HomeMy WebLinkAbout19 West Road - Site PlanNOTE: BLDG SEWER' TO BE RE-ROUTED FROM REAR OF DWELL. TO EXIT AT _ ELEV. SHOWN ACCESS COVERS TO WITHIN 6' OF FIN. GRADE 11.7' SYSTEM PROFILE (NOT TO SCALE) PRECAST H-10 sig (T+'rd 4"OSCH40 PVC _ PIPES LEVEL 1ST 2' '# 10" 1500 GAL H-10 14" g, 5' TEE SEPTIC TANK TEE $ g' GAS BAFFLE •. . o,°,o�o°opo 4' UO. LEVEL (ACME OR EQUAL) �o�oo°,°°�°o�00000° I WATER -TEST D'BOX FOR LEVELNESS 6" CRUSHED STONE OR MECHANICAL COMPACTION. (15.221- [23) ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPAR4BLE MEANS FOR FUTURE LOCATION. PROVIDE INSPECTION PORTS TO WITHIN 3- OF FINISH GRADE 27 SLOPE REQUIRED OVER SYSTEM 32 QUICK4 UNITS (NO STONE PROPOSED) ( R SLOPE) (--Lx SLOPE) ( 7 SLOPE) MIN. LEACHING FOUNDATION- 15' - SEPTIC TANK 12' D' BOX 6' FACIL *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM LEGEND- EGEND99- 99- EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. --[99]-- PROPOSED CONTOUR 1991 PROPOSED SPOT EL. TH1 TEST HOLE 2� SLOPE OF GROUND UTILITY POLE FIRE HYDRANT NOTE NOT All SYMBOLS MAY APPEAR IN DRAWING TEST HOLE LOGS ENGINEER: DANIEL E. GONSALVES, SE #13587 WITNESS: AMY VON HONE, RS DATE: 5/28/14 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS ELEV. 1 ELEV. 0., Q 9.0' 0„ I 9_0' - A LS 1OYR 3/2 7" B LS 27" 1OYR 5/8 6.8' C PERC MS 2.5Y 6/6 WATER 1.2' A LS - 1OYR 3/2 7" B LS 27" 1 OYR 5/8 6.8' C MS 2.5Y 6/6 WATER 1.2' - v - 126" -1.5 126" -1.5' GROUNDWATER ENCOUNTERED 94" DOWN DCE #00-208 TRIPLE OAKS SPRUCE 2.57 ITY GROUNDWATER ADJ. DATA: WELL: MIW 29 ZONE: A ADJUSTMENT: 1.7' (MAY) NOTE: HOMEOWNER DESIRES TO RETAIN TREES (ONE P. PINE WALL NEED REMOVING IN AREA OF SOIL REMOVAL) (BENCHMARK COR CONCRETE PATIO EL. = 11.4' r PITCH\T PINE I G. SEWER TO BE RE-ROUTED TO EXIT AT ELEV. SHOWN 0.96 �. PROP. ROOF DECK x 1 1 .78 EXIST. DWELLING TOP FNDN. = 11.7' FIRST FL. ELEV. 12.5' EXIST. DECK (REMOVE) 2�1 4 ST 0 �- x12.24 1 LOT AREA 11,346± SF 2.25 5' ADJUSTED GW EL. 2.9' i NOTES 1. DATUM IS NAVD'88 2. MUNICIPAL WATER IS AVAILABLE 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO H- 10 I 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS. ENVIRONMENTAL CODE TITLE V. 1 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. B. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. I 10 CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO LOCUS MAP COMMENCEMENT OF WORK. 11. EXISTING LEACHING FACIUTY SHALL BE PUMPED AND NOT TO SCALE REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. ASSESSORS MAP 22 PARCEL 34 12. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE LOCUS IS WITHIN FEMA FLOOD ZONE X AS REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. SHOWN ON COMMUNITY PANEL #25001CO569J DATED 7/16/2014 SYSTEM DESIGN: 5' REMOVAL OF UNSUITABLE SOIL REQUIRED AROUND PERIMETER OF LEACHING FACILITY, GARBAGE DISPOSER IS NOT ALLOWED DOWN TO SUITABLE SOIL LAYER. REPLACE NTH CLEAN MED. SAND, TO MEET DESIGN FLOW: EXISTING 3 BEDROOM PROPOSED 4 SPECIFICATIONS OF 310 CMR 15.255(3) 40 GPD \ CAUTION: 8.76 