Loading...
HomeMy WebLinkAboutEngineered Plans - 2016r BENCHMARK COR./BULKHEAD EL. =103.88 99.36 x 100,13 4 J 98, 5 �y.:,.'99J5> :.. \ 98.07 99 9,90610_ xi � S 89 54 1 E T` O" 10216 85.00' EXISTING SEPTIC TANK (TO REMAIN) INV. (OUT), EL.=101.0±(VERIFY) 99,84 INSTALL A 40 MIL POLY LINER TOP OF LINER, EL.=101.0 BOTTOM OF LINER, EL.=97.0 / I �..,:.,• 101, 1 LOT 9 �:... 8,5000S.F. 01'30++`- I/- 10439 �P// ID: 867-2 10 0 I 103. 103.13 Lg e x e � i� 5 _00 - DUPLEX(J253) T. 0. F. =104.57± 103.88 104:1 LEGEND x 100.98 EXISTING SPOT GRADE _ — 98 — — EXISTING CONTOUR _0. H. W--- OVERHEAD WIRES G EXISTING GAS SERVICE W EXISTING WATER SERVICE TEST PIT BENCHMARK z" -"�A'ql" Pertiit valid for REPAIR OF SEPTIC SYS"1'F;M ONLY, due to State and Local septic variances. Board of F9'ealth review and approval is required for any future additionsllrcnuvations/altera.tions to sewage facilities anti/or structures/dweihng: Yarmouth Ffealth lh-hartment A� PRQVEI /-'Ce TP— � Q!I104IPN O % me U'/ PROPOSED 1000 GALLON SEPTIC TANK IN SERIES 11'--► O O 0 22 O ;_O•...rO. O: J / 10 .$5 t: / x C 1E;1 2,10.'::.: 'PROPOSED S.A.S.: \ - 50. x 04 Ofi�_�160-- ,2 — x 91,E6—_—p_ ___ GS EXISTING LEACH PIT TO BE PUMPED, FILLED WITH SAND & ABANDONED Date VA/ —VW OWNER OF RECORD LIADES, JAMES A 84 ROCKY RIDGE ROAD DENNIS, MA 02638 GENERAL NOTES: ROUTE 6 N Old Townhouse Road CD U) Ivanhoe Rd Q LOCUS -�LA a a ° Ave ,n H -±Once 0 � S Cons _n o v oQ o Cardinal Ln 0 a 3 3 gyp. Bunting Ln 3 0 Dove Ln LOCUS MAP NOT TO SCALE 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2• ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE LOCAL RULES AND REGULATIONS, EXCEPT AS REQUESTED BELOW: —310 CMR 15.405(1)(b): 1) An 8' variance, S.A.S. to cellar wall (bulkhead), for a 12' setback. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. s4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON AN ASSUMED DATUM. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE 8. THERE ARE NO ABUTTING WELLS WITHIN 150' OF THE PROPOSED S.A.S. 9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE DIRECTED BY THE APPROVING AUTHORITIES. 10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION. 11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS IN THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S. AND REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3). 12. AREAS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE INSPECTED BY HEALTH DEPARTMENT PRIOR TO BACKFILL. 13. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY. 14. THE ENGINEER IS NOT RESPONSIBLE FOR ANY UNDOCUMENTED SEPTIC SYSTEM COMPONENTS NOT SHOWN ON THE PLAN. PROPOSED SEPTIC SYSTEM UPGRADE PLAN 253 OLD TOWNHOUSE ROAD, YARMOUTH, MA Prepared for: Capewide Enterprises, 153 Commercial St, Mashpee, MA 02649 Engineering by: SCALE DRAWN JOB. NO. Engineering Works, Inc. 1 "=20' P.T.M. 146-16 12 West Crossfield Road, Forestdale, MA 02644 DATE CHECKED SHEET N0. (508) 477-5313 5/2/16 P.T.M. 1 Of 2 NOTE: TO PREVENT BREAKOUT, THE CONTRACTOR SHALL INSTALL A 40 MIL POLY LINER TOP OF LINER, EL.=101.0 BOTTOM OF LINER, EL.