Loading...
HomeMy WebLinkAbout353 Whites Path - Site Plan 3TD / /F\ --A I I I I m MID --CAPE HIGHWAY LOCUS MAP ASSESSOR'S MAP 110, PARCEL 8 ' ZONING DISTRICTS, B3 6 APD MIN FRONTAGE - 100' MIN LOT AREA - 40000 S.F. MAX BUILDING HEIGHT - 35' SETBACKS: FRONT - 30'. SIDE - !0', REAR - 30' MAXIMUM BUILDING COVERAGE - 35xCATCH BASIN �� p A T H MAXIMUM LOT COVERAGE - 70x WHEN ARTIFICIAL RECHARGE 210. srte Ois uce ®RIM -98,52 98.7 OF EXCESS RUNOFF IS PROVIDED. FLOOD ZONE X. PANEL 25001 CO583J DATED 7116114 BM. CATCH BASIN9. - - - - - - - - _ SITE o srAace - � � \ 99.6\ \ AREA CALCULATIONS: +99.1 -0-99.7 q \ \ 96.5 99. 8 _ 99. 6 -,NP. _ � v \ / � +\101\ 6 \+ -09. 7 PROPOSED �L ARRSSCAPED BEG - - _ 100 S PROPOSED.-CATOr P TOTAL LOT AREA - 27.810± S.F. - 0.64± ACRES = �AROUN4 SIGN PLANTED WITH BASIN RIM -100.5 TOTAL BUILDING AREA - 5.000± S.F. - 18.09 OF SITE NATIVE SHRUBS AND IDR TOTAL PARKING AND DRIVE - 13.3821 S.F. - 48.1% OF SITE ORNAMENTAL GRASSES,- N 84�7r25 E `\ `\ Op • - `\ CoQ +99.5 TOTAL IMPERVIOUS AREA - 18.382± S.F. - 66. lx OF SITE _ _ - `�� TWo POSTED - - - - ;0l.6 11WI TE 5/GN ' ,02 5 PROPOSED CATCH \ \ PARKING CALCULATIONS: WITH RED AND ) 20 BUFFER BASIN AIM -IQ _ \\ BLACK LETTER`NG o 1301.4.91 INDUSTRIAL USE. 2000 SF / 200 SF PER PERSON - !0 PEOPLE PRoPosED LAWN`\ ---- 10 \\ STORAGE USE. 3000 SF / 300 SF PER PERSON - l0 PEOPLE = Z4 \ TOTAL OCCUPANCY LOAD - 20 PEOPLE `2' PROPOSED 1 O 1 P { WELL I •( `'\ I SPACE/2 OCCUPANTS FOR BUISINESS/INDUSTRIAL- l0 SPACES REQUIRED _ , z eR r• 2-1000 GAL PITS -% TOTAL SPACES PROVIDED - l0 SPACES / ' \ /xI -',�-- oD! W/3' STONE AROUND 44' - 102.3 I' 102.2 \ I m PROPOSED+ 02.2 \ II LIGHT (TYP) �1 I 02.2 +102.2 1 � \Ory --�I lol.9� GarE m ,02.1 GENERAL NOTES: 11 ll +101.9 \ n I. PROPERTY LINE INFORMATION WAS COMPILED FROM \ o A AVAILABLE PLANS AND DEEDS OF RECORD AND DOES co NOT REPRESENT AN ACTUAL ON THE GROUND SURVEY. \ � a 2. VERTICAL DATUM 15 ASSUMED. FOR BENCH MARKSK \ PROPOSED BUILDING H SET, SEE SITE PLAN. THREE BAYS _ J. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEED RESTRICTIONS OR ZONING REGULATIONS. IT SHALL REMAIN THE CLIENTS RESPONSIBILITY TO OBTAIN ALL PERMITS, SPECIAL PERMITS. VARIANCES ETC. FOR THIS PROJECT. 4. IT SHALL REMAIN THE CLIENT'S RESPONSIBILITY TO HAVE THE PROPOSED BUILDING FOUNDATION DESIGNED TO ACCOUNT FOR THE EXISTING GRADE AND SOIL CONDITIONS AT THE LOCATION OF THE PROPOSED BUILDING. 5. ALL STORMWATER RUNOFF FROM IMPERVIOUS AREAS TO BE CONTAINED ON SITE. 6. ALL CONSTRUCTION METHODS AND MATERIALS AND MAINTENANCE OF THE SEPTIC SYSTEM SHALL CONFORM TO MASS. D.E.P. TITLE 5 AND LOCAL BOARD OF HEALTH REGULATIONS. 