EXCAVATIO 1 9.1 P ES < o 9.64 � 0 P\s � .PINES x 1 51 \/ �ER /X\ /1'68 / / \ 1_>0� xlo.ed 1.29 Scale: 1"= 20' 0 10 20 30 40 50 FEET 00 4 BEDROOMS ®110 GPD = 4 USE A 440 GPD DESIGN FLOW GASLINE IN AREA OF SEPTIC TANK: 440 GPD (2) = 880 N USE A 1500 GAL. SEPTIC TANK LEACHING: 4.72 SF/LF x 4' LENGTH = 18.88 SF PER STD. QUICK 4 UNIT 440 GPD/0.74 GPD/SF = 595 SF LEACHING REQ'D 595 SF/18.88 SF/UNIT = 31.5 UNITS THEREFORE, USE GRAVELLESS SYSTEM OF (32) STANDARD QUICK4 UNITS IN FIELD CONFIGURATION \ SHOWN 32 UNITS x 18.88 SF/UNIT = 604 SF > 446 SF 604 SF (0.74 GPD/SF) = 447 GPD (OK) PROP. SECOND STORY OVER PORTION OF ` DWELLING (HATCHED AREA) ADDITIONS _.. "ii Hcalth Departm, at Bate _���„ _...�„sSgcy �o� DANIEL ,Fo DAN11ELA. OJALA OJALA Nm o CIVIL ^ No. 40980 5�I TF SGlSE UR Z I 1 S CONAL E -11.11 DATE DANIEL A. OJALA, P.E., I P.L.S. MA APPROVED DATE BOARD OF HEALTH TITLE 5 SITE PLAN OF 19 WEST ROAD WEST YARMOUTH PREPARED FOR SUSAN BRITA DATE: MAY 28, 2014 I off 508-362-4541 fax 508-362-9880 downcape.com down cope engineering, int. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 00-208 BRITA.DWG Route P c zt 0 c �P s, Locus 0 e h Lewis r Bay Rod/o DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO LOCUS MAP COMMENCEMENT OF WORK. 11. EXISTING LEACHING FACIUTY SHALL BE PUMPED AND NOT TO SCALE REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. ASSESSORS MAP 22 PARCEL 34 12. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE LOCUS IS WITHIN FEMA FLOOD ZONE X AS REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. SHOWN ON COMMUNITY PANEL #25001CO569J DATED 7/16/2014 SYSTEM DESIGN: 5' REMOVAL OF UNSUITABLE SOIL REQUIRED AROUND PERIMETER OF LEACHING FACILITY, GARBAGE DISPOSER IS NOT ALLOWED DOWN TO SUITABLE SOIL LAYER. REPLACE NTH CLEAN MED. SAND, TO MEET DESIGN FLOW: EXISTING 3 BEDROOM PROPOSED 4 SPECIFICATIONS OF 310 CMR 15.255(3) 40 GPD \ CAUTION: 8.76 EXCAVATIO 1 9.1 P ES < o 9.64 � 0 P\s � .PINES x 1 51 \/ �ER /X\ /1'68 / / \ 1_>0� xlo.ed 1.29 Scale: 1"= 20' 0 10 20 30 40 50 FEET 00 4 BEDROOMS ®110 GPD = 4 USE A 440 GPD DESIGN FLOW GASLINE IN AREA OF SEPTIC TANK: 440 GPD (2) = 880 N USE A 1500 GAL. SEPTIC TANK LEACHING: 4.72 SF/LF x 4' LENGTH = 18.88 SF PER STD. QUICK 4 UNIT 440 GPD/0.74 GPD/SF = 595 SF LEACHING REQ'D 595 SF/18.88 SF/UNIT = 31.5 UNITS THEREFORE, USE GRAVELLESS SYSTEM OF (32) STANDARD QUICK4 UNITS IN FIELD CONFIGURATION \ SHOWN 32 UNITS x 18.88 SF/UNIT = 604 SF > 446 SF 604 SF (0.74 GPD/SF) = 447 GPD (OK) PROP. SECOND STORY OVER PORTION OF ` DWELLING (HATCHED AREA) ADDITIONS _.. "ii Hcalth Departm, at Bate _���„ _...�„sSgcy �o� DANIEL ,Fo DAN11ELA. OJALA OJALA Nm o CIVIL ^ No. 40980 5�I TF SGlSE UR Z I 1 S CONAL E -11.11 DATE DANIEL A. OJALA, P.E., I P.L.S. MA APPROVED DATE BOARD OF HEALTH TITLE 5 SITE PLAN OF 19 WEST ROAD WEST YARMOUTH PREPARED FOR SUSAN BRITA DATE: MAY 28, 2014 I off 508-362-4541 fax 508-362-9880 downcape.com down cope engineering, int. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 00-208 BRITA.DWG