=97.0 SEPTIC TANKS PROPOSED D -BOX PROPOSED S.A.S. INSTALL RISERS & COVERS OVER INLET & INSTALL RISER AND COVER INSTALL RISER & COVER OVER ONE CHAMBER(MIN.) EXISTING OUTLET AND SET TO 6" OF FINISH GRADE SET TO WITHIN 6" OF FINISH AND SET TO WITHIN 3" OF FINISH GRADE TO SERVE DUPLEX(#253) GRADE AS AN INSPECTION MANHOLE. T. 0. F.=104.57f F.G. EL.=103.61 F.G. EL.=104.0± F.G. EL.=103.51 F.G. EL.=103.0± i L = 4' L = 15' L = 28'(MAX) ®"SCH4000 (PVC). ®'SCH40(PVC) �4"SCH40(PVCMIN.) n.�1'�+ 4Q 6" 2" LAYER OF 1/8" '%�/� A N N 14�� INV.- 10 I 14" 12" 100.85 48" LIQUID INV.=100.28 LEVEL jDf TO 1/2 DOUBLE WASH/ED STONE O ®L*4' PROVED FILTER FABRIC) 4' 3'3/4"-1 M`>v �6. 6 n? � ���� _1 ADD GAS BAFFLE 1/2" r-PROPOSED S.A.S. GAS BAFFLE INV.=100.45 -100.00 EFFECTIVE WIDTH 11 DOUBLE WASHED �� ,.. INV. EXISTING H-10 RATED - STONE SEPTIC PROPOSED SEPTIC TANK INV.= 100.60 �$E 7 LC -6 LEACHING CHAMBERS IN SERIES r 50' - TANK H-10 WITH 4' OF DOUBLE WASHED STONE -ALL SIDES INV.=101.0± (EXISTING) H-10 RATED NOTES: TOP CONC. ELEV.=100.8 - - - - -BREAKOUT S.A.S. LAYOUT 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE INV. ELEV.=100.00 ®®®0®®® ELEV.=100.5 INVERTS, PRIOR TO INSTALLATION. E3 E3 E3 E3 E31 E3 E3 zim 2) SEPTIC TANK & D -BOX SHALL BE SET LEVEL AND BOTTOM ELEV.=99.00 TRUE TO GRADE ON A MECHANICALLY COMPACTED 4' 7 x 6' = 42' 4' SIX INCH CRUSHED STONE BASE, AS SPECIFIED IN 4' OF NATURALLY OCCURRING- 310 CMR 4KNOCKOUT - - " 1 15.221(2). PERVIOUS MATERIAL EFFECTIVE LENGTH = 50' 3) INSTALL INLET & OUTLET TEES AS REQUIRED. 5 (MIN.) ABOVE G.W. zo• o� cov> 4) GAS BAFFLE TO BE INSTALLED ON OUTLET TEE OR EQUAL. NO G.W./BOTTOM OF TP„ EL=93.0 LEACHING SYSTEM SECTION CM AS MANUFACTURED BY TUF-TITE, ZABEL 14" KNOCKOUT 4" KNOCKOUTI SEPTIC SYSTEM PROFILE ;_ 4• KNOCKOUT _ _ J _ _ - - - - N.T.S. I , 72" PLAN VIEW DESIGN CRITERIA SOIL LOG _ _- _ NUMBER OF BEDROOMS: 4 BEDROOMS DATE: APRIL 27, 2016 ® ® ® 0 ® ® ® 22" ® 0 SOIL TEXTURAL CLASS: CLASS I MIN/IN SOIL EVALUATOR: PETER'McENTEE PE(SE#1542) WITNESS: AMY VON HONE R.S. HEALTH AGENT IN12RT I ®®®®®®® I I I DESIGN PERCOLATION RATE: <2 DAILY FLOW: 440 GPD ELEV. TP DEPTH � i- - I DESIGN FLOW: 440 GPD 011I' 104.5 A 72" 3s" LOAMY SAND SIDE VIEW END VIEW GARBAGE GRINDER: NO -AND NOT PERMITTED WITH THIS DESIGN 10YR 3/3 103.5 12" EXISTING SEPTIC TANK: 1000 GALLON CAPACITY B WIGGIN LC -6, H-10 LOADING PROPOSED SEPTIC TANK: 1000 GALLON CAPACITY LOAMY SAND 10YR 5/4 LEACHING CHAMBER 101.5 36" LEACHING AREA REQUIRED: (440 GPD) = 594.6 SF G FERC N.T.S. .74 GPD/SFMED. PROPOSED SEPTIC SYSTEM UPGRADE PLAN SAND USE 7 LC -6 LEACHING CHAMBERS IN SERIES 2.5Y 6/4 253 QLD TOWNHOUSE ROAD, YARMOUTH, MA WITH 4' OF DOUBLE WASHED STONE -ALL SIDES Prepared for: Capewide Enterprises, 153 Commercial St, Mashpee, MA 02649 SIDEWALL AREA: (11.0' + 50.0') x 2 x 1' = 122.0 SF Engineering by: SCALE DRAWN JOB. NO. BOTTOM AREA: 11.0' x 50.0' = 550.0 SF TOTAL AREA:.... 672.0 SF s. Engineering Works, Inc. N.T.S. P.T.M. 146-16 ....................................................... „138 PERC RATE <2 MIN IN., C" HORIZON 12 West Crossfield Road, Forestdole, MA 02644 DATE CHECKED SHEET NO. DESIGN FLOW PROVIDED: 0.74 GPD/SF(672.0 SF) = 497.3 GPD NO GROUNDWATER ENCOUNTERED (508) 477-5313 5/2/16 P.T.M. 2 Of 2