Loading...
HomeMy WebLinkAboutDecision 4354 Details Site Plan12"X3" CAPE COD BERM INTEGRAL WITH TOP COAT. OF ASPHALT 1.5" TOPCOAT MASS DPW TYPE 11 EXTEND GRAVEL 12" i i 2.5" BINDER (COMPACTED THICKNESS, TYP.) BEYOND BACK EDGE OF PAVEMENT O00000000000000U000 ",000 0 0 0 000000 0 0 0) 0 00000000000000 0 03)000 �O C0 0 0 0 0 0 CI 0 0 O 12" REPROCESSED ASPHALT GRAVEL- MDPW SPEC 10 TON VIB. ROLLER COMPACTED REMOVE TOP & SUBSOIL NOTE: REMOVE ANY FROST SUSCEPTIBLE MATERIAL TO A DEPTH OF 36" BELOW .FINISHED GRADE. REPLACE WITH NON FROST SUSCEPTIBLE MATERIAL (LESS THAN 10% DRY WEIGHT PASSING #200 SIEVE) NOTE: COMPACT ALL FILL IN 6" LIFTS TO 95% MOD. PROCTOR .DENSITY WITH 10 TON VIBRATORY ROLLER COMPACTER. PAVEMENT ' CR OSS SECTION NOT TO SCALE w GALV. THRUz CD - BOLTS U- 8"X8" P.T. POSTS 6'O.C. Y 0 GUARDRAIL w TYP. ALONG Z x RET. WALL MATCH EXISTING N \I/ W _ SEE PAVEMENT SECTION PROPOSED 2:1 FILL SLOPE COMPACT FILL TO 95% MOD. PROCTOR AND STAPLE EROSION 24" SHOULDER CONTROL JUTE NETTING OVER 6" LOAM & HYDROSEED i� I o AROA w OSFO 1 S<OpF �- 2 x c� x x W a 0 - J N J J ORIGINAL GROUND I FILL SLOPE CROSS SECTION NOT TO SCALE DEPTH (in.) TH1 0" O/A SOIL CLASS: I (SANDS, LOAMY SANDS) SANDY LOAM PERC RATE: < 2 MPI (5 MPI DESIGN) 10 YR 3/2 PRESOAK: 0:00:00-0:10:00 14" UNSUITABLE (24 GAL. < 15 MIN.) B < 9": 0:10:00 LOAMY SAND BOTTOM PERC: AT 48" 10 YR 4/6 UNSUITABLE 36" C GROUNDWATER CONTROLLED BY OUTLET MEDIUM SAND IN BOG- WATER IN BOG EL. 8.0 10 YR 5l4 126" DATE: 5/11/00 ENGINEER: MICHAEL S. FARIA, SE (DOWN CAPE ENGINEERING) WITNESS: BRUCE MURPHY, RS, CHO EXCAVATOR: ELLIS BROTHERS CONSTRUCTION TEST HOLE LOG NOT TO SCALE V H-20 H-20 HDPE CPP b H 120 HDPE C PRECAST ¢ 12"0 HDPE SLOPE 1% MIN. RISER SLOPE 1 % MIN. 2.0' (TYP.) 2.0' (TYP.) REMOVE 3' C.B. TRAP a PROPOSED ANY 12"� E BOW IPE H-20 UNSUITABLE SOIL SPLASH BLOCKS LEACHING GALLEYS ENCOUNTERE PROPOSED UNDER ALL INVERTS 0 (IF ANY) 1000 GALLON PRECAST 6" WASHED STONE UNDERNEATH FOR H-20 MANHOLE STRUCTURES 5' MIN. '0X6'-8" SHOREY SOLID AROUND STONE BASIN H-20 OR EQUAL 3/4" - 1 1/2" REPLACSAND SECTIONAL PLATE CLEANWASHED STONE (TYP.) 4' MIN AROUND GALLEYS DRAINAGE CROSS SECTION NOT TO SCALE NOTES: - 1. THE LOCATION OF EXISTING UNDERGROUND UTILITIES SHOWN ON THIS PLAN IS APPROXIMATE. PRIOR TO ANY EXCAVATION ON THIS SITE, THE EXCAVATING CONTRACTOR SHALL MAKE THE REQUIRED 72 HOUR NOTIFICATION TO DIG SAFE (1-888-344-7233) AND ANY OTHER UTILITIES WHICH MAY HAVE CABLE, PIPE OR EQUIPMENT IN THE CONSTRUCTION AREA FOR VERIFICATION OF LOCATIONS. 