HomeMy WebLinkAbout203 Willow Street - Sewage Disposal System DesignI SOIL TEST PIT DATA: FEBRUARY 14, 2002 TEST PIT 12_ TEST PIT 14 GRD. EL 48.85 GRD. EL 58.02 EST. HIGH GW. _N/A EST. HIGH GW. N/A DATE: 02/14/02 TEST BY: THE BSC GROUP WITNESSED BY - AMY VON HONE PERC. RATE: 3 MIN./INCH SOIL EVALUATOR CRAIG FIELD 5" MEDIUM SAND 2.5Y 6/4 NO WATER EL = 45.0 DATE: 02/14/02 TEST BY: THE BSC GROUP WITNESSED BY - AMY VON HONE PERC. RATE: N/A MIN./INCH SOIL EVALUATOR CRAIG FIELD 2" INDICATES PERC. TEST M• INDICATES UNSUITABLE MATERIAL 156' SEPTIC TANK DETAIL: 1,500 GALLON NOT TO SCALE NOTES 1. SEPTIC TANK SHALL BE STEEL 5. INLET AND OUTLET TEES TO SHALL BE SCHED. 40 PVC. TEES SHALL BE LOCATED UNDER REINFORCED CONCRETE MANHOLE COVER FOR EASE OF SERVICING. 2. SEPTIC TANK TO WITHSTAND H-20 LOADING. 6. RECOMMENDED MANUFACTURER-ROTONDO OR 3. ALL PIPE CONNECTIONS AND CONCRETE APPROVED EQUAL CONSTRUCTION SHALL BE WATERTIGHT. 7• SEPTIC TANK SHALL BE WARRANTED BY 4. FILL ALL UNUSED KNOCKOUTS WITH MANUFACTURER. MORTAR. 2-18' DIA C.I. (600 MIN.) T� INNDER BROUGHT TO FINISH GRADE M.H. OPENING 1 ' MN. FILI11'-O' RAISE M.H W/. SEWER BRICK F 101-0' d MORTAR 1 NORMAL WATER e 3' PRECAST SEPTIC TANK 10' INLET TEE ID C) C5'-0" 4'-9' a 4'-0' MN. w 6'-2' LIQUID DEPTH woo u r ✓ _ MANHOLE COVERS 6' r 6' b` COMPACTED CRUSHED STONE PLAN VIEW 6' MIN. 3/4' TO 'e~ 1 1/2' STONE CROSS-SECTION VIEW DISTRIBUTION BOX DETAIL: NOT TO SCALE � 60 NO. OF OUTLETS 9 RAISE M.H W/ 18• DIA C.1.(BLN MIN.) MANHOLE COVER SEWER BRICK BROUGHT TO FlMMSH GRAM do MORTAR NOTES: REMOVABLE 2' WALLS COVER 1 1. DIST. BOX TO W 714STAND H-20 LOADING. ..•... 2' t 2. PROVIDE INLET TEE OR BAFFLE WHERE SLOPE OF PIPE EXCEEDS 0.08 FT./FT OR 115' T N PUMPED SYSTEM. 6' '• 9-5 OUTLETS 8' 1 3. MST TWO FEET OF PIIS OUT OF DIST. BOX TO BE LAID LEVEL. '� •$fie 4. RECOMMENDED MANUFACTURER-ROTONDO e• �• $°� $S ��et L OR APPROVED EQUAL BOTTOM ONLEVEL STABLE BASE 2 6' MIN. 3/4* TO 5. ALL PIPE CONNECTIONS AND CONCRETE CROSS-SECTION 11/2' CRUSHED CONSTRUCTION SHALL BE WATERTIGHT. STONE BASE 6 RAISE MANHOLES TO FINISH p2Al WI TH 19 log. 1 � 60 Do 7 . TH 19 log. 1 � PLAN VIEW SEWER BRICK AND MORTAR. FULL OUTER MORTAR PARGE TO PROVIDE WATER TIGHT SEAL 7. FILL ALL UNUSED KNOCKOUTS WITH MORTA LEACHING TRENCH DETAIL: NOT TO SCALE 36' MAX .COVER 4' VENT PIPE TO Y ON LA AIS FINISHED GRADE SEE