Loading...
HomeMy WebLinkAbout906 and 910 West Yarmouth Road Site Plan 5LEGEND _99- EXISTING CONTOUR X 991 EXIST. SPOT ELEV. PROPOSED PROPOSED CONTOUR �98•4j PROPOSED SPOT EL. TH1 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO p TEST HOLE 2z; SLOPE OF GROUND rQ1 UTILITY POLE 133.6' FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM 2. MUNICIPAL WAVM81S 3. MINIMUM PIPE PITCH ' MSEOSEffi' PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS RESIDENTIAL DISTRICT TO BE AASHO H-111 5. PIPE JOINTS TO BE MADE WATERTIGHT. PROPOSED 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH LOT SIZE 310 CMR 15.000 (TITLE 5.) 32,918 S.F. 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO p BE USED FOR LOT LINE STAKING OR ANY OTHER W PURPOSE. FRONT SETBACK B. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4' PVC. 133.6' 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED SIDE SETBACK WITHOUT INSPECTION BY BOARD OF HEALTH AND 32.8' PERMISSION OBTAINED FROM BOARD OF HEALTH. REAR SETBACK 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING �r DIGSAFE (1-888-344-7233) AND VERIFYING THE W LOCATION OF ALL UNDERGROUND do OVERHEAD UTILITIES IMPERVIOUS COVERAGE PRIOR TO COMMENCEMENT OF WORK. 10.37% 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. SYSTEM PROFILE #1 �, Sl �°"TA SHALL BE COMPARABLE MEANS FOR FUTURE LOCATION. (NOT To Sl ACCESS COVERS TO WITHIN B' OF FIN. GRADE2' PEASTONE OR GE0ITJOREF2Z CONCRETE COVERS TO WITHIN 3' GRADE 55.5' FILTER FABRIC OVER STONE 54.5' MINIMUM .75' OF COVER OVER PRECAST SLOPE REQUIRED OVER SYSTEMBLOCKS OR 54.5 1 ��•{j PRLv6T N-10 WATERTEST D'BOX FOR LEVELNESS - PRECAST RISERS I"I SEM M) 4'0SCH40 PVC MORTAR ALL Will IN 50.67' PIPES LEVEL 1ST 2' ,4 COMPONENTS t9tos (TVP.) So 5 51.80'4 t0. 1500 GAL HJE E'2's -® e 51 37' TEE SEPTIC rAN1.12'®®�E� - ° °_' .s.^o.4' LIQ. LEVEL ACME 50.94 :�.. ' '} � •oo oe$e000�oga0000vae 000$�$o,"poag>,osevoovoaeo '"0 500 GAL LEACHING CHAMBERS BY ACME PRECAST OR EQt e„•. _ _ 3/4--t-1/2-DOUBLE WASHED STONE a MIN. ALL AROUND PRECAST STRUCTURES (2) UNITS REQUIRED 6' CRUSHED STONE OR MECHANICAL OVERALL DIMENSIONS TO OUTSIDE OF STONE 25.00' X 12.83' COMPACTION. (15.221 [2]} (2.5 z SLOPE) ( ? x SLOPE) Cj-z SLOPE) MIN LEACHING FOUNDATION- 17' -SEPTIC TANK 9' D' BOX 435' BOTTOM TH-1 12' FACILITY No GROUNDWATER FOUND SYSTEM PROFILE #2 IC°L TAPE OR (tw TO SCu4 COMPARABLE MEANS FOR .FUTURE LOCATION. ACCESS COVERS TO WITHIN B' OF FIN. GRADE r PEASTONE OR GEO[EXTILECONCRETE COVERS TO WITHIN 3' GRADE TOP FOUND. EL 55.5' FILTER FABRIC OVER STONE 54.5' MINIMUM .75' OF COVER OVER PRECAST 2% SLOPE REQUIRED OVER SYSTEMULM53.5 WATERTEST D'BOX FOR LEVELNESS xS OR •' Pli£Gl4'T N -m PRECAST RISERS AR ALL - p '1 671 - M - F�iPIPES LE PVC ��1111C� MOftPONENT•) INVERT IN 4� PIPES LEVEL 15f 2' 4, COOMPONENTS 4. 