN. GRADE r PEASTONE OR GEOTEXTIL.ECONCRETE COVERS TO WITHIN 3" GRADE FOUND. EL. 55.5' FILTER FABRIC OVER STONE _ 54.5 MINIMUM .75' OF COVER OVER PRECAST 1 F2% SLOPE REQUIRED OVER SYSTEM 53.5 1 PHEGl4T H-10 WATERTEST D'BOX FOR LEVELNESS BLACKS OR N� �) PRECAST RISERS ro 4"OSCH40 PVC MORTAR ALL INVERT IN 49.67' . .PIPES LEVEL 1ST 2' �4• COMPONENTS ENDS �•) 0'* 10. 1500 GAL H-10 14• o 50.45' TEE SEPTIC TANK TEE O. � ��� � ��p3 9 A egpgggg GAS BAFFLE: DDDR° �'"D..D°D°DD.S - - •.D.,D ® BBB B V U0. LEVEL (ACME OR EQUAL) :; 49.94 _ 44 •'�� JDODDDODOOOODOODOpDpOQODODODODODODODODODDDOD4 •o,,DD,DDD DD^,D,pDeDg,g,�,�,g,�,�,DDD,D,FH-10 500 GAL LEACHING CHAMBERS BYIR ACME PRECAST OR EOL D�D�a.o .+. o o.D • 3/4'-1-1/2" DOUBLE WASHED STONE 4' MIN. ALL AROUND PRECAST STRUCTURES (2) UNITS REQUIRED j 6' CRASHED STONE OR MECHANICAL OVERALL DIMENSIONS TO OUTSIDE OF STONE: 25.00' X 12.83' COMPACTION. (15221 12D IM z SLOPE) ( x SLOPE) (-!-X SLOPE) FOUNDATION- 22' - SEPTIC TANK 13' D' 80X 12' LEACHING 42.5' BOTTOM TH-2 FACILITY - NO GROUNDWATER FOUND A PPROX HYD io�6 m 54.5 3 N n BENCHMA _ 2 .24' CONCRETE B N N 4'08'38" EL = 47.34' W LOT 1 ------ ----- ----- ------ co I 32,918 Sq Ft ------- -- 0.76 Ac. 54 1 S.N. 19.22 j MAP 115 PCL 216.3.2 o I R� o I o wOA n O I hry co U T. 1 133.6' w' w w � " " w - I I I SO I I L---- E _ A - E � B TO E--�E� a� BE T 'E Ems- S2 e\ 77.15' fire\F 22.12' i Ewe � J. rm ID OO v 0 A r Z SYSTEM LOT #1 DESIGN: GARBAGE DISPOSER IS NOT ALLOWED PROPOSED 3 BEDROOM DWELLING DESIGN FLOW: 3 BEDROOMS 0 110 GPD = 330 GPD USE A 330 GPD DESIGN FLOW SEPTIC TANK: 330 GPD (2) = 660 USE A 1500 GAL SEPTIC TANK LEACHING: SIDES: 2 (25 + 12.83) 2 (.74) = 112 GPD BOTTOM 25 x 12.83 (.74) = 237 GPD TOTAL- 472 S.F. 349 GPD USE (2) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH 4' STONE ALL AROUND SYSTEM LOT #2 DESIGN: GARBAGE DISPOSER IS NOT ALLOWED PROPOSED 2 BEDROOM DWELLING DESIGN FLOW: 2 BEDROOMS @ 110 GPD = 220 GPD USE A 220 GPD DESIGN FLOW SEPTIC TANK: 220 GPD (2) = 330 USE A 1500 GAL. SEPTIC TANK LEACHING:. SIDES: 2 (25 + 12.83) 2 (.74) = 112 GPD BOTTOM 25 x 12.83 (.74) = 237 GPD TOTAL- 472 S.F. 349 GPD USE (2) 500 GAL LEACHING CHAMBERS (ACME OR EQUAL) WITH 4' STONE ALL AROUND NOTE: 2 BEDROOM DEED RESTRICTION SHED JI 1 0 000 O J Z Q 'E E 0 T 4 ----- -- _ V w UA ----- _ --_- N ZONING SUMMARY LOT 1 w ZONING DISTRICT: R-40 RESIDENTIAL DISTRICT < 2 MIN/INCH 1i EXISTING PROPOSED MIN. LOT SIZE 40,000 S.F. 32,918 S.F. m 150' LU � 30' to 0 Zvi MIN. SIDE SETBACK N L t^ Cy LU !