2. ALL CONSTRUCTION MATERIALS, COMPONENTS, AND METHODS EMPLOYED ON THIS PROJECT WORK SHALL CONFORM TO THE TOWN OF YARMOUTH SUBDIVISION REGULATIONS AND/OR THE MASSACHUSETTS DEPARTMENT OF PUBLIC WORKS STANDARD SPECIFICATIONS FOR BRIDGES AND HIGHWAYS AS AMENDED TO PRESENT. ALL SEPTIC REMOVAL WORK AND MATERIALS TO CONFORM TO 310 CMR 15.00 TITLE 5. AND YARMOUTH HEALTH REGULATIONS. 3. VERTICAL DATUM IS NGVD29 MSL DATUM. 4. NOTE THAT CONSTRUCTION OF THE DRAINAGE SYSTEM REQUIRES REMOVAL OF UNSUITABLE SOIL. UNSUITABLE SOIL SHALL BE REMOVED TO ITS MAXIMUM DEPTH FROM UNDER AND WITHIN 5' OF THE PROPOSED LEACHING COMPONENTSAND REPLACED WITH CLEAN SAND MEETING THE REQUIREMENTS OF 310CMR 15.255 (3). OWNER'S ENGINEER TO INSPECT SOIL CONDITIONS AND REMOVAL DURING CONSTRUCTION. 5. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHTO-H20 UNLESS NOTED. 6. THIS PLAN IS FOR PROPOSED WORK ONLY AND IS NOT TO BE USED FOR PROPERTY LINE STAKING. 7. 6" LOAM AND SEED ALL DISTURBED AREAS NOT PAVED, M6.03.0 SEED. 8. ALL DRAINAGE PIPING 12"0 H-20 CPP AT 1% PITCH UNLESS NOTED. 9. DRAINAGE COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY.OWNERS ENGINEER AND PERMISSION OBTAINED. 10. ALL STORMWATER RUNOFF TO BE RETAINED ON SITE. 11. LOTS TO BE COMBINED WITH 81X PLAN PRIOR TO OCCUPANCY. 12. COORDINATE UTILITY INSTALLATIONS/REMOVALS WITH APPROPRIATE VENDORS. 13. REMOVE ALL EXISTING UTILITIES AND SEPTIC SERVING EXISTING BUILDINGS. COMPACT CLEAN FILL' IN 6" LIFTS TO 95% MODIFIED PROCTOR DENSITY. 14. PARKING LOT LIGHTING SHALL NOT CAUSE GLARE FOR MOTORISTS, PEDESTRIANS OR NEIGHBORING PREMISES. 301.4.10 20' MAX. POLE HT., BURIED ELECTRIC SERVICE. 15. ELECTRICAL PERMIT REQUIRED FOR LIGHTING AND GATE, CONTRACTOR TO COORDINATE. 16. SEPARATE WRITTEN SPECIFICATIONS FOR WORK AND ORDER OF CONDITIONS APPLY, AND ARE INCORPORATED INTO THESE PLANS BY REFERENCE. 3/4" ELECTRICAL CONDUIT TO GUARD SHACK KEYPAD/ CARD SWIPE ' 12.0' (TYP.) 3C.B. TRAP ,12"0 HDPE PIPE 1000 GALLON PRECAST H-20 CATCH BASIN '0X6'-8" SHOREY SOLID BASIN H-20 OR EQUAL STAKED HAYBALES WITH TRENCHED IN SILT FENCE (TYP.) CAPE COD BERM 12"X 3" SECTIONAL PLATE COMPACT ALL BACKFILL IN 6" LIFTS TO 95% MOD. PROCTOR DENSITY. NOTE: 2' OF 1.5" DOUBLE WASHED STONE ALL AROUND BANKS OF GALL . 