Loading...
HomeMy WebLinkAboutApp# 16-A053LEGEND - 99- EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. -[99]- PROPOSED CONTOUR 1s8.4) PROPOSED SPOT EL. TH1 , ONE Fi/,F y � TEST HOLE 2, SLOPE OF GROUND Locus y6Te� UTILITY POLE . �0 o FIRE HYDRANT NOTE NOT ALL SYMBOLS MAY APPEAR IN DRAYANG 'THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM .• p y • • P. m SYSTEM PROFILE MAR ED WITH BE TAPE OR PROVIDE MIN. 20" DIAM. WATERTIGHT (NOT TO SCALE) COMPARABLE MEANS FOR FUTURE LOCATION. ACCESS COVERS TO WITHIN 6" OF FIN. GRADE 2" PEASTONE OR GEOTEXTILE CONCRETE COVERS TO WITHIN 3' GRADE EL 29.0 28.FILTER FABRIC OVER STONE 2 MINIMUM .75. OF COVER OVER PRECAST 2% SLOPE REQUIRED OVER SYSTEM 25.0 NOTE: 2' MIN. WALL PRECAST H-10 RISERS (7YP.) THICKNESS REOUIRED BLOCKS OR PRECAST RISERS 2'r 4"0SCH40 PVC MORTAR ALL H-10 6' MIN. SUMP PIPES LEVEL 1ST 2• COMPONENTS t2' MIN. INi. DIM. ENDS (TYP.) INV' L. 21.204' SIDES 22.0; 24.05'PTEE500 GAL H-10 TEE 23.80' EPTIC TANK -0 0 0 o WATERIEST D'BOX i° o°°o ' U0. LEVEL 000° 0 0 000 0°0°00 CAS BAFFLE . .?o�o,°,o°e,°,o?. X00°oao ®CME OR EQUAL _ FOR LEVELNESS ;00000°o° 21.47' 21.30' ,°° o°% °°°°°°°° 19.2 0,°0,°0,°0ooa°o? H-10 500 GAL. LEACHING CHAMBER BY ACME -PRECAST OR EQUAL 3/4"-1-1/2' DOUBLE WASHED STONE 4' MIN. (3) UNITS REQUIRED ALL AROUND PRECAST STRUCTURES 6" CRUSHED STONE OR MECHANICAL OVERALL DIMENSIONS TO OUTSIDE OF STONE: 33.50' X 12.83' COMPACTION. (15.221 [23) u (-L-5-% SLOPE) 3.6 13.0' BOTTOM TH-2 LOCUS MAP (_7 SLOPE) (� x SLOPE) NO GROUNDWATER FOUND SCALE 1"=2000'± FOUNDATION- 11 -SEPTIC TANK 65' D' BOX 12' LEACINFACILHTYG ASSESSORS MAP 118 PARCEL 23.3 LOCUS IS WITHIN FEMA FLOOD ZONE X (AREA OF MINIMAL FLOOD HAZARD) AS SHOWN ON COMMUNITY PANEL #25001CO579J DATED 7/16/2014 1 NOTES ZONING SUMMARY 1. DATUM IS NAVD 88 2. MUNICIPAL WATER IS PROPOSED ZONING DISTRICT: R-40 DISTRICT 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. MIN. LOT SIZE 40,000 S.F. MIN. LOT FRONTAGE 150' 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS MIN. FRONT SETBACK 30' TO BE AASHO H -1.Q MIN. SIDE SETBACK 20' 5. PIPE JOINTS TO BE MADE WATERTIGHT. MIN. REAR SETBACK 20' 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MAX. BUILDING COVERAGE 25% 310 CMR 15.000 (TITLE 5.) SITE IS LOCATED WITHIN THE AQUIFER 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO PROTECTION OVERLAY DISTRICT BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4' PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. REFERENCES DEED BOOK 16070 PAGE 243 PLAN BOOK 584 PAGE 96 OJALA f' C46502 SYSTEM DESIGN: Folin ��hJ Pond , ONE Fi/,F y � Stoney H171 Poo O � GARBAGE DISPOSER IS NOT ALLOWED Locus y6Te� �0 o J N PROPOSED 4 BEDROOM DWELLING n OJALA, P. E., Knob Hill R Whites Path c Blu DESIGN FLOW: 4 BEDROOMS ® 110 GPD 440 GPD (-L-5-% SLOPE) 3.6 13.0' BOTTOM TH-2 LOCUS MAP (_7 SLOPE) (� x SLOPE) NO GROUNDWATER FOUND SCALE 1"=2000'± FOUNDATION- 11 -SEPTIC TANK 65' D' BOX 12' LEACINFACILHTYG ASSESSORS MAP 118 PARCEL 23.3 LOCUS IS WITHIN FEMA FLOOD ZONE X (AREA OF MINIMAL FLOOD HAZARD) AS SHOWN ON COMMUNITY PANEL #25001CO579J DATED 7/16/2014 1 NOTES ZONING SUMMARY 1. DATUM IS NAVD 88 2. MUNICIPAL WATER IS PROPOSED ZONING DISTRICT: R-40 DISTRICT 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. MIN. LOT SIZE 40,000 S.F. MIN. LOT FRONTAGE 150' 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS MIN. FRONT SETBACK 30' TO BE AASHO H -1.Q MIN. SIDE SETBACK 20' 5. PIPE