HomeMy WebLinkAbout0 Willow Street - Cape Light Compact - Site Plan 10'TALI -ATI ON EM PUMPS SHALL BE MYERS SRM 4/10 HP PUMPS OR EQUAL L BE INSTALLED IN STRICT CONFORMANCE WITH THE MANUFACTURERS NS. PRIOR TO ORDERING PUMPING EQUIPMENT AND THE INSTALLER IDE THE DESIGN SHOP DRAWINGS OF THE ALL PUMPING EQUIPMENT FOR NSTALLER SHALL CONFIRM THAT THE REQUIRED POWER CONFIGURATION FOR IAP 5 IS AVAILABLE AT THE SITE. NOTE STAINLESS STEEL RAIL MOUNT REQ. PUMP CONTROLS SHALL BE LOCATED WITHIN THE OFFICE IN AN AREA AND SHALL BE ENCLOSED AS REQUIRED TO MEET ALL STATE AND S AND REGULATIONS. THE PUMPS SHALL OPERATE ALTERNATELY WITH lTION APPLYING THE REQUIRED DOSE TO THE LEACHING FIELD. _L BE PROVIDED WITH A LOW LEVEL OVERRIDE AND REDUNDANT ALARM SET SUCH THAT THE PUMPS REMAIN SUBMERGED. .L OPERATE FOLLOWING SEQUENCE: OFF5' S' 5' .2.5' lump ON f�-if----I Ib'=�. jI I-i6__'jl ON AND LAG PUMP ON (TWO PUMPS OPERATE OR ALTERNATE PUMP MUTES FOR FAILED PUMP) MUST ALTERNATE I �4"PERF. SCH40 PVC LINES 30' LIMPS SHALL BE EQUIPPED WITH AN ALARM POWERED BY A CIRCUIT 'ROM THE PUMP POWER. THE ALARM SHALL CONSIST OF A RED LEACHING BED SECTION SHOWING LATERAL SPACING 'HT AND LL SIGNAL ADIBLE SIGNAL WTH OW WATER CONDITION SS TO (PUMPSLNOTESWITCH. THE SCALE. 1"=10 SUBMERGED) AND A I LEVEL CAUSED BY PUMP FAILURE. JCTION OF PUMPS. CONTROLS AND ALARMS SHALL BE DEMONSTRATED BY ER TESTING, ENGINEER TO WITNESS AND CERTIFY ALARM AND CONTROL PANEL TO BE INSTALLED INSIDE _ - BUILDINGS. ALARM TO BE ON SEPARATE CIRCUIT FROM PUMP < BUILDING ELECTRIC PERMIT REQUIRED M A) (BLDG 9) AGE OFFICE A B) (BLDG 8) t 24"I.D.MANHOLE SEE DETAIL 2'-10" MANUF. LeBARON, BROCKTON, MA MODEL, LT 105 WEIGHT: 430 LBS TYPICAL ACCESS COVER SCALE: 3/4" = 1'-0" 32" 24" EL 36.7 B TYP• EL. 36.5 B r 35.0 A 34.5 B 10" 14" a 34.7 A TEE TEE 34.39 A- 14- 34.2 B 1500 GAL H-20 34.45 A 33.89 8 SEPTIC TANK GAS & 4" SCH-4D PVC AT 29 4' LIQ, LEVEL Z�EL FILTER •' 33.95 B .'. ACME OR EQUAL A100 4' SCH-40 PVC AT 2% 6" GRAVEL & MECH. 3' AT 0.02 COMPACTION (TYP.) SEPTIC TANK 1500 GAL -20 SEPTIC TANK DEPTH OF FLOW = 4' 4' LIQ= LEVEL FOUNDATION TEE SIZES: ACME OR EQUAL INLET DEPTH = 10" OUTLET DEPTH = 14" TA I\IVc RI nC,q PROPOSED SLAB FOUNDATION LRSLELOOR EL BUILDING NO. 10 FOUNDATION PROPOSED SLAB FOUNDATION --- FIRST FLOOR EL VARIES SEE PLAI BLDG 1 38.5 