Loading...
HomeMy WebLinkAboutOff West Yarmouth Road - Sheet IndexFBI GE SPECIFICATIONS LAMINATED COLUMNS - NO. 1 OR BETTER SOUTHERN YELLOW PINE NAIL LAMINATED 3 MEMBER S4S COLUMNS USED IN MORTON BUILDINGS ARE PRESSURE TREATED BELOW GRADE TO A RETENTION OF .8 POUNDS PER CUBIC FOOT WITH CHROMATED COPPER ARSENATE TYPE III, OXIDE TYPE, AS LISTED IN FEDERAL SPECIFICATION TT -W -571J. THE TREATED PORTION OF THE COLUMN EMBEDDED IN GROUND SHALL BE LAMINATED WITH STAINLESS STEEL NAILS. FOOTINGS AND ANCHORAGE - COLUMN HOLES ARE DUG 4 FEET DEEP MIN. DEPTH BELOW GRADE AND READY -MIX CONCRETE PADS OR DRY CONCRETE MIX PADS ARE POURED IN PLACE (NOTE PLANS FOR SIZE & TYPE). TWO GALVANIZED STEEL BASE ANCHORS ARE PLACED 1" FROM BOTTOM OF COLUMN OR 1/2" GALVANIZED STEEL ROD PLACED 2 1/2" FROM BOTTOM OF COLUMN.( SEE SECTION )ADDITIONAL CONCRETE IS MIX POURED AROUND BASE OF COLUMN THEN BACKFILLED WITH SOIL AND COMPACTED AT 8" INTERVALS. SPLASHBOARDS - SPLASHBOARDS ARE NO. 2 OR BETTER SOUTHERN YELLOW PINE 2"x8" S2S AND CENTER MATCHED, PRESSURE TREATED TO NET RETENTION OF .6 POUNDS PER CUBIC FOOT WITH CHROMATED COPPER ARSENATE TYPE III, OXIDE TYPE, IN ACCORDANCE WITH AMERICAN WOOD PRESERVERS' ASSOCIATION SPECIFICATION C2. ONE ROW IS FURNISHED FOR BUILDING ON A LEVEL SITE_ FRAMING LUMBER -SIDE NAILERS ARE 2"x4" S4S OR 2"x6" SPF NO.2 OR BETTER SPACED APPROXIMATELY 30" O.C. WITH ALL JOINTS STAGGERED AT ATTACHMENT TO COLUMNS. ROOF PURLINS ARE 2"x4" S4S NO. 2 OR BETTER ON EDGE SPACED APPROXIMATELY 24" O.C. ALL OTHER FRAMING LUMBER IS NO. 2 OR BETTER.( SEE SECTION ) ROOF TRUSSES - FACTORY ASSEMBLED WITH 18 OR 20 GAUGE GALVANIZED STEEL TRUSS PLATES AS REQUIRED AND KILN DRIED LUMBER AS SPECIFIED. IN -PLANT QUALITY CONTROL INSPECTION IS CONDUCTED UNDER THE AUSPICES OF THE TPI INSPECTION BUREAU. TRUSSES ARE DESIGNED IN ACCORDANCE WITH CURRENT STANDARDS AND SPECIFICATIONS FOR THE STATED LOADING. SIDING PANELS (KYNAR 500/HYLAR 5000) -0.019" MIN., G90 GALVANIZED OR AZ55 GALVALUME, WITH AN ADDITIONAL BAKED—ON KYNAR 500/HYLAR 5000 FINISH. PAINT IS NOM. 1 MIL THICK ON EXTERIOR. ROOFING PANELS (FLUOROFLEX 2000 (TM)) —0.019" MIN., AZ55 GALVALUME WITH AN ADDITIONAL BAKED—ON THICK POLYURETHANE PRIMER AND KYNAR 500/HYLAR 5000 TOPCOAT ry WITH A TOTAL MINIMUM PAINT THICKNESS OF 2 MILS. TRIM —DIE—FORMED TRIM OF 0.019" MIN., G90 GALVANIZED OR AZ55 GALVALUME STEEL ON GABLES, RIDGES, CORNERS, BASE, WINDOWS, AND DOORS WITH SAME FINISH AS ROOFING OR SIDING PANELS. GUTTER - 5" K -STYLE, .030 HIGH TENSILE ALUMINUM GUTTER, KYNAR 500/HYLAR 5000 FINISH TO MATCH TRIM, ON BOTH SIDES OF THE BUILDING. ADDITIONAL NOTES 1.) ALL PLOT PLANS AND RELATED DETAILS SHALL BE PROVIDED BY OWNER UNLESS INCORPORATED AS PART OF THESE DRAWINGS. i 2.) ALL INTERIOR PARTITIONS AND ROOM FINISHES IF NOT INCLUDED WITH THESE DRAWINGS SHALL BE PROVIDED BY OWNER. STANDARD FINISHES SHALL HAVE LESS THAN 200 FLAME SPREAD RATING AS REQUIRED BY ASTM E84 FOR ORDINARY CONDITIONS AND 25 OR LESS FOR EXITS, PASSAGEWAYS, AND CORRIDORS. 