JOINTS TO BE MADE WATERTIGHT. MIN. REAR SETBACK 20' 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MAX. BUILDING COVERAGE 25% 310 CMR 15.000 (TITLE 5.) SITE IS LOCATED WITHIN THE AQUIFER 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO PROTECTION OVERLAY DISTRICT BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4' PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. REFERENCES DEED BOOK 16070 PAGE 243 PLAN BOOK 584 PAGE 96 29 } OJALA f' C46502 SYSTEM DESIGN: , 1STER ES Pte GARBAGE DISPOSER IS NOT ALLOWED i PROPOSED 4 BEDROOM DWELLING DANIEL A. OJALA, P. E., P.L.S. DESIGN FLOW: 4 BEDROOMS ® 110 GPD 440 GPD LOT 1 USE A 440 GPD DESIGN FLOW WETLAND - 15,737 SF± UPLAND - 43,575 SFf TOTAL - 59,312 SFf SEPTIC TANK: 440 GPD (2) = 880 USE A 1500 GAL. SEPTIC TANK LEACHING: d SIDES: 2(33.5 + 12.83) 2 (.74) = 137 GPD to BOTTOM 33.5 x_12.83 (.74) = 318 GPD C14 " TOTAL: 615 S. F. 455 GPD w W ¢ USE (3) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH 4' STONE ALL AROUND <o arm OZ> -O p U 1G- Of m LU�Clf- 00'l co c0 MA APPROVED DATE BOARD OF HEALTH < IL z DO o dd + z Do TEST HOLE LOGS _- WETLAND ENGINEER: CRAIG J. FERRARI, SE #13871 WITNESS: AMY VON HONE, RS ° I DATE: 3/9/2016 - I PERC. RATE _ < 5 MIN/INCH 4 CLASS I SOILS 0 /4 VEGE!A D��' m CO ELEV. 4 Q ELEV. \ DERING .. OW3 N p" 26' p" 25' 15 w <o� NWM< LS �A S 0 m w 10YR 3/1 10YR 3/1 o0 7" 3" 17 o cn < m B CT n m LS w o=)22" 10YR 5/4 24.2' I nec 29 } OJALA f' C46502 o No.40980 , 1STER ES Pte i BENCHMARK: MAG ELEVATION ;5 =25.6 NAVD88 [1 �4XC j21 j fes' M M W``1 M I I I '7- ,1 fr I Cp ,\ it II 25 T i i 3 .f �p9 44 8 I 1 i N ul LA SS -1350V 132.07' �l Or { L O� 3 ARCEL 29 3 Q OQ 2 c n o DAVID G. HERMAN o n -z ® E NICKERSON ARM WAY O- 0 C 17 ,� x� Ll:d) x z 3 M TH YARMO H, MA 02664 a.� m ^' za m < L4 -4D D) I 121 PAGE 70 3 r _0 O �i a rn DICE #16-057 { o � f RY• x • N s I 24. 1' 30 28 3� a 20. ' N rn V z � a z o �r- < n 1 z� 30J �m<0 mo(-) Atr�M0 0 2d ?S oT LO C) w _ V yY< J L0 } C1 n Oma Amo < 0 �z>-0 o<=m m 0 L�CJ:DOw <w0- a. z 0 0 PERC C 72" LMS C2 2.5Y 7/4 MS 2.5Y 7/4 144" 14' 144" NO GROUNDWATER ENCOUNTERED 01 1:9 >mm OF 19' 13' SON FARM WAY YARMOUTH MA PREPARED FOR ALEX KUHARENKA DATE: MARCH 16, 2016 Scale:1 "= 20' 0 10 20 30 40 50 FEET I of(508-362-4541 fox 508-362-9880 downcape.com 0 down cape engineering, inc. civil engineers land surveyors 939 Moin Street ( Rte 6A) YARMOUTHPORT MA 02675 16-057 OJALA f' C46502 o No.40980 1STER ES Pte DATE DANIEL A. OJALA, P. E., P.L.S. 01 1:9 >mm OF 19' 13' SON FARM WAY YARMOUTH MA PREPARED FOR ALEX KUHARENKA DATE: MARCH 16, 2016 Scale:1 "= 20' 0 10 20 30 40 50 FEET I of(508-362-4541 fox 508-362-9880 downcape.com 0 down cape engineering, inc. civil engineers land surveyors 939 Moin Street ( Rte 6A) YARMOUTHPORT MA 02675 16-057 A S.0ve �GCN 2oQF SN/NGLES — Ej iF-1 , ___ _ _ , L j rax. MLPf ew • .- tri t . �-- 'q 4L/r4-.. ._... _.Q ,yam r AV y ff T Z Z' FPI Fr F, F 11 - ,. X REx J- • OPO/= - � •a' F -- --.• - .- - — - �m �NvAr' -' � _ rot - -- -- - -- •---- --- -•--- -1 0 jZE%A/n/i)v6' I l is a i9G s/ s1 y I o t .4 i t { '�".'"'t�.'gX;¢•-" � ion? �-`�Z. 1All I ( � CVT •: F/ r, �- . D f 2 4 /3!G !�D oT yY/sirv+osaY � CB41 P�sT C+AS�t_DG 4 lfb.'�Rf MAY 0 2 2016 YARMOUTH OLD KING'S H;GHWAY Ec c`v m. PPROVED MAY 23 2016 . �'PP6E ilED t MAY 23 2016 TOWN CLERK pDlLES3.46 A/icKC.tt�s.v E`�itM ^.nsi4�( 1�A/Lv�o✓rPoi¢� FD: CIAMBRI�LLQzzc h'AwN �e• ORTE 4-1z —16 v, . ARCHITECTUMi DESIGN _.