SYSTEM C BLDG 2 39.5 SYSTEM D 4" SCH-40'PVC AT 2WIN. TE: SEE ABOVE T-&--P-Ik=SfOR- ILDING NO. 8 OPOSED INVERTS F1 11 Rt " EL. 14.18 BLDG B 1 PVC AT 2%M)N. 32' BLDG B THi -U OIL EVALUATOR: DAN OJALA P.L.S., SE OIL EVALUATOR: DAN OJALA P.L.S., SE SOIL EVALUATOR: DAN OJALA P.L.S. DOWN CAPE ENGINEERING DOWN CAPE ENGINEERING DOWN CAPE ENGINEERING DOWN CAPE ENGINEERING WELCH (BOH) oo EXCV. STEVE VAUGHN(BORTOLOTTI) EXCV. STEVE VAUGHN(BORTOLOTTI) WITNESS: KELDA EXCV. SCOTT (BORTOLQTTI) EXCV. SCOTT (BORTOLOTTI) DATE: 7-2-99 2 PM 0-2' 0 ORGANIC 10YR2/1 DATE: 7-2-99 2 PM 0-2- 0 ORGANIC 10YR2/1 DATE: MAY 22 1999 DATE: MAY 22 1999 0-3" 0 ORGANIC t0YR3/2 440 GAL RESERVE 2-4" A LOAMY SAND 10YR3/2 0-2" 0 ORGANIC 10YR3/2 2-5" A LOAMY SAND 10YR�4 ? P70' A TO SECOND TYP. 270' B PUMP CHAMBER FRAME AND GRATE 5-3B" B LOAMY SAND 10YR6 6 3' HI ALARM ON 60"-84' C2 LOAMY SAND 2. 8/4 REMOVE C2 FOR DRAINAGE, - CHECK ALVE MAINTAIN FROST 38-66" C1 M/C SAND 2.5Y6/6 30-48" C1 M/C SAND 2.5Y6/6 10% GRAVEL pump ON 4 78"-138" C3 M/C SAND 2.5Y7/6 NO WEEP HOLE PROTECTION (4') 48-68" C2 MEED SAND 2.6Y7/3 PUMP OFF 78-144"C3 M/C SAND t0YR5/6 68-168"C3 M/C SAND 2.5Y6/6 LENS OF SILT LOAM FROM 5'-10' SCALE: 3/4" NO GROUNDWATER FOUND 2 LOW ALARM GROUNDWATER FOUND AT 12.0' ON SOUTH SIDE OF HOLE FLOAT SWITCH 4" WORKING RANGE MINIMUM WEIGHT: 388 LBS. 1' EL. 37.7 0" SETTINGS: SET AS SHOWN EL 37.1 0" EL. 37.7 0 0" 0 2" 6' GRAVEL &•MECH. \ 3 A 4' COMPACTION (7YP.) A 5" A 8" 8 B DUAL MYERS SRM4 Yo HP PUMPS B ZONE E EL 34.7 36" PUMP CHAMBER MOUNT ON MYERS CHAIN PULL STAINLESS EL. 35.2 30' AIW247 4/99 23.9 -ZONE D-5.3 C1 C11 STEEL RAIL MOUNT SYSTEM (NO SUBSTITUTIONS) AIW230 4/99 23.5 ZONE E-4.5 60" 1000 GAL H-20 C1 USE 5.3' ADJ. EL 32.7 EL. 3212 66" PUVP CHAMBER EL 33J5 48' CI C2 84" 4' U0. LEVEL C2 BOTTOM PERC AT 46" 84" EL. 29.70 ACME OR EQUAL 24 GAL POURED EL 32.08 68 6"AT 10:30 <2 MIN/IN EL 30.70 EL 31.64 _ ADJ. WATER 24 GAL POURED IN 4:30 ALARM AND CONTROL PANEL C2 <2 MIN/IN THi THI SOIL EVALUATOR: DAN OJALA P.L.S. OIL EVALUATOR: DAN OJALA P.L.S., SE OIL EVALUATOR: DAN OJALA P.L.S., SE SOIL EVALUATOR: DAN OJALA P.L.S. DOWN CAPE ENGINEERING DOWN CAPE ENGINEERING DOWN CAPE ENGINEERING DOWN CAPE ENGINEERING WELCH (BOH) WITNESS: KELDA WELCH (BOH) EXCV. STEVE VAUGHN(BORTOLOTTI) EXCV. STEVE VAUGHN(BORTOLOTTI) WITNESS: KELDA