HomeMy WebLinkAbout526 West Yarmouth Road - Proposed Septic DesignDEPTH HpRiZ 7.00 COLOR MOTT. OTHER 0-7 0/A LOAMY SAND 10Y R4/4, NO ROOTS 7-29 8883 MAX VENT 1OM/6 ROOTS 29-120 C MEQ./COAR. 4" CAST IRON PIPE SOIL TEST COARSE SAND SAND " A SHEFFIE D TOP OF FOUNDATION 0 ELEV. = 104.00 10 FT. MINIMUM 20 FT. MINIMUM FROM CELLAR 10 FT. MINIMUM FROM SLAB OR CRAWL SPACE MOCKINGBIRD \ CLEAN SAND Wvs o�u� DATE OF SOIL TEST OCTOBER_2& 1999_ SOIL TEST DONE BY tWEETSER.ENGINEERING WITNESSED BY K.WELSH CONCRETE COVERS09SERVA110N $ SCHEDULE 40 PVC PIPE MIN. PITCH 1/8" PER' FT, SHEET -1 _ OF 1 . INSPECTION PORT' LOAM AND SEED 2" LAYER OF 1/8" TO 1/2' PERCOLATION RATE HOLE 1 ELEV. <_ 2_ MIN./INCH 97.2 AT - 68 INCHES 08SMVA110N PERCOLATION RATE HOLE 2 ELEV.= 97.1 _«__ MIN./INCH IN C HORIZON PITCH 1/4" PER FT.rl WASHED STONE Z DEPTH HpRiZ 7.00 COLOR MOTT. OTHER 0-7 0/A LOAMY SAND 10Y R4/4, NO ROOTS 7-29 8883 MAX VENT 1OM/6 ROOTS 29-120 C MEQ./COAR. 4" CAST IRON PIPE .0 COARSE SAND SAND " A SHEFFIE D 95.38 MIN. IRED MOCKINGBIRD \ ,LOB No, 4635;037, Wvs o�u� (OREQUAL)MINIMUM REV' PCT., 18,` X013 - SHEET -1 _ OF 1 . -• LOCATION MAP PITCH 1/4" PER FT.rl Z FLOW LINE 85.83. _ ELEV. _ 97.00 - 10" MIN. O e ELEV. _ _98_00 1� u 94.30 ELEV. _ _QBS GAS ELEV. _ _95_30 6'pSUMP �tyL= AIR - a `_ ' ELEV. _ BAFFLE DISTRIBUTION WELL N A LIQUID OUTLET V BOX ELEV. + 4 HIGH CAPACITY INFILTRATORS WITH ONE INDEX DEPTH TFr (T0 BE PLACED ON FIRM BASE) TO BE WATER TESTED -85A3'` STONE IN AN Z ADJUST DEPTH HpRiZ TEXTURE COLOR MOTT. OTHER 0-7 0/A LOAMY SAND 10Y R4/4, NO ROOTS 7-29 B LOAMY SAND 1OM/6 ROOTS 29-120 C MEQ./COAR. 10YR8/6 .0 COARSE SAND SAND v^TESEPT.' , 20, , 2013 DEPTH HORIZ TEXTURE COLOR , MOTT. .OTHER 0-10' O/A LOAMY SAND 1OYR5/6 NO ROOTS 10-28 - B LOAMY SAND IOYR6/8 ROOTS 28-120 .0 COARSE SAND 2.5Y6/3 v^TESEPT.' , 20, , 2013 4 FEET 14 INCHES - 11' X 38' X.10'' -TRENCH FORMATION 1 5 FEET 19 INCHES SIF 1d9RE THAN ONE OUTLET 6 FEE 24 INCHES 1500 GALLON G� p � 20 NO WATER ENCOUNTERED AT _ 120. ELEV. _ _,$Z2 NO WATER ENCOUNTERED AT _SIR_ ELEV. 87.1 7 FEE{ 29 INCHES T (TO BE PA -ACED -ON- F tlf`M BASE) SOIL ABSORPTION 8 FEET 34 INCHES SEPTIC TANK &L96.13/4" TO 1 1/2 �CLQ 9(gAS) I DOUBLE WASHED STONE SYSTEM �jAS) FREE of FINESd "§!II.T . 9 .B DESIGN CALCULATIONS USGS PROBABLE WATER TABLE ELEV. _ NUMBER OF BEDROOMS I ` SEWAGE DISPOSAL. :SYSTEM ''PROFILE OBSERVED WATER TABLE ( / J )ELEV. • __� GARBAGE DISPOSAL UNIT , \ NOT TO SCALE BOTTOM OF TEST HOLE ELEV. TOTAL ESTIMATED FLOW ( 110 GAL./BR./DAY X _ 3 .34_ GAL/DAY I REQUIRED SEPTIC TANK CAPACITY _650_ GAL. !{ O f S. ,130 ACTUAL SIZE OF SEPTIC TANK 1500 GAL. SOIL CLASSIFICATION _ I \K DESIGN PERCOLATION RATE MIN./IN, • 98,7 EFFLUENT LOADING RATE ._.9,74GAL/DAY/S.F.' �'- LEACHING AREA A7!33 SO. FT. l / % ' (11X36)+(47X2X10/12) 98.8 100.8 I \ 96.6. / LEACHING CAPACITY (AREA X RATE) GAG/DAY E LEACHING .74 31 G CAPACITY 37 '� "DRIVE �-- �- RESERV � ��i,QQ GAL/DAY 104) , \ NOTES:WORKMANSHIP AND MATERIALS SHALL'CONFORM TO D.E.P. TITLE 5,AND THE TOWN'S RULES AND'REGULATIONS WOR THE SUBSURFACE DISPOSAL OF SEWAGE. �' o _�� /m (• 102.3 I�'} 85.00' ALL I \ 2 TO SANITARY GRADE. BE OUGHT (0 SHALL BE .BR IS tOt.7 R 96.8 \ -' \ \ \ I 3. ALL COMPONENTS OF THE SANITARY SYSTEM SHCAPABLE OF WIT0 FT. OF ING DRIVESIORLP RING KNG AREAS. HE20 LOADUNDER NG SHALL BEIM' l m \ \ USFD UNDER OR WTHN10 FT. OF DRIVES OR PARKING -AREAS. 