7. ALL SEPTIC SYSTEM COMPONENTS LOCATED UNDER AREAS SUBJECT TO VEHICULAR TRAFFIC OR GREATER THAN 3' IN DEPTH SHALL BE CAPABLE OF WITH- STANDING H-20 WHEEL LOADS. 8. ALL SEWER PIPE SHALL BE SCHEDULE 40 OR APPROVED EQUAL. 9. SEPTIC TANK AND D -BOX SHALL BE REINFORCED PRECAST CONCRETE AND WATERTIGHT. 10. D -BOX IS TO BE WATER TESTED TO CHECK FOR LEVEL. 11. BEFORE CONSTRUCTION CALL -DIG-SAFE'. 1 -888 -DIG -SAFE AND THE LOCAL WATER DEPT. FOR LOCATION OF UNDERGROUND UTILITIES. EXISTING BUILDING + 102.2 FL- 103-0 X11 SII+102 HOLDING f� TANK HOLDING TANK NO TES : 1. HOLDING TANK SHALL 8E H-20 PRECAST CONCRETE + 102. 5 PIT DATA a 0 m a T 50' A m PROPOSED LIGHT (TYR) 0•V DO�A'9AOUT 12' PE O 2-8' DIAM x 6' DEEP PITS +10f.5 PROPOSED PAVED 0 102.9 W/4' STONE AROUND pARKINO AREA PROPOSED 3' CALIPER ' - - TREE AT 20' OC IN BUFFER \ ALTERNATE SPRUCE AND BIRCH I .a T PROPOSED CATCY ) a m. BASIN RIM,4e2.0 A 110'x 20' PROPOSED 3' CALIPER i ) (TYR) TREE AT 20' OC IN BUFFER ALTERNATE SPRUCE AND BIRCH 1500 GALLON 2 COMPARTMENT SEPTIC TANK Q';. + 103.3 102. A +102.9/' D2 LOT 5 j \\\ +ra2.e I 11• 27.810+ S.F. _ I D -Box O) .... PROPOSED GRAVEL- y- -------- STORAGE AREA - - 2-500 GALLON::': LEACHING CHAMBERS W/4STONE AROUND TPe2 VENT 11 12.8'...1 / - - - - - - STONE LINED / ORAINAOE SWALE 10' TPZI y', a /• 1L - --/_,_-{ p6.76 PROPOSED 3' CALIPER---' - • Y S IO' BUFF Ea R TREE AT 20' GC IN BUFFER 4.41 I +103.4 I/ -23;30 vw ALTERNATE SPRUCE AND BIPCH 104.6 / ST ---------------- +106.0 --------- I / II // +106.0 RA ROAD +104.1 ACCESS COVERS MUST f� INVERT ELEVATIONS: HOLDING TANK NO TES : 1. HOLDING TANK SHALL 8E H-20 PRECAST CONCRETE DESIGN CRITERIA: PIT DATA a 9" MINIMUM. 6' CRUSHED STONE TO BE LOCATED INSIDE OF THRU BUILDING IN ACCORDANCE WITH BE TO FINISH GRADEINVERT 3' MAXIMUM COVER AT BUILDING: 102.0 DESIGN FLOW: FIRST 2' TO FROM ACME PRECAST CO. AUDIO AND VISUAL ALARMS WITH INVERT IN SEPTIC TANK: 100.65 FACTORY. INDUSTRIAL AND STORAGE USE BE LEVEL MIN 2' OF PEASTONE INVERT OUT SEPTIC TANK. 100.4 3 BAYS AT 5 PEOPLE/BAY x 15 GPD - 225 GPD THE BOARD OF HEALTH PROPOSED SPOT ELEVATION INVERT IN DIST. BOX: 100.27 /000 SF OFFICE x 75 GPD/I000 SF - 75 GPD ir 3/4" - I I/2" DIA. INVERT OUT DIST. BOX: 100.1 TOTAL FLOW - 300 GPD 0 0 e 100.4 I p,/ 2' H-20 4" DOUBLE WASHED STONE INVERT IN LEACH CHAMBER: 100.0 __-ALL INLET. VENT AND . Das BAFFL !00.27 $ 100.0 0 98.0 FILL FILL 98.0 SEPTIC TANK REQUIRED: 2 COMPARTMENT low 0 soo O 2, A PUMPING CONTRACT WITH A LICENSED SEPTIC BOTTOM OF LEACH CHAMBER: 28' - - - - - - - - - - - - - -- IOf,7 300 G.P.D. X 200% - 600 GAL. 1st COMP 3 OUTLET 2-500 GAL LEACHING CHAMBERS r PROVIDED WI TH FACTORY ADJUSTED GROUND WATER: N/A G.P.O. X /00% - 300 GAL. 2nd COMP .0300 D -BOX W/4' STONE AROUND. 