EXCV. SCOTT (BORTOLQTTI) EXCV. SCOTT (BORTOLOTTI) DATE: 7-2-99 2 PM 0-2' 0 ORGANIC 10YR2/1 DATE: 7-2-99 2 PM 0-2- 0 ORGANIC 10YR2/1 DATE: MAY 22 1999 DATE: MAY 22 1999 0-3" 0 ORGANIC t0YR3/2 2-4" A LOAMY SAND 10YR5/2 2-4" A LOAMY SAND 10YR3/2 0-2" 0 ORGANIC 10YR3/2 2-5" A LOAMY SAND 10YR�4 3-8' A LOAMY SAND t0YR/4 363600 C10AMY SAND M/F SAND 22: Y/'7/4 (LOWER 12" 10YR3/2) 3636V C10AMY SAND M/F SAND 22: 17/4 5-3B" B LOAMY SAND 10YR6 6 8-30" B LOAMY SAND 10YR5 8 60"-84' C2 LOAMY SAND 2. 8/4 REMOVE C2 FOR DRAINAGE, 66"-78" C2 SILT LOAM 2.5Y6/4 (UNSUITABLE, REMOVE) 38-66" C1 M/C SAND 2.5Y6/6 30-48" C1 M/C SAND 2.5Y6/6 10% GRAVEL 84"-132" C3 M/C SAND 2.5Y7/6 OK FOR SAS) 78"-138" C3 M/C SAND 2.5Y7/6 66-78" C2 SANDY LOAM 7.5YR6/6 (FIRM, UNSUITABLE) 48-68" C2 MEED SAND 2.6Y7/3 78-144"C3 M/C SAND t0YR5/6 68-168"C3 M/C SAND 2.5Y6/6 LENS OF SILT LOAM FROM 5'-10' NO GROUNDWATER FOUND NO GROUNDWATER FOUND GROUNDWATER FOUND AT 10.8' GROUNDWATER FOUND AT 12.0' ON SOUTH SIDE OF HOLE UNSUITABLE; REMOVE EL. 37.7 0" EL. 36.7 0" EL 37.1 0" EL. 37.7 0 0" 0 2" 0 A 2" 0 2' 3 A 4' 4' A 5" A 8" 8 B B ZONE E B ZONE E EL 34.7 36" EL. 33.7 38' AIW247 4/99 23.9 -ZONE D-5.3 EL. 35.2 30' AIW247 4/99 23.9 -ZONE D-5.3 C1 C11 £L 33.9 38" AIW230 4/99 23.5 ZONE E-4.5 AIW230 4/99 23.5 ZONE E-4.5 60" USE 5.3' ADJ. C1 USE 5.3' ADJ. EL 32.7 EL. 3212 66" EL 33J5 48' CI C2 84" C1 C2 BOTTOM PERC AT 46" 84" EL. 29.70 BOTTOM PERC AT 81' 24 GAL POURED EL 32.08 68 6"AT 10:30 <2 MIN/IN EL 30.70 EL 31.64 _ ADJ. WATER 24 GAL POURED IN 4:30 EL 31.05 _ ADJ. WATER C2 <2 MIN/IN C3 C3 EL 30.64 78" 5.3� 5.3'C3 C3 EL 26.34 _ OBSV. WATER AT 10.8' EL. 25.75 _ OBSV. WATER AT 12.0' EL 28.7 132". EL. 25.2 138' EL 25.14 144" EL. 23.75 168" THS TH7 SOIL EVALUATOR: DAN OJALA P.LS., SE TH8 SOIL EVALUATOR: DAN OJALA P.L.S., SE SOIL EVALUATOR: DAN OJALA P.L.S.. SE DOWN CAPE ENGINEERING DOWN CAPE ENGINEERING SOWN CAPE E NGINEERING NGINEE(BORTOLOTTI) TH6 (AUGER HOLE) P.L.S. EXCV. STEVE VAUGHN(BORTOLOTT) EXCV. STEVE VAUGHN(BORTOLOTTI) EXCV. STEVE SOIL EVALUATOR: BAN OJALA DATE: 7-2-99 2 PM DATE: 7-2-99 2 PM ATE: 7-2-99 2 PM DATE: SOWN CAPE ENGINEERING CAPE E 0-3" 0/A LOAMY SAND 10YR3/2 0-2" O/A LOAMY SAND 10YR4/2 0 ORGANIC 10YR2/1 DATE: 9 2 PM 3-5" E LOAMY SAND 10YR7/2 2-4" E LOAMY SAND 1OYR6/1 2-4" A LOAMY SAND 10YR5/2 5-34" B LOAMY SAND 