Loading...
HomeMy WebLinkAboutEngineered Plan - 2015ACCESS COVERS MUST BE WITHIN INSPECTION 9 " MINIMUM, 6" OF FINISH GRADE PORT 3' MAXIMUM COVER FIRST 2' TO �BE LEVEL CLEAN SAND BACKFILL 99.5 98.5 II- H-20 AROUND AND 2" OVER CHAMBERS BAFFLE 98.67 5,X 1, 98.42 97.5 6 OUTLET 16 HIGH CAPACITY INFILTRATOR EXISTING D -BOX CHAMBERS IN BED FORMATION 1500 GAL H-20 SFPTIr TANK ,..,.,.r INVERT EL E VA T I DNS : INVERT OUT SEPTIC TANK: 99.5 INVERT IN DIST. BOX: 98.67 INVERT OUT DIST. BOX: 98.5 INVERT IN LEACH CHAMBER: 98.42 BOTTOM OF LEACH CHAMBER: 97.5 ADJUSTED GROUND WATER : N/A OBSERVED GROUND WATER: N/A BOTTOM OF TEST HOLE */: 90.t ------- - --- LOCUS MAP 0 r 20 40 40 PROPOSED CONTOUR DESIGN CRITERIA DESIGN FLOW: 3 BEDROOMS AT 1/0 G.P.D. PER BEDROOM EQUALS 330 G.P.D. NO GARBAGE GRINDER SEPTIC TANK REQUIRED: 330 G.P.O. X 200% - 660 GAL. SEPTIC TANK PROVIDED: 1500 GAL. EXISTING SOIL ABSORPTION SYSTEM REQUIRED: DESIGN PERC RATE ( 5 M I N/ I NCH SOIL TEXTURAL CLASS - I EFFL UENT L OA I NG RA TE - 0.74 GPD/SF 330 GPD / 0.74 GPD/SF - 446 S.F. REQUIRED PROVIDED: 16 HIGH CAPACITY INFILTRATOR CHAMBERS. 100'x 4. 73SF/FT - 473 S.F. 473 S.F. x 0.74 - 350 GPD SOIL TEST PIT DA TA bm I NO I CA TES INDICATES PERCOLATION = OBSERVED TEST = GROUNDWATER TP 0/ 0. HORIZON TEXTURE COLOR /01.8 A LOAMY IOYR SAND 3/2 9' -------------------- l0/.0 B LOAMY IOYR SAND 4/6 24" -------------------- 99.8 C / MED I UM IOYR SAND 6/6 44 - 140. NO WATER 90.1 GENERA L NOTES : I. THIS PLAN IS FOR THE DESIGN AND CONSTRUCTION OF THE SEWAGE DISPOSAL SYSTEM ONLY. 2. VERTICAL DATUM IS ASSUMED. FOR BENCH MARKS SET. SEES/ TE PLAN. J. ALL CONSTRUCTION METHODS AND MA TER I AL S AND MAINTENANCE OF THE SEPTIC SYSTEM SHALL CONFORM TO MASS. D.E.P. TITLE 5 AND LOCAL BOARD OF HEALTH REGULATIONS. 4. ALL SEPTIC SYSTEM COMPONENTS LOCATED UNDER AREAS SUBJECT TO VEHICULAR TRAFFIC OR GREATER THAN J' IN DEPTH SHALL BE CAPABLE OF WI TH- STANDING H-20 WHEEL LOADS. 5. ALL SEWER PIPE SHALL BE SCHEDULE 40 PVC OR APPROVED EQUAL. 6. SEPTIC TANK AND D -BOX SHALL BE REINFORCED PRECAST CONCRETE OR APPROVED POLYETHYLENE. BOTH SHALL BE WATERTIGHT. D -BOX SHALL BE WATER TESTED FOR LEVEL WHEN THERE IS MORE THAN ONE OUTLET. 7. BEFORE CONSTRUCTION CALL "DIG -SAFE'. 1 -888 -DIG -SAFE AND THE LOCAL WATER DEPT. FOR LOCATION OF UNDERGROUND UTILITIES. 8. EXISTING LEACH PIT TO BE PUMPED DRY AND BACKFILLED. 9. EXISTING SEPTIC TANK TO BE PUMPED AND CLEANED. INSPECT AND REPLACE INLET TEE IF REQUIRED. VERIFY INVERT ELEVATION PRIOR TO CONSTRUCTION. DATE: DECEMBER 9. 2015 TEST BY: STEPHEN HAAS WITNESSED BY: PHIL RENAUD PERC RATE: C 2 MIN/INCH 10F MASv.s TERRY a yGs� Yarmouth Health Department � " WAR ERNo. 38721 P? VED r Z_-22r % > Name Date SEP T I C S YS TEM CIES l ON 40 SW I I= T BROOK ROAD. MAP 07. PARCEL 230 SOUTH YARMOUTH . MA. PREPARED P'OR ANGEL A RAM/ RE -,Z 3172 NW 32 n d S TREET T. M l AM 1. EL 33142 SCALE: la 20' DECEMBER 23. 2015 STEPHEN A. HAAS _ ENGINEERING, INC R. O. B o x 16 South Dennis, MA 02660 (SOB) 362-8132 JOB NO: 15-065 '