12.8'1 x 25'1 x 2'd OBSERVED GROUND WATER: N/A SEPTIC TANK PROVIDED: 1500 GAL. 2 COMP 1500 GAL H-20 2 COMPARTMENT H-20 BOTTOM OF TEST HOLE #1: 94.0 INSTALLATION. SEPTIC TANK 6" CRUSHED STONE OR SOIL ABSORPTION SYSTEM REQUIRED: COMPACTED BASE C I MEDIUM IOYR C I MED! LSA IOYR DESIGN PERC RATE ( 5 MIN/INCH PROFILE : Nor TO SCALE 3 OPERATION AND MAINTENANCE OF THIS SYSTEM SAND 7/3 SAND 7/3 SOIL TEXTURAL CLASS - I EFFLUENT LOADING RATE - 0.74 GPD/SF 300 GPD / 0.74 GPD/SF - 405 S.F. REQUIRED PROVIDED: 2-500 GAL LEACHING CHAMBERS W/4' STONE AROUND. A-471 S.F. 471 S.F. x 0.74 - 348 G.P.D. 32" DIAM HEAVY DUTY TOTAL NITROGEN LOADING ALLOWED BASED ON LOT CAST IRON GASKETED COVERS SIZE - 27.810 S.F.110.000 X 1/0 - 305 GPD TO FINISH GRADE, NITROGEN LOADING PROPOSED - 300 GPD OK 4 •- f� VENT TO BE ROUTED HOLDING TANK NO TES : 1. HOLDING TANK SHALL 8E H-20 PRECAST CONCRETE SOIL TEST PIT DATA a -W- 6' CRUSHED STONE TO BE LOCATED INSIDE OF THRU BUILDING IN ACCORDANCE WITH NON -HAZARDOUS 1500 GALLON WASTE WATER TANK INDICATES PERCOLATION y INDICATES OBSERVED GAS LINE ® �1 STATE AND tocat FROM ACME PRECAST CO. AUDIO AND VISUAL ALARMS WITH TEST _ GROUNDWATER H 20 PRECAST NON -HAZARDOUS 1500 GALLON -T- PLUMBING CODES FLOAT SWITCH SET AT #/. INTERIOR TANK AT 75X CAPACITY EXISTING SPOT ELEVATION OF THE HOLDING TANK TO THE BOARD OF HEALTH PROPOSED SPOT ELEVATION WASTE WATER TANK BY ACME PRECAST CO. AND #2: BETWEEN THE TWO TANKS AS CLOSE TO THE BOTTOM TP =I ry •2 AND MASS DEP. AS POSSIBLE. 0" HORIZON TEXTURE COLOR 104.0 0' HORIZON TEXTURE COLOR 104.0 __-ALL INLET. VENT AND FILL FILL - ELECTRICAL HOLES TO BE 2, A PUMPING CONTRACT WITH A LICENSED SEPTIC J2' ---'---"-"-"" 101.3 28' - - - - - - - - - - - - - -- IOf,7 'n ^ PROVIDED WI TH FACTORY CONTRACTOR IS REQUIRED FOR THIS HOLDING TANK PERC RATE: ( 2 MIN/INCH INDUSTRIAL WASTEWATER 3 xsx "PACITY INSTALLED BOOTS. HOLDING TANK INSTALLATION. °EAX C I MEDIUM IOYR C I MED! LSA IOYR DETECTION DEVISE 3 OPERATION AND MAINTENANCE OF THIS SYSTEM SAND 7/3 SAND 7/3 4 •- REQUIRES THAT THE TANK BE PUMPED WHEN THE HIGH ■ CONCRETE BOUND FOUND WATER ALARM SOUNDS (75x CAPACITY). CONTROL PANEL -W- 6' CRUSHED STONE TO BE LOCATED INSIDE OF BUILDING. so" OR COMPACTED BASE -G-- GAS LINE ® CATCH BASIN 4. ENGINEER TO INSPECT AND CERTIFY THE INSTALLATION - OHW H 20 PRECAST NON -HAZARDOUS 1500 GALLON -T- UNDERGROUND TELEPHONE LINE 4-40.4 EXISTING SPOT ELEVATION OF THE HOLDING TANK TO THE BOARD OF HEALTH PROPOSED SPOT ELEVATION WASTE WATER TANK BY ACME PRECAST