4. ANY MASONRY UNITS USED ,TO BRING COVERS TO GRADE SHALL 'SOIL BE.MORTARED IN. PLACE:..i i TEST 1, paJ 5. NO DETERMINATION HAS BEEN MADE,AS TO �COMPUANCE,NATH -DEEDED .OR ZONING REGULATONS. OWNER /- APPLICANT 15 TO . 100.9 i s I SOLI TEST 2 e \\ \ \ I I \ !^ OBTAIN SUCH DETERMINATION FROM APPROPRIATE 'AUTHORITY, O / ` \ , T 97:8- ' J e \ \ / \ �� ��' rQ%% NE 6. S TOICALL H -DIG-SAFE" AT 1-888-344-7233 888--344 7233 ATALEAST 072 HOURS I 97.5 I \ I GBI �Y 7.-CONTRACTORPRIOR TO MISENCING TO VERIFFYRK ON.SITE. GRADES AND ELEVATIONS' AS WELL A5 0fv +`' SITE CONDITIONS PRIOR TO COMMENCING WORK ON SITE.,ANY VARIATION DRIVE IS TO BE BROUGHT TO -THE ATTENTION Or,THE DESIGN ENGINEER IMMEDIATELY. f 1500. G�LLON ` ! �-- 8. PARCEL IS.IN FLOOD ZONE, 0 1 I , SEPTI C TANK \�! '"\1 4. _ IS SHOWN ON ASSESSORS MAP 7A AS PARCEL _ 200 10.0 9 LOT D. m j 100 10. PARCEL HAS THE BENEFIT OF AN APPROVED NITROGEN AGGREGATION 7 \. I 9 .5 I APPROVAL RECORDED iN BK.'20785 PGS. 127 134 ALLOWING THE o BOX ` CONSTRUCTION OF A 3 BEDROOM DVIELLING: I „ ,p oJ� .40.0' !%`I c1<, �T,• 97'1 ,n �,a�• 'FyQ �, - 100.7it . j I I�I •O1kO.0 .97.2 F HEALTH UAxiW. BOARD fffRV a Y l p Tam DATE AGENT 44.0f a 1 •105 '- • 96.7 Yarmouth Health Department GEND: • 96'.9 OVER XISTING SPOT, ELEVATION - %0.0 STING CONTOUR CONTOUR ----00---- NAL SPOT ELEVATION 04 Name Date INAL CONTOUR ELEVATION to f OIL'TEST LOCATION ® ` ZLIGQ �.- lot UTILITY POLE CULJ LOT 1 / I I y 11 .2 OWN WATER -WSW /1 ^ r 29,1966 i' S.F. , I E CH BASIN LINE G / SPOOL CP OLEANOUT PROPOSED SEPTIC DESIGN FOR, DUBLIN CONSTRUCTION OLD TOWNHOUSE / .LOC. LOT 3, . # � 6 i,. YARIAOUTH ROAD, TWT YAWOUTH CONSSANCE j 11 0 } i a w U v^TESEPT.' , 20, , 2013 SHEFFIE D SCALE. 20' MOCKINGBIRD \ ,LOB No, 4635;037, Wvs o�u� REV' PCT., 18,` X013 - SHEET -1 _ OF 1 . LOCATION MAP 44.0f a 1 •105 '- • 96.7 Yarmouth Health Department GEND: • 96'.9 OVER XISTING SPOT, ELEVATION - %0.0 STING CONTOUR CONTOUR ----00---- NAL SPOT ELEVATION 04 Name Date INAL CONTOUR ELEVATION to f OIL'TEST LOCATION ® ` ZLIGQ �.- lot UTILITY POLE CULJ LOT 1 / I I y 11 .2 OWN WATER -WSW /1 ^ r 29,1966 i' S.F. , I E CH BASIN LINE G / SPOOL CP OLEANOUT C. y,) �PRD✓I4635-O0`tlw9{4635-DJ-SAS).DIYC 02013 SWE£TSER'ENGIN££RINGI � PROPOSED SEPTIC DESIGN FOR, DUBLIN CONSTRUCTION .LOC. LOT 3, . # � 6 i,. YARIAOUTH ROAD, TWT YAWOUTH ST=ER L?1GlhtZ=G. 203 SETUCKET ROAD "508-' P. 0. BOX 713 385-6900. SOUTH . DENNIS, MASS. 02660 v^TESEPT.' , 20, , 2013 SCALE. 20' ,LOB No, 4635;037, REV. OCT. 3, - 2013' REV' PCT., 18,` X013 - SHEET -1 _ OF 1 . C. y,) �PRD✓I4635-O0`tlw9{4635-DJ-SAS).DIYC 02013 SWE£TSER'ENGIN££RINGI �