10Y7/8 4-36" 8 LOAMY SAND IOYRS/6 VARIGATED COLORS AT 84' 4-36" B LOAMY SAND 2.5Y7/6 (TRACE SILT) 0-1" 0 ORGANIC 10YR2/1 34-132" C1 MED SAND 2. Y7/4 36-132" C1 M/C SAND 2.5Y7/6 36-66" C1 M/F SAND 2.5Y6/4 66"-72" C2 SILT LOAM 2.5Y7/4 (UNSUITABLE, REMOVE) 1-3" A LOAMY SAND t0YR3 2 3-36" B LOAMY SAND 10YR6/8 toy GRAVEL GROUNDWATER AT 10.5' GROUNDWATER AT 10.6' 72"-138" C3 M/C SAND 2.SY6/4 36-126" CI M/C SAND 2.5Y7/6 10% GRAVEL NO GROUNDWATER FOUND O" EL. 36.9 0 i" EL. 35.44 0" EL. 36.20 0" 0/A EL 38.0 0 0" A 0/A 3" 2" 2" 3" EE 4" A 4" ZONE E5" B ' AIW247 4/99 23'9 -ZONE 0-5.3 B ZONE E B ZONE E B EL 33.9 36 AIW230 4/99 23.5 ZONE E-4.5 AIW247 6/99 24.3 -ZONE D-6.0 EL 33.20 36" AIW247 6/99 24.3 -ZONE D-6.0 EL. 35.0 36" USE 5.3' ADJ. EL 32.60 34" AIW230 6/99 23.9 ZONE E-5.1 A1W230 6/99 23.9 ZONE E-5.1 USE 6.0' ADJ. USE 8.0' ADJ. C1 O1 EL 32.5 66" C1 C1 C2 72" EL. 31.8 _ ADJ. WATER BOTTOM PERC AT 78" EL 32.0 8: 24 GAL IN 8:30 EL. 30.94 _ ADJ. WATER <2 MIN/IN EL. 31.60 _ ADJ. WATER 5.3' 6.0' C36.0' EL. 25.5 _ OBSV. WATER AT im0?INECT ENDS WITH 4"SCH SOLID EL. 26.4 126" PIPE AND VENT AS SHOWN. � 24=94 _ 126" - EL. 25.60 _ 127" 23.55 132" EL. 25.20 132" (, TO BE INSTALLED INSIDE 24 H-20 CAST IRON COVER EL 26.5 138" BUILDING. ALARM TO E ON SEPARATE CIRCUIT FROM PUMP INLET TEE ELECTRIC PERMIT REQUIRED - - 2000 CAL H-20 TEE TEE 4' LIQ. LEVEL W BAFFU star nP cnuA"-__iABEL�IL7 6" GRAVEL & MECH. S-EPTI_� t«TANK- DEPTH OF FLOW - 4' INLET. DEPTH - 10" Al ITI IT nF u = TYP. 35.15 fpµ` " cc�l-40 Pu 6' AT 0.02 29" TEE / 29' W/ C. 4500 GAL 2400 1000 GAL R_SERVE --A-ALARM-ON-- , -A-ALARupNr PUMP ON -PUMP OFF LOW ALARM 1' UP BLOCK UP D -80X, 24 I.D. RISER WWI 140 EL 39.5E 38.76 MIN. OR EQUAL ;>fPES FOR I1RST TWO FEET i TO D -BOX ° WEEP HOLE TYP. �r 4"4SCH40 PVC 0 o0 o D O o 0 o C o °ooc°o0° 0°0°00°000 0000000°0°°°0°0°°' CHECK VALVE TYP.6 S-1 ° �oyo-0�0�0�0 0 o�oa-ovoe 000po°o°000°o°00000°o°°Oo°000°aoo 0 0 0 0 0 0 0 0 14'VAX. ('VARIES) 4"OSCH-40 PVC LINES AT 0.5X., TITLE 5 ORIFICES. B URA ACME DB9 H-20 OR EQUAL INV.'S 37.51 37.01 SF lEA9HING Firl!) S'S =IRKING RANGF SET AS SHOWN �" TO 1-4" DOUBLE WASHED STONE 6" BELOW INVERT )UAL MYERS SRM4 & HP PUMPS MOUNT ON MYERS CHAIN PULL STAINLESS STEEL RAIL MOUNT SYSTEM (NO SUBSTITU PUMP CHAMBER 4' Ito 1 NSI ACME OR EQUAL ENLLEE NEL TO ISTTADINSID BUILDING. ALARM TO BE ON SEPARATE CIRCUIT FROM PUMP ELECTRIC PERMIT REQUIRED 34.A/,OL33" 2000 GAL RESERVE IN TEEALARM ON 'ORAGEMP OFF 24"H-20 CAST IRON COVER INLET TEE BLOCK UP D -BOX, 241.D. RISER MPONEHT�-(T 39.0 MIN. B t I FOR FIRST TWO FEET 4"OSCH40 PV '0°0°o�o 36.0 000000000000000 _3Z-8 S=1S C +:°a°.