CO. RUNOFF DIRECTION NO NATER NO WATER 120' 94.0 1?0' 94.0 AND MASS DEP. INNER TANK IS A 1500 GALLON MONOLITHIC TANK OUTER TANK IS A 2500 GALLON H-20 TANK. DATE: , 2015 TEST BYY:: SSTEPTEPHEN HAAS TANKS TO BE FACTORY WATERPROOFED WITNESSED BY: ANY VONHON£ PERC RATE: ( 2 MIN/INCH INDUSTRIAL WASTEWATER HOLDING TANK +102.6 8" H2O CAST IRON FRAME AND GRATE CLAY BRICK LEVELING COURSE MORTARED IN PLACE 1 "DIA VENT CLEANOUT 12" HDPE PIPE TEE TO LEACHING PIT ° Z H-20 SOLID N� CATCH BASIN v H-20 CONC SLAB 6' DIAM - 1 W/12 DIA LEACH HOLE CATCH BASIN DETA IL NO SCALE 8" MIN, H2O CAST CLAY BRICK LEVELING COURSE IRON -FRAME AND COVER MORTARED IN PLACE WITH 1' VENT 4" MIN. PEASTONE TO FINISH GRADE I / /- 4 A41L POLY I/4 /rr-� 0 FROM BASIN MORTAR ALL ° rl JOINTS LEACHING 3/4"-11/2" WASHED BASIN STONE ALL AROUND (H-20) SEE PLAN SEE PLAN LEACHING BASIN DETA I L NO SCALE TYPE l-1 BITUMINOUS CONCRETE 1 1/2" BINDER COURSE. 1 1/2" TOP COURSE > > 8.5" DENSE GRADED CRUSHED STONE OR 12" GRAVEL BASE PAVEMENT DETAIL NO SCALE S l TE PLAN OF LAND 373 WH I TES PATH . MAP l l O . PARCEL 8 SOUTH YARMOUTH. MA. PREPARED FOR: ROBERT B. OUR I l l P.O. BOX 115. CENTERVILLE. MA 02632 SCALE : I - - 20 MAY 28 . 2015 REVISED: AUGUST 19, 2015 STEPHEN A. HAAS ENGINEERING, INC P.O. Box 16 South Denn i s , MA 02660 ( 508 ) 362-81.32 \t/ JOB NO: 15-002 LEGEND ■ CONCRETE BOUND FOUND ® WATER GATE -W- WATER L I NE O HYDRANT O GAS GATE -G-- GAS LINE ® CATCH BASIN --o UTILITY POLE W/ GUY WIRE - OHW OVER HEAD WIRES -T- UNDERGROUND TELEPHONE LINE 4-40.4 EXISTING SPOT ELEVATION EXISTING CONTOUR 40.40 PROPOSED SPOT ELEVATION E- RUNOFF DIRECTION 8" H2O CAST IRON FRAME AND GRATE CLAY BRICK LEVELING COURSE MORTARED IN PLACE 1 "DIA VENT CLEANOUT 12" HDPE PIPE TEE TO LEACHING PIT ° Z H-20 SOLID N� CATCH BASIN v H-20 CONC SLAB 6' DIAM - 1 W/12 DIA LEACH HOLE CATCH BASIN DETA IL NO SCALE 8" MIN, H2O CAST CLAY BRICK LEVELING COURSE IRON -FRAME AND COVER MORTARED IN PLACE WITH 1' VENT 4" MIN. PEASTONE TO FINISH GRADE I / /- 4 A41L POLY I/4 /rr-� 0 FROM BASIN MORTAR ALL ° rl JOINTS LEACHING 3/4"-11/2" WASHED BASIN STONE ALL AROUND (H-20) SEE PLAN SEE PLAN LEACHING BASIN DETA I L NO SCALE TYPE l-1 BITUMINOUS CONCRETE 1 1/2" BINDER COURSE. 1 1/2" TOP COURSE > > 8.5" DENSE GRADED CRUSHED STONE OR 12" GRAVEL BASE PAVEMENT DETAIL NO SCALE S l TE PLAN OF LAND 373 WH I TES PATH . MAP l l O . PARCEL 8 SOUTH YARMOUTH. MA. PREPARED FOR: ROBERT B. OUR I l l P.O. BOX 115. CENTERVILLE. MA 02632 SCALE : I - - 20 MAY 28 . 2015 REVISED: AUGUST 19, 2015 STEPHEN A. HAAS ENGINEERING, INC P.O. Box 16 South Denn i s , MA 02660 ( 508 ) 362-81.32 \t/ JOB NO: 15-002