HomeMy WebLinkAbout203 Willow Street - Fire Protection Basement Plan & DetailsGENERAL NOTES 1. THE SPRINKLER ROOM MUST BE PROvIDED WITH HEAT. 5. FUEL STORAGE SHALL BE LIMITED TO 5 GALLONS. 2. ALL PENETRATIONS THROUGH FIRE -RATED ASSEMBLIES AND TENANT 6, STORAGE IN EXCESS OF 5 GALLONS IS ALLOWED IF THE OWNER INSTALLS SEPARATIONS MUST 5E FIRESTOPPED IN ACCORDANCE WITH THE APPROVED HAZARDOUS MATERIAL STORAGE LOCKERS. STORAGE QUANTITY APPROPRIATE U.L. DESIGN FOR THE ASSEMBLY AND PENETRANT. SHALL NOT EXCEED 2 GALLONS PER SQUARE FOOT OF LOCKER FLOOR AREA. 3, PENDENT SPRINKLERS AND RETURN BENDS SHALL BE INSTALLED 1. THE OWNER MUST OBTAIN A PERMIT FROM THE HEAD OF THE LOCAL ON THE WARM SIDE OF THE BUILDING INSULATION AND VAPOR BARRIER. FIRE DEPARTMENT FOR FLAMI`1A5LE LIQUID STORAGE. 4. THE SPRINKLER SYSTEM DISCHARGE FOR THE FUEL STORAGE AREA 8. FUEL DISPENSING IS NOT PERMITTED. HAS BEEN INCREASED TO 0.30GPM/SF (NFPA 30 TABLE D-2.2) 1 I 6" FIRE FD CONNECTION 4 SERVICE WATER MOTOR GONG I SYSTEM A� VERIFY SPRINKLER INSTALLATION Q---- WITH LOCAL APPROVING AUTHORITY p. CHECK VALVE I L— F- 1114 — 11/ I" a .. n I � I INSPECTOR'S TEST— (SEE DETAIL) ELEC. ROOM 5" RISER UP TO FIR57 FLOOR 1 AND ATTIC 11,4" I 11/4 u 0 PITC I 21/2 i 11/4 n PITCa 1 21j2 �� I PITCH 11/4u o 11/4n 21/21, OO 0 r ----------Ir ----------- I LQCI 11 NALN!AT =Il I 2I,2 -----------J L- --J. 11/41, 11/4 u n 11/4 u ° 11,4 u ° 1114" m fI _ FUEL STORAGE AREA 5" 3„ Lu wF � 3.. 3.. 3.. m WW 0C) Lo -------------------------- Lo I --------------- �- I" N. UP TO UPRIGHT CONTAINMENT DIKE SY G.C. 3" O 5 RINKLER IN ATTIC (TYPICAL FOR 4) DRAIN W/ 1 a" „ 1 0 0 0 11,4 u HOSE 51515 al I I 51DEWALL SPRINKLER FOR M p� cq LoW COVERAGE UNDER DOOR ! ' ' � WHEN DOOR IS OPEN (TYP) i I 1 3 I ! 1 1 I h 11/4 i, = 11/4'l = 1114 -�----------------- I I 1 I I I 0 I i I I i I a x t I I ! 1 1 I 1" 1" .I 11/4 11/4u i 1 I x p � I i I 1 1 -----------------' I ------------------ I 1 I 1 I 1 1 1 I ! 1 0 i 0 0 I a i I I I I 1 i I 1 I 1 i I 1 I 1 I � 1 1 'I I " 11/4 " 1114 a ju ° -- I I I 1 1 ! f 1 ! 1 3" i I I 1 1 I 1/a'� 1 11/4n I/ n ----•-`-- '- O 0 -------------, I 1 I I 1 I I I i i i I I I 1 I , I , I R i 1 ° 11/4 " 11/4 " I/2 11/4 ° � 7 i 1 I 1 l u -------------- I � I INSPECTOR'S TEST— (SEE DETAIL) ELEC. ROOM 5" RISER UP TO FIR57 FLOOR 1 AND ATTIC 11,4" I 11/4 u 0 PITC I 21/2 i 11/4 n PITCa 1 21j2 �� I PITCH 11/4u o 11/4n 21/21, OO 0 2I,2 11/41, 11/4 u n 11/4 u m _ _ CC co 3„ Lu wF � 3.. 3.. 