DETAIL LOAM k SEED DISTURBED AREAS 4' PVC =4':EEERRF+�'M 4MZVC=- .O=e•��. CAP ENDS L1' OTlLTIY[ !RN 38' LEVEL BOTTOM �� PROFILE /2% T36' MAX. - 12' MN. COVER /- 4' MIN. LOAM & SEED 34 MN. FINISH GRADE 2' 6' 2' 6' rYP (TIP) CROSS-SECTION 2" MN. OF 1/73' TO 1/2' WASHED STONE TO 1-1/2' DOUBLE ED STONE (NO FINES) DESIGN CRITERIA: SITE BENCHMARK DESIGN FL W: 0 11 OFFICE& TAG BOLT ON urU va/ t ur Li,�r -47 3 I s 4• P �T _ SIZE OF LEACHING FACILITY PROVIDED: 4, PVC t s 47.50 - 57.50(x 'i r I� 3 2' P, LONG TRENCH iR = i- � � 5660 s 6o WIDE, 2 DEE 38' s 0 . 1=C IgE G I -H 47 00 7 3� 2.2% 47.50 BU 59 55 ,.... , 9 OUTLET I -F . g gp xC2'+2'+2')x38' 684- sEPTIc TANK DIST. Box n BOTTOM EL- ... FINISH FLOORG 01 3 OF LEACHING AREA 5 ELEV. 62.50 FINISH FLOOR 3 ; EST. HIGH GW K ® ® �, ELEV. 60.00 80 lr(yzl 684 x 0,74 GPD / SF 506 GPD 'r EASEMENT I FLR 59.55 ELEV.47.50 ,..PROVIDED INVERT ELEVATIONS: x59.23 ® �` �6 0 TOP OF SLAB 47.50 A g� 59.30 60.80 4" INVERT AT BUILDING 45.65 B :: 47.50)x LOCUS INFORMATION 4" INVERT AT SEPTIC TANK (IN) 45.25 C - CURRENT OWNER. MAxIMIuaN A. TU a :F N FTS, JR, ETAL 4" INVERT AT SEPTIC TANK (OUT) 45.00 D ' TITLE REFERENCE: DEED BOOK 2282, PAGE 15 4" INVERT AT DIST. BOX (IN) 44.95 E .. � . - . - �, •oma � w 4" INVERT AT DIST. BOX (OUT) 44.78 F 62.50 PLAN REFERENCE. PLAN BOOK 36 , PAGE 54 e , ai 1BOXe '4'PVC' I �+ � �p4 7 ® SCH. 40 ,� ASSESSORS MAP: 103 " „.... . .;... ® f TP x 56 0 56.4t t INVERTS AT LEACHING FACILITY: PARCEL: 8 4 INVERT AT BEGINNING 7.50 __ ._ - OF LEACHING TRENCH 44.69 G , SEPTIC TP ^' 58.40 X59.6 ZONING DISTRICT B-3 r o OVERLAY DISTRICT. APD fy TANK � 4" INVERT AT END SETBACKS: FRONT 30' OF LEACHING TRENCH 44.50 H RESERVE AREA ' SIDE 10' ELEVATION AT BOTTOM MID) REAR 30' OF LEACHING TRENCH 42.50 J ' (3)38' LONG ,' " " M ' ` MINIMUM LOT SIZE: 40,0001 S.F. TRENCHES EST. HIGH GROUNDWATER BELOW 35.85 K s. _,� - NITROGEN SENSITIVE -LL--_ 4'VENT 1.5% ZONE: ZONE II VENT SYSTEM DETAIL: r7��62IH44PP C OSP LCBEORMS PIPE a �o� 0 M H J J r U X I .. �- - I-' L H I V V I t VV °IS DoE` TH F N OTES: 6 SEE SEPARATE EXISTING CONDITIONS PLANS AND PROPOSED SITE PLANS PREPARED BY THE BSC GROUP FOR ADDITIONAL INFORMATION E AL - SCALE: I' = 20 FEET u11?aeMoc/ 0 10 20. 40 FT. REVISIONS NO. DATE DESCRIPTION GENERAL NOTES: I. THIS PLAN IS FOR DESIGN AND CONSTRUCTION OF THE SEWAGE DISPOSAL FACILITY ONLY. 2. ALL CONSTRUCTION METHODS AND MATERIALS SHALL CONFORM TO MASS. D.E.P TITLE 5 AND LOCAL BOARD OF HEALTH REGULATIONS. 