3.) FLOOR COVERINGS JUDGED TO REPRESENT AN UNUSUAL HAZARD SHALL MEET THE SAME TESTING PROCEDURES AS REQUIRED FOR WALL AND CEILING FINISHES. 4.) MORTON BUILDINGS GENERAL SPECIFICATIONS APPLY UNLESS INDICATED DIFFERENTLY ON SPECIFIC JOB DRAWINGS OR SUPPLEMENTAL INFORMATION. 5.) KYNAR 500 IS A REGISTERED TRADEMARK OF ELF ATOCHEM NORTH AMERICA, HYLAR 5000 IS A TRADEMARK OF AUSIMONT, USA. CS2x4FK 2-96 BUILDING SHEET LUMBER SPECIFICATIONS — 1991 NDS DESIGN CRITERIA INDEX BENDING VALUE Fb USE GROUP U CONSTRUCTION TYPE 513 LIVE ROOF LOAD DESIGN 25 P.S.F. WIND LOAD 90 M.P.H. FLOOR LOAD 125 P.S.F. FLOOR AREA1 2,520 SO, FT. ConstrLICENSE Effe uction Super, dive Date 11.30.91 Lie. # Brunson31 C , GeofreY F. 044694 'lid leboro estreet A 02346 SHEET LUMBER SPECIFICATIONS — 1991 NDS DATE: SIZE INDEX BENDING VALUE Fb SHEET DESCRIPTION 1 OF 3 SPECIFICATIONS & SHEET INDEX 2 OF 3 COLUMN PLAN ELEVATIONS & SECTION 3 OF 3 TRUSS DRAWING ConstrLICENSE Effe uction Super, dive Date 11.30.91 Lie. # Brunson31 C , GeofreY F. 044694 'lid leboro estreet A 02346 NOTE: HIGHER GRADE MATERIAL REQUIRED AS NOTED ON PLANS. I HEREBY CERTIFY THAT THE STRUCTURAL DESIGN FOR THIS BUILDING WAS PREPARED,"E OR UNDER MY DIRECT SUPERVISION AND TH I A DULY GIS ;ED PROFESSIONAL ENGINEER. RONALD L. SUTTON, P.E. MICHAEL L. McCORMICK P.E. DATE: -2-4-28 REG. # I HEREBY CERTIFY THAT THE ARCHITECTURAL DESIGN FOR THIS BUILDING WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY ,E i6,;R LICENSED ARCHITECT. _ t ,e Y " WA NE N N�OO N ARCHI�EGT" EOgA6 DATE: REG # OFFICE: NORTON, MA JOB NO. 122-1171 F - III *I nC% V 0 0 z I DRAWN TYPICAL LUMBER SPECIFICATIONS — 1991 NDS DATE: SIZE DESCRIPTION BENDING VALUE Fb SCOTT S. 2"x4" NO.1&2 SPF 1313 PSI DATE: 2"x4" 2100f MSR SPF 2100 PSI REVISEDREVISED 2"x6" NO.1&2 SPF 1138 PSI 2"x6"' N0 1 SYP 1650 PSI 2"x8" NO. 1 SYP 1500 PSI 2"x10" NO. 1 SYP 1300 PSI 2"x12" NO. 1 SYP 1250 PSI ALL 1950f MSR SYP 1950 PSI 1 1 2"x16" LAMINATED VENEER LUMBER 2800 PSI 3 1 2"x15" GLU-LAM 1650 PSI 51 4"x161 2 GLU-LAM 2400 PSI 51 4'x191 2' GLU-LAM 2400 PSI NOTE: HIGHER GRADE MATERIAL REQUIRED AS NOTED ON PLANS. I HEREBY CERTIFY THAT THE STRUCTURAL DESIGN FOR THIS BUILDING WAS PREPARED,"E OR UNDER MY DIRECT SUPERVISION AND TH I A DULY GIS ;ED PROFESSIONAL ENGINEER. RONALD L. SUTTON, P.E. MICHAEL L. McCORMICK P.E. DATE: -2-4-28 REG. # I HEREBY CERTIFY THAT THE ARCHITECTURAL DESIGN FOR THIS BUILDING WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY ,E i6,;R LICENSED ARCHITECT. _ t ,e Y " WA NE N N�OO N ARCHI�EGT" EOgA6 DATE: REG # OFFICE: NORTON, MA JOB NO. 122-1171 F - III *I nC% V 0 0 z I DRAWN BY: STEPH 841 DATE: 04-09-98 CHECKED BY: SCOTT S. DATE: 4-20-98 REVISED DATE: REVISEDADATE: REVISEDREVISED SCALE: _ SHEET NO. 1 of 3