HomeMy WebLinkAbout891 Route 28 Proposed Septic Design 5TOP OF FOUNDATION 20 FT. MINIMUM FROM CELLAR ELEV. >. 99.50 10 FT. MINIMUM 10 FT. MINIMUM FROM SLAB OR CRAWL. SPACE DATE OF SOIL TEST GST CLEAN SAND SOIL TEST APPoN4�001 V• CONCRETE SOIL TEST DONE BY -WETSER ENGINE LNG p COVERS 4" SCHEDULE 40 PVC PIPE p LOAM AND SEEDp WITNESSED B`F B. G. MURPHY _ p OBSERVATION HOLE 1 ELEV.- 97.50 p OBSERVATION HO E 2 ELEV.- 97.90 MIN. PITCH 1/B" PER FL 2" LAYER OF PERCOLATION RATE < 2 MIN./INCH AT 54 INCHES PERCOLATION RATE 2 MIN./INCH IN C HORIZON 1/8" TO 1/2. 4" CAST IRON PIPE 97.50 MAX. WASHED STONE (OR EQUAL) MINIMUM X MIN. NOT T 3.00 REQUIREO PITCH 1/4" PER FT. Z 1 CU. FT. OF 3 CONCRETE FLOW LINEo ANCHOR X i 10" 94.50 �\ FE 96.50 V. 94.75 VOEL ° ° �3�_ BAFFLE ELEV. - 94.50 6" SUMP ELEV. - 94.3 = ° i� ELEV. - 93.17 DISTRIBUTION ELEV. - X LIQUID OUTLET_ 6 HIGH CAPACITY INFILTRATORS WITH boy DEPTH TEEBOX -�- STONE IN AN z 9� (TO BE PLACED ON FIRM BASE) TO BE WATER TESTED 4 FEET 14 INCHES y0 T 5 FEET 19 INCHES 1500 GALLON IF MORE THAN ONE OUTLET 11 X 48' X 10" TRENCH FORMATION 5.27 DEPTH HOP12 I TEXTURE COLOR MOTT. OTHER 0-11 A LOAMY SAND 10YR5/3 NO ROOTS 11-24 B LOAMY SAND 2.5Y7/4 ROOTS 4-132 Cl MEDIUM SAND 2.5YB/1 NO DEPTH HORIZ TEXTURE E' p 0 L t $ a p COLOR MOTT. OTHER 0-9 FILL PROJECT LOCATION 891 Va SOUTH R01- TE 28 iL'1 rrV YARMOUTH 9-19 A LOAMY SAND 10YR5/3 NO ROOTS 19-27 B LOAMY SAND 10YR6/6 ROOTS 7-126 Cl MEDIUM SAND 10YRB/1 NO. 50.(33�OQ � 6 FEET 24 INCHES in F` 1 7 FEET 29 INCHES 7 (TO BE PLACED ON FIRM BASE} SOIL ABSORPTION WELL M1W 29 X 98.7 $-V WATER ENCOUNTERED AT US!- ELEV. _ A7 n0 NO WATER ENCOUNTERED AT _-126' ELEV. _ 8 FEET 34 INCHES SEPTIC TANK ZONE NOEX-171 98.6 �'f\ A7-40 t 3/4" TO 1 1/2" CLEAN SYSTEM (SAS) t DOUBLE WASHED STONE FREE OF FINES k SILT ADJUST 1� 93.9 i USGS PROBABLE WATER TABLE ELEV. _ _67.910� �9 LEGEND: DESIGN CAL ULATIONS SEWAGE DISPOSAL SYSTEM PROFILE OBSERVED WATER TOM of (4/24/001)) ELEV. - 87.0 86.SQ �� 98 S • EXISTING SPOT ELEVA110N OQxO NUMBER OF BEDROOMS 4 NOT TO SCALE s ° EXISTING CONTOUR ----DO---- GARBAGE DISPOSAL UNIT ."> O FINAL SPOT ELEVATION TOTAL ESTIMATED FLOW FINAL CONTOUR ( 110 OAL/BR,/DAY X BR.) --4:40- GAL/DAY I 9 SOIL TEST LOCATION REQUIRED SEPTIC TANK CAPA TTY -$$Q- GAL I 9� UTILITY POLE -0- ACTUAL SIZE OF SEPTIC TAN14 GAL. TOWN WATER -WSOIL SOIL CLASSIFICATION I-- y� CATCH BASIN C11/ DESIGN PERCOLATION RATE 53- MIN./IN. GAS UNE EFFLUENT EFFLUENT LOADING RATE J14- GAL./DAY/S.F. ! \ x CLEAN OUT C LEACHING AREA 826.33 SQ. FT. CESSPOOL C.P. 0 (11X48)F(59X2X10/12) 4 ,/, j !/ 1,/� L�" I �C /<' �`, / p. / 9 9 \� LLACHING CAPACITY 626.33 X 0.74(AREA X RATE) 46141i GAL./DAY / 510(T(�i2� \ \ �F� RESERVE LEACHING CAPACITY 483.48 GAL/DAY 1=�`1 98.8 AREA �\ NOTES: ` j 1 PARI(IN \ 1. ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO D.E.P. f TITLE 5 AND THE TOWN OF AWW2 RULES AND REGULATIONS FOR THE DISPOSAL OF SEWAGE. ` i 2 -ALL COVERS TO SANITARYBSLRFACE U ITS SHALL BE BROUGHT TO I f 98 6j1 W 97.8 \� WITHIN 6. OF FINISHED GRADE. / \ 9 3. ALL COMPONENTS OF THE SA141TARY SYSTEM SHALL BE CAPABLE OF WITHSTANDING H-10 LOADING UNLESS THEY ARE UNDER OR WITHIN 10 FT. OF DRIVES OR PARKIN AREAS. H-20 LOADING SHALL BE USED UNDER OR WITHIN 10 FT. OF DRIVES OR PARKING AREAS. 4. ANY MASONARY UNITS USED To BRING COVERS TO GRADE SHALL i. BE MORTARED IN PLACE. I 99'2 REA 98'7 8.3 9 5. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH i o / RQQ� A \ 'Ua \ \� DEEDED OR ZONING REGULATIONS. OWNER / APPLICANT IS TO \ OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY. hp� �- 2500 GALLON o• 6. UTILITIES SHOWN ARE APPRO (MATE ONLY, EXCAVATION CONTRACTOR 0. BOX 98 5 SEPTIC TANK 98.6 \ �\ IS TO CALL 'DIG -SAFE" AT 1--888-344-7233 AT LEAST 72 HOURS �o PRIOR TO COMMENCING WORK ON SITE. 7. CONTRACTOR IS TO VERIFY GRADES AND ELEVATIONS AS WELL AS 98'1 / 99.E \ N SITE CONDITIONS PRIOR TO COMMENCING WORK ON SITE. ANY VARIATION IS ( 99 18 Lg \ ,�O IMMTEDIATELY. GHT TO THEATTENTION of THE DESIGN ENGINEER 8. PARCEL IS IN FLOOD ZONE B & C J X 98.4 \� 9. LOT IS SHOWN ON ASSESSORs MAP 4/ AS PARCEL 47 8.8 I .0 98.6 $ SP5// T 98.9 x8.1- �. ® 98.6 X 98.5OD \ 10K1 1500 GALLON SEPTIC TANK )� �t ,t X 98.0 �• _ �R� y1 �> - 1 1O o0 0, ,� `'\` 97.6 ®99.2 " { 6.9 0 99.2 D. BOX 1 / 4500 GALLON X 99.4 ®99.2 SEPTIC TANK 97.8 �^ 516 X 9S 1 99.2 500 GALLON SEPTIC 12 E0TIC TANK 998.7 3000 GALLON REA PUMP CHAMBER 1. / GRA55 A 98.6 SEPTlC CO 698.3 X 97.3 SOIL TEST 1 AREA / \ 8.5 w� I SOIL 98.3 90,799 S.F. �5P5 TEST 255 AR yE � x 98.7 98.1 GRA / / \ 8.0 1 ,. ��,1WQFJIU _ APPROVED: BOARD OF HEALTH 98.1 ` K�� v sI ...�4� T. A 3� / 505 1 k900 1 NU 819 AMAS % /0 -/2 D MANHOLE Q E DATE AGENT rn. AR o. N w WO \ h0 -cc (ASSUMED) ELEV. (ITAiIM -�. .� •,. . 8'3 PROPOSED SEPTIC DESIGN AND - 97.8 I r 0 ° BEST BUILDING EAST BUILDING DESIGN CALCULATIONS DESIGN CALCULATIONS . ' NUMBER OF BEDROOMS 10 NUMBER OF BEDROOMS 18 t ONE OFFICE GARBAGE DISPOSAL UN'T NO GARBAGE DISPOSAL UNIT TOTAL ESTIMATED FLOW TOTAL ESTIMATED FLOW ( 110 CAL./VL/DAY X 10 BR.) _1199_ GAL/DAY ( 110 GAL/81R./IDAY X_111_ BR,) 4 200 1189 GAL/DAY REQUIRED SEPTIC TANK CAPACITYCOQ GAL REQUIRED SEPTIC TANK CAPACITY �Q GAL ACTUAL SIZE OF SEPTIC TANK GAL. ACTUAL SIZE OF FIRST SEPTIC TANK 4500 GAL SOIL CLASSIFICATION L_ ACTUAL SIZE OF SECOND SEPTIC TANK :1 GAL DESIGN PERCOLATION RATE 5_9- MIN./IN. SOIL CLASSIFICATION _1_ EFFLUENT LOADING RATE -DJ-4- GAL/DAY/S.F. DESIGN PERCOLATION RATE S -,'i_ MIN./IN. LEACHING AREA _L SQ. FT. EFFLUENT LOADING RATE _Q.7} GAL/DAY/S.F. (30X50) LEACHING AREA 3 000 S0. F7. LEACHING CAPACITY (AREA X RATE) .11MM GAL/DAY 2 X (30 X 50) 1500 X 0.74 LEACHING CAPACITY (AREA X RATE) 2220 GAL/DAY RESERVE LEACHING CAPACITY =&Q GAL/DAY 3000 X 0.74 r RESERVE LEACHING CAPACITY 2220,S$i GAL./DAY 9.9 OVERALL SEMIC BASS RIVER DEVELOPENIENT FOR MOTEL. LLC E' p 0 L t $ a p PROJECT LOCATION 891 Va SOUTH R01- TE 28 iL'1 rrV YARMOUTH S;Gll 235 GREA 508- SOUTH 398-3922 ' fRD`rG WESTERN ROAD • ENNIS MASS..' 02660 " scALE 1" - 20' oATEAUG. 24, 200 REVISEDJOB NO. 50.(33�OQ �