3.. m WW 0C) Lo Lo /2'I LOW POINT--- O W Iry DRAIN W/ rT� W f� HOSE 51515 al M p� cq LoW N 11/4 i, = 11/4'l = 1114 T- 0 - a x 21/2 11/4" 11,4 " 0 BASEMENT PLAN SCALE: 3/16" = F- 0" SPRINKLER LEGEND OCENTRAL MODEL G5 -QR PENDENT 55°F)C56KX12" ORIFICE) OCENTRAL MODEL GB -QR UPRIGHT (155°FX5.6KX1r2" ORIFICE) oCENTRAL MODEL DS -1 DRY PENDENT (155°FX5.6KX1/2" ORIFICE) ( CENTRAL MODEL G5 -QR PENDENT 4 X�( 1" RISER UP TO G5 -QR UPRIGHT �( CENTRAL MODEL DS -1 DRY PENDENT �C $ I" RISER UP TO GB -QR UPRIGHT CENTRAL 553 ATTIC SPRINKLER (212°FX5.61<X112" ORIFICE) aCENTRAL MODEL DS -I DRY SIDEWALL (155°FX5.11 ORIFICE) PIPE UP C PIPE DOWN v 50TTOM PIPE CONNECTION 21/2 " 2'/2 Ill 11/4 " fl 17/4 u INT m ATTIC SPRINKLER Lo PIPE HANGER CROSS I" PIPE MAIN DROP TEST VALVE 4 REMOVABLE PIPE SECTION TO 5E STORED IN THE SPARE SPRINKLER CABINET NOTE: THE TOTAL SYSTEM VOLUME HAS BEEN CALCULATED TO BE 456 GALLONS. THE 60 SECOND TIME LIMIT WILL NOT APPLY IF THE SYSTEM IS INSTALLED AS SHOWN. (NFPA 13 A-4-23.1) — EXTERIOR WALL PLUG UNION 45° ELL 4 SMOOTH BORE CORROSION RESISTANT OUTLET GIVING FLOW EQUAL TO THE 7 SMALLEST SPRINKLER IN THE SYSTEM. INSPECTOR'S TEST CONNECTION NO SCALE HYDRAULIC DESIGN ORDINARY HAZARD DESIGN AREA - 2040 SF MAX. AREA PER SPRINKLER - 130 SF NO. OF DESIGN SPRINKLERS - 20 DESIGN DENSITY - 0.15 GPM/SF HOSE STREAM DEMAND - 250 GPM SPRINKLER DEMAND FLOW - 434.5 GPM RESIDUAL PRESSURE REQUIRED - 45.4 PSI EXCESS RESIDUAL PRESSURE AVAILABLE - 5.6 PSI HYDRANT TEST TELT DATE - AUGUST 20, 2003 TEST HYDRANT - 55 PSI STATIC 50 PSI RESIDUAL HYCRANT FLOW - 103:^ GPM PER=CRIED 5Y: MASS FIRE PROTECTION TO SYSTEM AIR MAINTENANCE SWOGH PRIMING CUP A55EMELY PRESSURE GAUGE (TT -f=) PRESSURE SWITCH AIR COMPRESSOR -- 5" !!! TO MOTOR GONG NOTE: SLEEvE AND SEAL ALL PENETRATIONS WATERTIGHT DRY ALARM / CH= -CK v,4LvE ----TRIM W/ALARM TEST ° Gl CONNECTIONS 1 064Y 054Y MAIN ���- DRIP CUP DRAIN D 5ACK71-OW PREVENTER EQUAL TO AMES MODEL 200055 6" —roll FIRE SERVICE FLOOR RISER DETAIL NO SCALE CSeY CHECK VALVE 5" 6"X5" CCNCENTRIC REDUCER GALVANIZED SUF=CRT 5" TO FIRE DEPARTMENT CONNECTION m FA 4�USET rn¢Uc da>1' o zoa� w�= J DC7 lll� owwo 0 o m I W CC co LL Q Lu wF � � a /M. m 4�USET rn¢Uc da>1' o zoa� w�= J DC7 lll� owwo (— �" o to 03 co CC co 0 /M. m WW 0C) Lo Lo O W Iry rT� W f� al M p� cq LoW N 0 - a x U x p �w co,i DRAWING TITLE: FIRE PROTECTION EASEMENT PLAN 4 DETAILS DRAWN BY: RGV CHECKED BY: 1) AG - DATE: 01J-30-03 REVISED: PROJECT NO. 48548 SHEET Ff _ I