Loading...
HomeMy WebLinkAbout203 Willow Street - Sewage Disposal SystemSOIL TEST PIT DATA: FEBRUARY 14, 2002 TEST PIT 92- TEST PIT _0 GRD. EL 48.85 GRD. EL 58.02 EST. HIGH GW. NIA EST. HIGH GW. N/A IN 2 MEDIUM SAND 2.5Y 6/3 NO WATER EL = 35.85 5' MEDIUM SAND 2.5Y 6/4 NO WATER FI - 45-0 2" INDICATES PERC. TEST 30" EINDICATES UNSUITABLE MATERIAL 156' SEPTIC TANK DETAIL: NOT TO SCALE NOTES: 1. SEPTIC TANK SHALL BE STEEL REINFORCED CONCRETE. 2. SEPTIC TANK TO WITHSTAND H-20 LOADING. 3. ALL POPE CONNECTIONS AND CONCRETE CONSTRUCTION SHALL BE WATERTIGHT. 4. FILL ALL UNUSED KNOCKOUTS WITH MORTAR. 1,500 GALLON 5. INLET AND OUTLET TEES TO SHALL BE SCHED. 40 PVC. TEES SHALL BE LOCATED UNDER MANHOLE COVER FOR EASE OF SERVICING. S. RECOMMENDED MANUFACTURER-ROTONDO OR APPROVED EQUAL 7. SEPTIC TANK SHALL BE WARRANTED BY MANUFACTURER. 2-18" dA C.I. (60! MIN.) MANHOLE COVERS 11E UNDER BROUGHT TO FNI GR M.H. OPENING 1. S. I' � • I' LL' '0" 6. RAISE M.H W,[.. SEWER BRICK e. •:_ __ :- -! 10-0' &MORTAR i • 12 T .e 3 PRECAST SEPTIC TANK 10 14' a INLET 4'-9' 4 -0 MIN. 6'-2' _ LIQUID DEPTH• N DATE: DATE: COMPACTED CRUSHED STONE 02/14/02 02/14/02 PLAN VIEW _ ��...�..�. DISTRIBUTION BOX DETAIL: NOT TO SCALE GENERAL NOTES: 1. THIS PLAN IS FOR DESIGN AND CONSTRUCTION OF THE SEWAGE DISPOSAL FACILITY ONLY. 2. ALL CONSTRUCTION METHODS AND NO. OF OUTLETS : 9 RAISE M.H W/ 18" DIA C.I.(60/ MIN.) MANHOLE COVER 3. ALL PIPES LOCATED UNDER PAVEMENT SEWER BRICK BROUGHT TO FltrydISH GRADE 4. THERE ARE NO KNOVIN PRIVATE WELLS & MORTAR PROPOSED LEACHING FACILITY NOR ANY KNOWN WELLS PROPOSED WITHIN NOTES: COVER1 REMOVABLEQ'Ax�. 2 WALLS 1. DIST. BOX TO NATHSTAND H-20 LOADING. 6. REPLACE WITH CLEAN WASHED SAND 2' 2. PROVIDE INLET TEE OR BAFFLE WHERE SLOPE OF PIPE EXCEEDS 0.08 FT./FT OR SIEVE ANALYSIS: T 15 PASS No. 50 SIEVE IN PUMPED SYSTEM. PASS No. 100 9I 3. FORST TWO FEET OF PIPE OUT OF DIST. BOX TO BE WD LEVEL a�� .� 4. RECOMMENDED MANUFACTURER-ROTONDO ,p ° L_ 2 OR APPROVED EQUAL COORDINATING THE PROPOSED CON- BOTTOM ON LEVEL STABLE BASE 6' MIN. 3/4' TO S. ALL PIPE CONNECTIONS AND CONCRETE CONSTRUCTION SHALL BE WATERTIGHT. COMPANY AND MAINTAINING THE CROSS-SECTION 1 1/2' CRUSHED STONE BASE 6. RAISE MANHOLES TO FINISH GRADE WITH 7 f SEWER BRICK AND MORTAR. FULL OUTER MORTAR PARGE TO PROVIDE WATER TIGHT SEAL 7. FILL ALL UNUSED KNOCKOUTS WITH MORTI LEACHING TRENCH DETAIL: NOT TO SCALE 36" MAX .COVER 4" VENT PIPE TO Y ON LA ALS FINISHED GRADE SEE DETAIL LOAM & SEED DISTURBED AREAS 4' PVC • •�-a '=4'�F' '�VC�--0.0= .... CAP ENDS bg, `n�• cr mmnc vm LEVEL BOTTOM \ 36' PROFILE 36' MAX. - 12' MIN. COVER .--- 4' MIN. LOAM & SEED L2' MIN. OF IIV TO 1/2" WASHED STONE A 3/4* SHED STONE (NOO nNNE20 E L-WS) CROSS-SECTION T IRON COVERS FINISHED GRADE SEPTIC TANK 9 OUTLET DIST. BOX INVERT ELEVATIONS: TOP OF SLAB 47.50 A 4" INVERT AT BUILDING 45.65 B 4" INVERT AT SEPTIC TANK (IN) 45.25 C 4" INVERT AT SEPTIC TANK (OUT) 45.00 D 4" INVERT AT DIST. BOX (IN) 44.95 E 4" INVERT AT DIST. BOX (OUT) 44.78 F INVERTS AT LEACHING FACILITY: 4" INVERT AT BEGINNING OF LEACHING TRENCH 44.69 G 4" INVERT