51 .0'* u 10• 1500 GAL H-10 14• 50.45' TEE SEPTIC TAN K0.4 J51K TEE @® go ogog GAS BAFFLE:coo 0 ° e"0° -Is 0%°go°go 4 4' LIQ. LEVEL ACME ORE 49.94' �.: ?•s!.a apeooeu0000eoe000°ooe0000000e.0000000°o°n°ue. oe a a' ° a„e a eeoe°°°,e„°�°•°•°•°•.•°e•eee ' ° °LH -i/2' -10.500 GAL LEACHING CHAMBERS BY ACME PRECAST OR EQI 31,1 OOUBLE WASHED STONE 4' MIN. (2) UNITS REQUIRED ALL AROUND PRECAST STRUCTURES S' CRUSHED STONE OR MECHANICAL OVERALL DIMENSIONS TO OUTSIDE OF STONE: 25.00' X 12.83' L.� COMPACTION. (15.221 [2U - N 1L SLDPE) C R SLOPE) ( PE} x SHA 13' D' BOX 12' TEACHING 42.5' BOTTOM TH-2 FOUNDATION- 22 -SEPTIC TANK FACILITY NO GROUNDWATER FOUND PA PROX HYD N L0 SYSTEM LOT #1 DESIGN: GARBAGE DISPOSER IS NOT ALLOWED PROPOSED 3 BEDROOM DWELLING DESIGN FLOW: 3 BEDROOMS 0 110 GPD = 330 GPD USE A 330 GPD DESIGN FLOW SEPTIC TANK: 330 GPD (2) = 660 USE A 1500 GAL. SEPTIC TANK LEACHING: SIDES: 2 (25 + 12.83) 2 (.74) = 112 GPD BOTTOM 25 x 12.83 (.74) = 237 GPD TOTAL: 472 S.F. 349 GPD USE (2) 500 GAL LEACHING CHAMBERS (ACME OR EQUAL) WITH 4' STONE ALL AROUND SYSTEM LOT #2 DESIGN: GARBAGE DISPOSER IS NOT ALLOWED PROPOSED 2 BEDROOM DWELLING DESIGN FLOW: 2 BEDROOMS ® 110 GPD = 220 GPD USE A 220 GPD DESIGN FLOW SEPTIC TANK: 220 GPD (2) = 330 USE A 1500 GAL. SEPTIC TANK LEACHING: SIDES: 2 (25 + 12.83) 2 (.74) = 112 GPD BOTTOM 25 x 12.83 (.74) 237 GPD TOTAL: 472 S.F. 349 GPD USE (2) 500 GAL LEACHING CHAMBERS (ACME OR EQUAL) WITH 4' STONE ALL AROUND NOTE: 2 BEDROOM DEED RESTRICTION ZONING SUMMARY LOT 1 ZONING DISTRICT. R-40 RESIDENTIAL DISTRICT NOTE: EXISTING PROPOSED BENCHMA EL 4 NO LOT SIZE 2 .-38 N 4'08'38" 32,918 S.F. MIN. 150' 120.6' MIN. FRONT SETBACK 30' 133.6' MIN. SIDE SETBACK 20' 32.8' MIN. REAR SETBACK 20' 98.4' MAX. W 5.54% IMPERVIOUS COVERAGE WITNESS: PHIL 10.37% MAPPING DATE: 6/4/14 LOT 1 -------- -- --------____ ------ < 2 MIN/INCH � 20. � • CLASS I SOILS Sq Ft0.76 (� I III 4 �{ ELEV. Q Q ELEV. 0^ 53.0' O' 53.5' 0' 54.5' 0' 54.5' Ac. /y4S.N. LS [1.OYR LS LS \1321918 19.22 LS SHED 3/2 20.0' 10YR 3/2 10YR 3/2 10YR 3/2 AP 115 PCL 216.3.2a 6" 8" 4" 6" _B �� B Q B B LS LS LS O CD..0 tc 10YR 5/6 50.2' 35" 10YR 5/6 50.6 40^ 10YR 5/6 51.2'45n Q A t R 36 _� �! \ @ ® C C En o 00 o C ' 9p�$:� - 4 w- -w -� 33.6' w --W _w to �F ; i0 _o iV Ml MS Iw -w_ w 1OYR 6/8 rm- r \ EQ cv } fN 2.5Y 7/6 000 Z t o So 0 L__-- --- ------------ E _w7 \ -------- ------ --------------- 41 B BE TO T E��E.