HomeMy WebLinkAboutDecision 4354 Existing Conditions Site Plani_ '
NOTE:
THIS PLAN HAS BEEN COMPILED FROM CURRENT AND PAST FIELD WORK (1974-2011).
UNDERGROUND UTILITIES SHOWN ON THIS PLAN ARE BASED ON EXISTING PLANS OF
RECORD AND FIELD INSPECTION WITHOUT EXCAVATION. THE INFORMATION SHOULD BE
CONSIDERED APPROXIMATE AND MAY NOT BE COMPLETE. AT LEAST 72 HOURS PRIOR TO
ANY EXCAVATION FOR THIS PROJECT WORK, THE SITE CONTRACTOR SHALL MAKE THE
REQUIRED NOTIFICATION TO DIG SAFE, THE YARMOUTH WATER DEPARTMENT, THE
BARNSTABLE DPW AND OTHERS HAVING UNDERGROUND CABLE, PIPING OR APPURTENANCES
ON THIS SITE FOR VERIFICATION OF LOCATIONS.
LEGEND
15— EXISTING CONTOUR
3" CAL. RED MAPLE
+14.12. EXISTING SPOT ELEVATION
18
FINISH GRADE CONTOUR
CONIFER
[16.21
FINISH GRADE SPOT ELEV.
cape engineering,
Cl WL ENGINEERS
�.
HCP SYMBOL
fll}
SHRUB
MANHOLE
HYDRANT
CATCH BASIN
0-0
POLE LIGHT
SHORT POST LIGHT
DRAINAGE GALLEY
L
(WITH
COVER TO GRADE)
SINGLE POST SIGN
_ _
®
TWO POST SIGN
BENCHMARK
C-0�
UTILITY POLE
0
SOIL TEST
W_ EXISTING WATER MAIN
c EXISTING GAS MAIN
E EXISTING BURIED ELECTRIC
FO- EXISTING U.G. FIBER OPTIC CABLE
o EXISTING U.G. OXYGEN PIPING
o EXISTING U.G. TELEPHONE
NOTE: NOT ALL SYMBOLS APPEAR . ON DRAWING
PROJECT OWNER: CAPE COD HOSPITAL
C/O TERRANCE E. WHITTEMORE, CPE
DIRECTOR OF CONSTRUCTION & REAL ESTATE DEV.
CAPE COD HOSPITAL P.O. BOX 640
27 PARK STREET, HYANNIS, MA 02601
PH. 1-508-862-5104 FAX 1-508-862-7373
SEji r, PEAN
PROPOSED PARKING LOT
# 509 569 62, 66 BAY VIEW STREET
WEST YARMOUTH, MA
to"" was= CAPE COD HOSPITAL
27 PARK STREET, HYANNIS, MA 02601
20 0 10 20 40 80
( IN FEET) DATE: 5-20-2011 .
1 inch = 20 ft. REVISED: 6-17-2011 (SPR COMMENTS)
SHEET 3 OF 4- EXISTING CONDITIONS
d/1-7/11
98-168\-02-171 DOC PARK 2011.DWG
off 508-362-4541
fax 508 362-9880
down
in c.
cape engineering,
Cl WL ENGINEERS
LAND SURVEYORS
939 Main
Street - YARA40UTHPORT, MASS
98-168\-02-171 DOC PARK 2011.DWG