Loading...
HomeMy WebLinkAbout760 Route 28 - Existing Tight TankBMICHLRAFat TOP OF FOUNDATION ELEV. = !P-99__ � (ASSUMED) FLOOR --�� DRAIN 1 99..'n ALARM CONTROL BOX CONNECTED TO ALARM (AUDIO AND VISUAL) 10 4" CAST IRON PIPE (OR EQUAL) MINIMUM PITCH 1/4" PER FT. ELEV. = 98.00 ELEV. = 97.17 SYSTEM PRORLE NOT TO SCALE (EXISTING) 2000 GALLON TIGHT TANK 24" DIA. HDCI FRAMES & COVERS V ROUGHT TO FINISHED GRADE rLEBARON LBW 288 OR EQUAL) VENT & VENTS ARE GRED �NSIDEUILDING RISING THROUGHOF NOTES: 1. ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO D.E.P. TITLE 5 AND THE TOWN'S RULES AND REGULATIONS FOR THE SUBSURFACE DISPOSAL OF SEWAGE. 2. ALL COVERS TO SANITARYUNITS SHALL BE BROUGHT TO FINISHED GRADE WITH 24_ HDCI FRAMES AND COVERS. 3. ALL COMPONENTS OF THE SANITARY SYSTEM SHALL BE CAPABLE OF WITHSTANDING H-20 LOADING. -_-- 4. ANY MASONARY UNITS USED TO BRING COVERS TO GRADE SHALL BE MORTARED IN PLACE. 5. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEEDED OR ZONING REGULATIONS. OWNER / APPLICANT IS TO OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY. 6. UTIUTIES SHOWN ARE APPROXIMATE ONLY, EXCAVATION CONTRACTOR IS TO CALL "DIG -SAFE" AT 1-888-344-7233 AT LEAST 72 HOURS PRIOR TO COMMENCING WORK ON SITE. 7. CONTRACTOR IS TO VERIFY GRADES AND ELEVATIONS AS WELL AS SITE CONDITIONS PRIOR TO COMMENCING WORK ON SITE. ANY VARIATION IS TO BE BROUGHT TO THE ATTENTION OF THE DESIGN ENGINEER IMMEDIATELY. B A13(EL 9).J 8. PARCEL IS IN FLOOD ZONES __ AS PARCEL - 9. LOT IS SHOWN ON ASSESSORS MAP _ 10. TIGHT TANK IS EXISTING AND CURRENTLY NOT BEING USED. 11. THE ALARM SWATCH SHALL BE CONNECTED TO A BELL AND LIGHT LOCATED INSIDE THE RESIDENCE. 12. AN ELECTRICAL PERMIT IS REQUIRED TO BE OBTAINED BY A LICENSED ELECTRICIAN IN ORDER TO INSTALL ALARM. 13. ALL CONTENTS OF THE TIGHT TANK ARE TO BE REMOVED BY A LICENSED PUMPING CONTRACTOR TO A LICENSED SEPTIC TREATMENT FACILITY. 14. APPROVAL IS REQUIRED FOR MISCELLANEOUS DISPOSAL (TIGHT TANK) INSTEAD OF AN ON-SITE SUBSURFACE DISPOSAL SYSTEM. 15. THE INSTALLER IS TO GIVE THE ENGINEER A MINIMUM OF 48 HOURS (2 WORKING DAYS) NOTICE FOR THE FINAL INSPECTION (NUMBER BELOW). 16. EXISTING TIGHT TANK WAS PERMITTED IN 1988 FROM A PLAN DRAWN BY ROBERT. BRAMAN, P.E. DESIGN CALCULATIONS NUMBER OF WASHING BAYS --�� GARBAGE DISPOSAL UNIT TOTAL ESTIMATED FLOW_ GAL./DAY (150 GAL/BAY/DAY X �_ BAYS) REQUIRED TANK CAPACITY 1500- GAL. ( 300 GAL/DAY X 5 DAYS) 2pOQ GAL ACTUAL TANK CAPACITY LEGEND: EXISTING SPOT ELEVATION 00.0 EXISTING CONTOUR----00--- FINAL SPOT ELEVATION 00.0 FINAL CONTOUR 00 SOIL TEST LOCATION UTILITY POLE __0_ -T ELEV.• = 98.42 LARM ACTIVATION LEVEL (A3/4 OF TOTAL DEPTH) 0 r ELEV. _ _ 92.42 FENCE �I POST - 1 11 17 0 jy FENCE X, POST FENCE \1I1/ �p �O �9" POST - O' SD N�° 2S X11, 20 EpGE GF FS F1-p,GGEpAGE�.11 65.33, CB 0� UP oN COMMAS 1�N EARN �' FND. g�pDpNGC OCA NO R, HARP �L cP_ 0 o \ /X5620 \'01 0 I � �P ' �G 0 cA � ' PIRATES COBE EAST INC. BK 4,102 PG. 12 PL. BK. 343 PG. 31 0 LOT 2A SALT MARSH = 11, 583 S0. FT. f 0.266 ACRES UPLAND = 185,408 S0. FT. 4.256 ACRES TO TA AREA = 196, 991 50. FT 4.522 ACRES SHAPE NUMBER = 2 4 MODIFIED SN. = 72.57 TOWN OF YARMOUTH 8K. 2,8J9 PG. 166 PL. BK 336 PG. 11 CB FND. 5"E CB CB �1 ] �45 2 FND. 15 FND. 216 i i i i i i i FND. i 5 AT 3 TOTAL AREA = 125,059 SO. FT. f \ 2.871 A CRSS \ SHAPE NUMBER = 20.43 X21 l/ENT'I,I EXISTING 2000 GALLON \ �0 o = TIGHT TANK __� O Exrs TING �n DC TRAP OOF _ ° UMP AND BACKFILL \0)_ �YIiENT p, UM3 LO cp ER o /P / NUN ONLY SNAULAT�O GAL \ R= 79.79 A=501.34' AREA =20, 000 S. FH \ SN=12.57 ' FND. , � 0 0 235 �p 165 �8 CB \ \ g•�0 FND. 20 v � 0 g 6pN N \ 1 i 9 E O APPROVED. BOARD OF HEALTH • 40 0 120 16# SO= YAR Cl�.►.`OUTH � QP��� LOCUS ROUTE 28 LO LO s LO LO DATE AULN I EXISTING TIGHT -TANK FOR DAVENPORT REALTY TRUST L°C.LOT 2A, #770 ROUTE 28 SOUTH YARMOUTH, MASS. 203 SETUCKE I KUAU 508- P. 0. BOX 713 385-6900 SOUTH DENNIS, MASS. 02660 °A�MAR. -31, 2014 SCALE 1" = 40' REV. �I JOB N0. 681O�OU