3. ALL PIPES LOCATED UNDER PAVEMENT OR TRAVELED WAY SHALL BE SCHEDULE 40 OR EQUAL 4. THERE ARE NO KNOWN PRIVATE WELLS LOCATED WITHIN 150 FT. OF THE PROPOSED LEACHING FACILITY NOR ANY KNOWN WELLS PROPOSED WITHIN 150' OF ANY KNOWN LEACHING FACILITY. 5. WITHIN LIMIT OF EXCAVATION REMOVE ALL TOPSOIL, SUBSOIL AND OTHER IMPERVIOUS MATERIAL 6. REPLACE WITH CLEAN WASHED SAND OR OTHER CLEAN GRANULAR SOILS CONFORMING TO THE FOLLOWING SIEVE ANALYSIS: 1ox (MAX) BY Wr. SHALL PASS No. 50 SIEVE <10 % OF No. 4 SIEVE SHALL PASS No. 100 <5 X OF No. 4 STEVE SHALL PASS No. 200 UNIFORMITY COEFFICIENT O No. 4 SIEVE </=8.0 7. EXISTING UTIUTIES WHERE SHOWN IN THE DRAWINGS ARE APPROXIMATE. THE CONTRACTOR SHALL BE RESPON- SIBLE FOR PROPERLY LOCATING AND COORDINATING THE PROPOSED CON- STRUCTION ACTIVITY WITH DIG -SAFE AND THE APPLICABLE UTILITY COMPANY AND MAINTAINING THE EXISTING U71UTY SYSTEM IN SERVICE. DIG -SAFE SHALL BE NOTIFIED PER THE STATE OF MASSACHUSETTS STATUTE CHAPTER 82, SECTION 409 AT TEL 1-888-344-7233. THE ENGINEER DOES NOT GUARANTEE THEIR ACCURACY OR THAT ALL UTIUTIES AND SUBSURFACE STRUCTURES ARE SHOWN. LOCATIONS AND ELEVATIONS OF UNDERGROUND UTILITIES TAKEN FROM RECORD PLANS. THE CONTRACTOR SHALL VERIFY SIZE, LOCATION AND INVERTS OF UTILITIES AND STRUCTURES AS REQUIRED PRIOR TO THE START OF CONSTRUCTION. & THIS SYSTEM IS NOT DESIGNED FOR THE USE OF A GARBAGE GRINDER. A GARBAGE GRINDER IS NOT RECOMMENDED DUE TO RECOGNIZED ADVERSE IMPACTS TO THE LEACHING 11 FACILITY. 9. THE ENGINEER IS TO BE NOTIFIED OF ANY FIELD CHANCES THAT MAY BE REQUIRED. 10. THE LOT SHOWN HEREON IS BASED ON A PLAN OF LAND PREPARED BY 'OUTERMOST LAND SURVEY` AND RECORED IN THE BARNSTABLE REGISTRY OF DEEDS IN PLAN BOOK 580, PAGE 82. BSC GROUP 657 Main Street, (RT. 28) Unit 6 W. Yarmouth Massachusetts 02673 508 778 8919 PROJECT TITLE: SEWAGE DISPOSAL SYSTEM DESIGN 203 WILLOW STREET YARMOUTHPORT MASSACHUSETTS APPLICANT. COPS BROOK REALTY TRUST YARMOUTH, MA PREPARED FOR: BROWN, LINDQUIST, FENUCCIO & RABER ARCHITECTS 923 MAIN STREET YARMOUTHPORT, MA 02675 DATE: 5/19/03 COMP. DESIGN: LMACDONALD CHECK: J. DONOVAN DRAWN: LMACDONALD FIELD: D. GAZZOLO/J. MOCARTIN FILE NO. 8377-SEP.DWG DWG NO. 5351-03 JOB NO. 4-8377.00 SHEET 1 OF 1