� Ems- o� -----• - 54.5 'E� S2 -------- a (A `� 77.15' 2� n D 1 1 r ZONING SUMMARY LOT 1 ZONING DISTRICT. R-40 RESIDENTIAL DISTRICT NOTE: EXISTING PROPOSED MIN. LOT SIZE 40,000 S.F. 32,918 S.F. MIN. LOT FRONTAGE 150' 120.6' MIN. FRONT SETBACK 30' 133.6' MIN. SIDE SETBACK 20' 32.8' MIN. REAR SETBACK 20' 98.4' MAX. BUILDING COVERAGE 25% 5.54% IMPERVIOUS COVERAGE WITNESS: PHIL 10.37% VARIANCES REQUESTED: UNDER TOWN OF YARMOUTH HEALTH REGULATIONS: REDUCTION IN 2FOTD D ATION HEIGHT ABOVE HIGH POINT IN ZONING SUMMARY LOT 2 ZONING DISTRICT: R-40 RESIDENTIAL DISTRICT NOTE: EXISTING PROPOSED MIN. LOT SIZE 40,000 S.F. 20,144 S.F. MIN. LOT FRONTAGE 150' 74.0' MIN. FRONT SETBACK 30' 104.6' MIN. SIDE SETBACK 20' 26.0' MIN. REAR SETBACK 20' 120.5' MAX. BUILDING COVERAGE 25% 5.58% IMPERVIOUS COVERAGE WITNESS: PHIL 15.39% VARIANCES REQUESTED: UNDER TOWN OF YARMOUTH HEALTH REGULATIONS: (3.7)-. REDUCTION IN FOUNDATION HEIGHT ABOVE HIGH POINT IN ROAD (2' TO -2.3') -x---x-x-'x_ ? E\ 22.12' 2 .40' x S E\ i 85'08'53" 1 x N e E / j N E 154.12. 1 CBT x�_x- i�e 1 BE SE 4 ------- - -- /� e / THt 1 20.01' I r- __ r i� t --------- 2 w_wl �� q ----------- I Ld c� 01 i7, 56 p�2v w --w / w PROPOSED DWELLING 0 z) S G,;� X100' 2 BEDROOM -X� ,, i� o TOF = 55.5 0 52 I w r W _ 0 I Hipp n #906 �$Q� / Q --:1 <V O b I N� M �y --LID ----- OT 2 ^io N----------------- - SHED e¢ O 20' NON-EXCLUSI c IZ +57.So N ----- - DRIVEWAY EASEMENT m - - 2 x144 Sq Ft i ¢ C) 40.31' 0.4� I�C.-----j�20'Z ° 0 o S 9'14'26" E S.N. 23.7 1 p S8 84'S'6' MAP 115 PCL 216.3.1 i 1E" 1 0 41 52.14' 1 a BENCHMAR S 84'41'30" 20.00' CONCRETE OUND EL - 58.43 �v � 52� � ^ DCE ## 14-081 LOCUS MAP NOT TO SCALE ASSESSORS MAP 115 PARCEL 216.3.1, 216.3.2 OWNER OF RECORD OUR FIRST HOME, INC. 86 WILLOW STREET YARMOUTHPORT, MA 02675 REFERENCES CERT 206567 LCP 43317A. PET. PLAN REVISED APRIL 2, 1999 BY THE TOWN OF YARMOUTH ENGINEERING DEPARTMENT. COMPREHENSIVE PERMIT RECORDED DOC#1,263,530 REFERENCE PLAN OF LAND DATED APRIL 20. 2015 REV. JUNE 22, 2015 AND ENDORSED BY THE ZBA TEST HOLE LOGS NOTE: DATUM : NAVD88 ZONING RELIEF NEEDED FOR INDICATED LOT ENGINEER: DANIEL E. GONSALVES, SE #13587 CONFIGURATION. (AREA, FRONTAGE, SHAPE NUMBER) WETLAND (IVW) ASSUMED >100' FROM LOCUS PER DEP WITNESS: PHIL RENAUD MAPPING DATE: 6/4/14 PERC. RATE _ < 2 MIN/INCH • CLASS I SOILS ELEV. (� I III 4 �{ ELEV. Q Q ELEV. 0^ 53.0' O' 53.5' 0' 54.5' 0' 54.5' LS [1.OYR LS LS LS 3/2 10YR 3/2 10YR 3/2 10YR 3/2 6" 8" 4" 6" _B B B B LS LS LS LS 34" 10YR 5/6 50.2' 35" 10YR 5/6 50.6 40^ 10YR 5/6 51.2'45n 10YR 5/6 50.81 C C C C PERC PERC M/CS Ml MS MS 1OYR 6/8 1OYR 6/8 2.5Y 7/6 2.5Y 7/6 120" I 43_0' 132" L 42.5' 120" 1 44_5' 132" 1 43_5' NO GROUNDWATER ENCOUNTERED NO GROUNDWATER ENCOUNTERED TITLEIT OF l111 •11,0)101- - A: PREPARED FOR OUR FIRST !-TOME INC r Yarmouu, k1t.11th Department DATE: DECEMBER 5, 2014� PPR VED REV. JULY 15, 2015 ( F-1' REV. AUGUST 19, 2015 acre Date Scale: 1"=72 DAI CIVIL4C,5--2 3 O,A. .I 0 10 20 30 40 50 FEET u' a �Nc.40980 off 5D8-362-4541 fox 508-362-9880 L ��sur,14 downccpe.corn d0WO C4150 10' Iferinig, Inc. civil engineers g land surveyors DATE DANIEL A. OJALA. P.E.. P.L.S. 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675