AT END OF LEACHING TRENCH 44.50 H ELEVATION AT BOTTOM OF LEACHING TRENCH 42.50 J EST. HIGH GROUNDWATER BELOW 35.85 K VENT SYSTEM DETAIL: 0 o 4" PVC HEADER ALL PIPE BELOW GRADE WALAYER 1 DST3/8' 4 PVC HEADER _ ..:., _ LUUUN I "�4' PVC TEE '---,4' PVC RISER D cLISA ��A 4' PVC 90' ELBOW R AILR0 r $ MACDONALD TT MACDVIL II `cS CIVIL "-1 1/2" WASHED CRUSHED STONE �u' 1 S I I CIVIL ASS A 1 1 v a as 4D134 PLAN VIEW 4D134 NOTES: E ALTHSCALE: 1' 20 FEET , 6 ,__.._ --- = �G•��• SEE SEPARATE EXISTING CONDITIONS PLANS AND PROPOSED SITE PLANS PREPARED BY THE BSC GROUP FOR ADDITIONAL INFORMATION 0 LO 20 40 FT. GJ % S/%9/03 REVISIONS NO. DATE DESCRIPTION GENERAL NOTES: 1. THIS PLAN IS FOR DESIGN AND CONSTRUCTION OF THE SEWAGE DISPOSAL FACILITY ONLY. 2. ALL CONSTRUCTION METHODS AND MATERIALS SHALL CONFORM TO MASS. D.E.P TITLE 5 AND LOCAL BOARD OF HEALTH REGULATIONS. 3. ALL PIPES LOCATED UNDER PAVEMENT OR TRAVELED WAY SHALL BE SCHEDULE 40 OR EQUAL 4. THERE ARE NO KNOVIN PRIVATE WELLS LOCATED WITHIN 150 FT. OF THE PROPOSED LEACHING FACILITY NOR ANY KNOWN WELLS PROPOSED WITHIN 150' OF ANY KNOWN LEACHING FACILITY. 5. WITHIN LIMIT OF EXCAVATION REMOVE ALL TOPSOIL, SUBSOIL AND OTHER IMPERVIOUS MATERIAL 6. REPLACE WITH CLEAN WASHED SAND OR OTHER CLEAN GRANULAR SOILS CONFORMING TO THE FOLLOWING SIEVE ANALYSIS: 10% (MAX) BY WT. SHALL PASS No. 50 SIEVE <10 X OF No. 4 SIEVE SHALL PASS No. 100 <5 X OF No. 4 SIEVE SHALL PASS No. 200 UNIFORMITY COEFFICIENT O No. 4 SIEVE </-6.0 7. EXISTING UTILITIES WHERE MOWN IN THE DRAWINGS ARE APPROXIMATE. THE CONTRACTOR SHALL BE RESPON- SIBLE FOR PROPERLY LOCATING AND COORDINATING THE PROPOSED CON- STRUCTION ACTIVITY WITH DIG -SAFE AND THE APPUCABLE UTILITY COMPANY AND MAINTAINING THE EXISTING UTILITY SYSTEM IN SERVICE. DIG -SAFE SHALL BE NOTIFIED PER THE STATE OF MASSACHUSETTS STATUTE CHAPTER 82, SECTION 409 AT TEL 1-888-344-7233. THE ENGINEER DOES NOT GUARANTEE THEIR ACCURACY OR THAT ALL UTILITIES AND SUBSURFACE STRUCTURES ARE SHOWN. LOCATIONS AND ELEVATIONS OF UNDERGROUND UTILITIES TAKEN FROM RECORD PLANS. THE CONTRACTOR SHALL VERIFY SIZE, LOCATION AND INVERTS OF UTILITIES AND STRUCTURES AS REQUIRED PRIOR TO THE START OF CONSTRUCTION. 8. THIS SYSTEM IS NOT DESIGNED FOR THE USE OF A GARBAGE GRINDER. A GARBAGE GRINDER IS NOT RECOMMENDED DUE TO RECOGNIZED ADVERSE IMPACTS TO THE LEACHING FACILITY. 9. THE ENGINEER IS TO BE NOTIFIED OF ANY FIELD CHANGES THAT MAY BE REQUIRED. 10. THE LOT MOWN HEREON IS BASED ON A PLAN OF LAND PREPARED BY 'OUTERMOST LAND SURVEY" AND RECORED IN THE BARNSTABLE REGISTRY OF DEEDS IN PLAN BOOK 580, PACE 82- 2BSC BSCGROUP 657 Main Street, (RT. 28) Unit 6 W. Yarmouth Massachusetts 02673 508 778 8919 PROJECT TITLE: SEWAGE DISPOSAL SYSTEM DESIGN #203 WILLOW STREET YARMOUTHPORT MASSACHUSETTS APPLICANT- COY'S BROOK REALTY TRUST YARMOUTH, MA PREPARED FOR: BROWN, LINDQUIST, FENUCCIO & RABER ARCHITECTS 923 MAIN STREET YARMOUTHPORT, MA 02675 DATE: 5/19/03 COMP./DESIGN: LMACDONALD CHECK: J. DONOVAN DRAWN: LMACDONALD FIELD: D. GAZZOLO/J. MaCARTIN FILE NO. 8377-SEP.DWG DWG NO. 5351-03 SHEET 1 OF 1 JOB N0.4-8377.00