°o 0 0 00o0oO-Qoao ° pQ DOoo0 0�o�0000 °00000o`!o°a°o°a^a BOX t 14- ACME D89 H-20 OF EQUAL INV. 37.75 37.25 ECK VALVE TYP. 14'MAX. (VARIES) 4"OSCH40 PVr _ 7000 GAL ST MECHANICAL CAL COMPACTION & 6' STONE (TYP.) 310 CMR 15.228(1) 10'X17' ACME LOW PROFILE OR EQUAL 3000 GAL PUMP CHAMBER 7'X17' ACME LOW PROFILE OR EQUAL DEPTH OF FLOW . 6--7- TEE SIZES: INLET DEPTH = 10" OUTLET DEPTH =. 29" FABRIC OVER DRILL (2) 1-0 OVERLAP 12" HOLES " PEASTONE OVER PIPE 12"0 SLOTTED H-20 MORTAR ALL COMPONENTS CORRUGATED HDPE PIPE (TYP.) ' ADS N-12 OR EQUAL 75"-1.5" DOUBLE D WASHED STONE 2' t EL 32.8 TTP. �4 p' ALL UNSUITABLE MATERIALS TO BE REMOVED I ,1• FOR 5' HORIZONTALLY AND TO REQUIRED DEPTH AROUND ALL LEACHING TRENCH. ENGINEER TO INSPECT. UNSUITABLE SUBSOIL AVERAGED 3' DEPTH. TRENCH CROSS SECTION NTS BOTTOM LEVEL AT EL. 32 ADJ. G.W. EL. 30.9' ON SOUTH END OF SITE J. BLOC TOP OF SCALE: N.T.S. _ - 12.0' (TYP-) 0 0 0 ei o;. 3' C.B. TRAP 0.. 172"0 ELBOW IPE SLOTTED H-20 PROPOSED 1000 GALLON PRECAST 12"� HDPE H-20 CATCH BASIN LEVEL BETWEEN BASINS OX6'-S" SHOREY SOLID BASIN H-20 OR EQUAL SECTIONAL PLATE ;OSS SECTION 11V. I .. v..`.. FIELD SAS n 140 N -WOVEi4-M EQUAL OVER PIPE AND VENT IN ISLAND AS 2" noNAIF WASH PFAcrnuc nyca 4"SCHAO PIPF�' 4"6SCH-40 PVC LINES AT 0.5X• TITLE 5 ORIFICES. 3/ f TO 1-4" DOUBLE WASHED STONE 6" BELOW INVERT LEACHING FIELD SAS I M 310 CUR 15255'CONSMUC110N IN FILL' REMOVE TO 114E B7ROY OF INE 8 LAYER AND ANY uRWARE SOIL AS SHOWN INSECT SCREEN 12' X 3"I-- -1' TOPCOAT MASS DPW CCBERM / TYPE 11 1Z FKUctSSLU liKAVtL MDPW M1.03.1 NB. ROLLER COMPACTED REMOVE TOP &SUBSOIL COMPACT SUBBASE T CROSS SECTION NOT TO SCALE qi DETAIL SHEET ACCOMPANYING SITE PLAN OF LAND IN WEST YARMOUTH, MA CAPE LIGHT COMMONS OFFICE PARK AND STORAGE CENTER SCALE AS NOTED DATE: 7-19-99 REVISED: 2-13-01 PREPARED FOR: BORNSTEIN COMPANIES 297 NORTH STREET off 508-352-4541 HYANNIS, MA fax 608 382-9880 down cape engineering, inc. CIVIL ENGINEERS LAND SURVEYORS 939 main st. garmouthport, ma 02675 SHEET 2 OF 2