Loading...
HomeMy WebLinkAbout938 West Yarmouth Road - Sewage Plan)N VEL COVER WITH RISER 6 " BELOW GRADE PIPE TO BE LEVEL �l r -FOR 2' OUT OF D -BOX 6.83 17:0 -6" COMPACT STONE OR COMPACTED BASE COVER WITH RISER MINIMUM 9" COVER EXCLUDING TOPSOIL 0 17.5 0 0 0 0 0 0 0 0 0 0 0 16.5 BOTTOM ® 14.5 2� 500 GALLON H-10 DRYWELLS WITH 3/4 -1 1/2 OF DOUBLE WASHED STONEON 3' ON ENDS AND 2' BETWEEN DRYWELLS AND 3' 10" SIDES 12.5' X 25' 5.0' 9.5 EL BOTTOM OF TEST HOLE ------------ LIVING BED LIVNG BATH WALK OUT BASEMENT 'KITCHEN � o I FAMILY _TY _ W ~ BED KITCHEN ROOM a a BED'rn IST FLOOR WITH PROPOSED EDITION ------ ' MOT TO SCALE) -22.0 EL PUMP OUT AND REMOVE EXISTING LEACHING PIT (SEE NOTE #2) 21.0 EL I PUMP OUT AND REMOVE EXISTING CESSPOOL (SEE NOTE, #11) PROPOSED DRY WELL 1.0 NOTES 1. PUMP OUT AND REMOVE EXISTING CESSPOOL AND ANY CONTAIMINATED SOILS WITHIN 5' OF S.A.S.. 2. PUMP OUT AND REMOVE EXISTING LEACHING PIT AND ANY CONTAMINATED SOILS WITHIN 5' OF S.A.S.. 3. EXISTING SEPTIC TANK TO BE REPLACED WITH NEW 1500 GALION MONO H-10 TANK 4. PLAN REFERENCE: CERTIFIED FOUNDATION PLAN OF 938 WEST YARMOUTH ROAD, YARMOUTH, MA, PREPARED BY WELLER & ASSOCIATES, DATED 8-19-09. DESIGN DATA DAILY FLOW (3) BEDROOMS X 110 GPD = 330 GPD NOT DESIGNED FOR GARGABE GRINDER SEPTIC TANK: 330 GPD X 2007 = 660 GPD USE: NEW 1500 GALLON H-10 MONO SEPTIC TANK USE: 6 HOLE H-20 D -BOX SOIL ABSORPTION SYSTEM: USE: (2) 500 GALLON H-10 DRYWELLS WITH DOUBLE WASHED STONE 3' ON ENDS AND 2' BETWEEN DRYWELLS AND 3' 10" ON SIDES. SIDEWALL AREA: 75' X 2' X 0.74 = 111.0 GPD BOTTOM AREA: 12.5' X 25' X 0.74 = 231.25 GPD TOTAL AREA: = 342.25 GPD GENERAL NOTES 1. CONTRACTOR TO BE RESPONSIBLE FOR THE LOCATION OF ALL UTILITIES, ABOVE & UNDERGROUND, PRIOR TO ANY EXCAVATION OR CONSTRUCTION. 2. SEPTIC SYSTEM IS TO BE INSTALLED IN COMPLIANCE WITH 310 CMR 15.00:TITLE V. 3. PROPERTY LINE INFORMATION IS ONLY APPROXIMATE. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM UPGRADE. J. O'LOUGHLIN INC. WILL NOT ASSUME ANY LIABILITY FOR USES OF THIS PLAN OTHER THAN ITS INTENDED USE. 4. DESIGNER AND TOWN BOH AGENT TO INSPECT & CERTIFY OVER - DIG, WHEN REQUIRED BY PLAN, AND FINAL INSPECTION BEFORE BACKFILL. 5. CONTRACTOR TO PROVIDE 48 HOUR NOTICE FOR ANY REQUIRED INSPECTIONS. 6. THIS SYSTEM IS NOT DESIGNED FOR THE USE OF A GARBAGE DISPOSAL. 7. THE TOP OF ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC MARKING TAPE OR A COMPARABLE MEANS IN ORDER TO LOCATE THEM ONCE BURIED. 8. IF SOILS ARE FOUND UNSUITABLE OR DIFFERING FROM THOSE FOUND IN SOIL LOG CONTACT DESIGNER AND THE BOARD OF HEALTH. 9. IF UNSUITABLE"MATERIAL IS FOUND IN THE PRIMARY OR THE RESERVE OF THE S.A.S. AN OVERDIG REQUIRING CLEAN GRANULAR SAND MEETING 310CMR 15.255(3) SHOULD BE USED AS FILL MATERIAL, 5' AROUND AND UNDER S.A.S.. 10. ALL 4" PIPE CONNECTION AT SEPTIC TANK AND D -BOX SHALL BE MORTARED IN PLACE. IF USING 18" PLASTIC RISER PIPES, THESE TOO SHALL BE MORTARED IN PLACE. 23" 126" 6A 6A Z e 2 A S Y (N � ���EAIHER LANE y HOUSE RD' ' �1 HAKER 0 W141TE ROCK RD. F TEST HOLE LOG DATE: 8/25/09 TEST BY: MIKE O'LOUGHLIN WITNESS: AMY VON HONE TEST HOLE # 1 TEST HOLE # 2 20.0 EL 0" AP LOAMY SAND 10YR 4/2 BW LOAMY SAND 10YR 5/8 BOTTOM OF PERK ® 40" EL 15.58 Cl FINE MEDIUM SAND 2.5Y 6/6 19.5 EL 6" 18.0 EL 9.5 EL 23" 126" BW LOAMY SAND 10YR 5/8 Cl FINE MEDIUM SAND 2.5Y 6/6 WATER NOT ENCOUNTERED WATER NOT ENCOUNTERED * N. W. SIDE OF TEST HOLE DISTURBED SOILS PERK RATE > 2 MIN PER INCH \Sl .y;f V!.rllh Departme . ( _�ft Date HEALTH AGENT APPROVAL SEWAGE PLAN LOCATION: 938 WEST YARMOUTH ROAD PREPARED FOR: MATTHEW AND STACEY HARRISON SC ALE: 1 = 20 DATE: OCTOBER 15, 2009 JOB NUMBER: 09-224 REVISION: MAP: 115 PARCEL: 40 J. O'LOUGHLIN INC. 714 MAIN STREET, YARMOUTH PORT, MA 02675 (508) 362-4942 20.5 EL 20.0 EL 18.6 EL 10.05 EL DATE DRAWN BY: MARYBETH MCKENZIE REGISTERED SANITAPIIAI`�-7 322 b - ( 5 -6A