� to MAX. BUILDING COVERAGE n 0 000 O J Z Q 'E E 0 T 4 ----- -- _ V w UA ----- _ --_- N ZONING SUMMARY LOT 1 SE #13587 ZONING DISTRICT: R-40 RESIDENTIAL DISTRICT < 2 MIN/INCH PERC EXISTING PROPOSED MIN. LOT SIZE 40,000 S.F. 32,918 S.F. MIN. LOT FRONTAGE 150' 120.6' MIN. FRONT SETBACK 30' 133.6' MIN. SIDE SETBACK 20' 32.8' MIN. REAR SETBACK 20' 98.4' MAX. BUILDING COVERAGE 25% 5.54% IMPERVIOUS COVERAGE 120.5' 10.37% VARIANCES REQUESTED: UNDER TOWN OF YARMOUTH HEALTH REGULATIONS: (3.7): REDUCTION IN FOUNDATION HEIGHT ABOVE HIGH POINT IN ROAD (2' TO 1') ZONING SUMMARY LOT 2 SE #13587 ZONING DISTRICT: R-40 RESIDENTIAL DISTRICT < 2 MIN/INCH PERC EXISTING PROPOSED MIN. LOT SIZE 40,000 S.F. 20,144 S.F. MIN. LOT FRONTAGE 150' 74.0' MIN. FRONT SETBACK 30' 104.6' MIN. SIDE SETBACK 20' 26.0' MIN. REAR SETBACK 20' 120.5' MAX. BUILDING COVERAGE 25% 5.58% VARIANCES REQUESTED: UNDER TOWN OF YARMOUTH HEALTH REGULATIONS: (3.7r REDUCTION IN FOUNDATION HEIGHT ABOVE HIGH POINT IN ROAD (2' TO -2.3') C n p J 1 \\ I I 2 .40' \ I S 85.08'53" E 1 154.12' I CBT I BE SE TF1 1 1 20.01' I e - ----- 2 I 1 -" w w- 1 �i q ------------ I W w w rn V) 56 2 " -w-9_ w PROPOSED Oa -- - - ��`_ o I 1 DWELLING � - - - _ _ _ I � r I G,% .�G i� 2 BEDROOM D� TOF.= 55.5 O 52 lw 12_ #906 00�� C� Io W Lu Lf) - - 104.III 6' '7' Nt N O a o ------------------ SHED OT 2 o oQi 20' NON-EXCL SI b�� ---_ _ �44 SCS Ft DRIVEWAY EASEMENT ro S 9'14'26" E (`III S8 V a BENCHMAR CONCRETE BOUN EL - 58.43 v 0.46ECC.-----(�20'W ° 3 S.N. 23.7 1 0 4' MAP 115 PCL 216.3.1 $ " I o 52.14' 1 N 20.00' S 84'1 52 TEST HOLE LOGS ENGINEER: DANIEL E. GONSALVES, WITNESS: PHIL RENAUD DATE: 6/4/14 SE #13587 PERC. RATE _ < 2 MIN/INCH PERC LS CLASS I SOILS 1OYR 3/2 1OYR 3/2 ( ELEV. 6" B ( ELEV. Q 0" 53.0' 0" 53.5' A 1OYR 5/6 45" 1OYR 5/6 50.8' A LS TITLE 5 LS 1OYR 3/2 1OYR 3/2 6" 8" B B LS LS 34' 1 OYR 5/6 50.2' 35" 1 OYR 5/6 50.6' LOCUS MAP NOT TO SCALE ASSESSORS MAP 115 PARCEL 216.3.1, 216.3.2 OWNER OF RECORD OUR FIRST HOME, INC. 86 WILLOW STREET YARMOUTHPORT, MA 02675 REFERENCES CERT 206567 LCP 43317A, PET. PLAN REVISED APRIL 2, 1999 BY THE TOWN OF YARMOUTH ENGINEERING DEPARTMENT. COMPREHENSIVE PERMIT RECORDED DOC#1,263,530 REFERENCE PLAN OF LAND DATED APRIL 20, 2015 REV. JUNE 22, 2015 AND ENDORSED BY THE ZBA NOTE: DATUM : NAVD88 ZONING RELIEF NEEDED FOR INDICATED LOT CONFIGURATION. (AREA, FRONTAGE, SHAPE NUMBER) WETLAND (IVW) ASSUMED >100' FROM LOCUS PER DEP MAPPING Q Q s ELEV. w ELEV. 54.5' O" v 54.5' - A - C A PERC LS LS 1OYR 3/2 1OYR 3/2 4" MS 6" B B 2.5Y 7/6 LS LS F51.2, 40" 1OYR 5/6 45" 1OYR 5/6 50.8' C C C C PERC PERC M/CS M/CS MS MS 1OYR 6/8 1OYR 6/8 2.5Y 7/6 2.5Y 7/6 120"43_0' 132" 4- 120" 44_5' 132" 1 43_5' NO GROUNDWATER ENCOUNTERED NO GROUNDWATER ENCOUNTERED TITLE 5 ITEF'O'LAN OF #906 & #910 WEST YARMOUTH ROA1, l.i PREPARED FOR OURFIRST HOME IN rmouthmalthDezrtme. DATE: DECEMBER 5, 2014 F---� i REV. JULY 15, 2015 lame Date _ REV. AUGUST 19, 2015 mss°, //oyQyGi- �- SrICFIIRS cp`SNOF�eAss Scale:l = 20 � DOJALA DANIEL A. 0 10 20 30 40 50 FEET " CNIL '" OJALA N \p NO. 455020 No. 40980 ?FF ^STE SE EN iyaFEss ° off 508-362-4541 o� I fax 508-362-9880 N+q®R�Ey downcape.com doWO cope engineoIIIIIIInc. civil engineers land surveyors DATE DANIEL A. OJALA, P.E., P.L.S. 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675