3" PEASTONE AND MIRAFI FABRIC OVER WASHED STONE AND DOWN SIDES. COMPACT ALL BACKFILL IN 6" LIFTS TO 95% MOD. PROCTOR DENSITY. H-20 RATED FRAME & COVER (3) REQ. 20' TOTAL HT. LEACHING STRUCTURES TO BE SET IN CLEAN SAND. 4" BITUMINOUS ASPHALT CONCRETE UNSUITABLE MATERIAL SHALL BE REMOVED FOR 5' MIN. ADDITIONAL 3/4" CONDUIT AROUND OUTER EDGE OF STONE IF ENCOUNTERED. 2.5" BINDER 1.5" TOP COURSE NOTIFY ENGINEER TO INSPECT WHEN EXCAVATING. 1% MIN, MASS DPW TYPE 11 NOT TO SCALE SYSTEM CONTROL 12" REPROCESSED ASPH. GRAVEL { OWNER WILL 0 000000000000 MASS DPW SPEC. COMPACT H-20 24" I.D. RISER o c�000 0000°00 TO 95% MAX. DRY DENSITY OR BUILT UP H-20 BRICK __ - _ MOD. PROCTOR MORTAR- ALL _COitiF•ONENT5�-(TYP.) I I WITH VIBRATORY ROLLER. CONTROL SHALL ALSO BE INCLUDED. a •: 3" PEASTONE & 00 .'°oo ° °b <..- L. . ° Q<D cCO °o° 000° o°o FILTER FABRIC do�0 00°o OVER STONE o v°d o°b 00D 0. 0o 0 °o0 0 °0 0 °o °o CATCH BASIN ,000,d°0 ° O,o° o'o° O,o00& DOWN SIDES o v° o b o oc5 poo o° e a o vo°o 0 0o v� 00.'3 OF TRENCH 00 °c� PO o ff° 00 00 0 °000°Oo0 °00 1 1 � o� o 0 00 00 0 ° a oo° Ooo° 00 00 ° °od (WITH COVER TO GRADE) Oa v" Oo 0, v, 0, p v od o ° d v °d -H O °oo °o O o0 0 00 (� oo°v o° ° 0 o p o° O,o 0 0° O in o p oo b o oc3 v o0 0 00 �oO °oO o00 a p o°oO v °° 0 Z) 00 O,o O,o o °o 0 o po 0 00 o O° 00 000 00 00 °°d O o° °° O° ° O° 000 00 00 00 ,° po Qo Oo°po po Do D 0 crod p ° b 0 ob O °oo O °o O °o ° EXISTING WATER MAIN oo �0 0o 0°0 0 0° 0°0o O d ooCid poc4 p0 0o °o o °coo °o °o EXISTING GAS MAIN ° °4°�o0 Oop O ooa,� 0°0 p o 0°00 O°a ° O O O o� 000 0o a a Oo Oo Ooo O„o CISdo d" � ob 0 � od p° b ppb °oop °O0 °00 ° EXISTING U.G. FIBER OPTIC CABLE oo"po 0 0001 h oo° 0° Oo°O0o OZ_' O d p°Cgb D°CS °d D° °d oOO po Oop bOS ° Q p0 O QO � OO dd°d p°d dd p°d o° u o0 0° 08 CF, p° 6 p° 0&8,:j' �O 0o° Oo K> Pjo 0 O °O O °Oo &8 o O o O O O PROVIDE PATIO BLOCK SPLASH PADS 2.0' MIN. END VIEW AND WASHED STONE UNDER ALL INVERTS, 8 S.F. MIN. DRAINAGE CROSS SECTION SCALE: N.T.S. INSPECTION SCHEDULE:' (BY OWNERS ENGI IEER, 24 HR. NOTICE REQ.) 1. FOUNDATION & SEPTIC' SOIL REMOVAL/SOIL COMPACTION 2. DRAINAGE INSTALLATION 3. COMPACTED SUBGRADE- PRIOR TO GRAVEL 4. GRAVEL LAYER AFTER COMPACTION 5. BINDER COARSE PAVEMENT 6. FINISH COARSE OF PAVEMENT 7. LANDSCAPING, TRAFFIC PAINT AND FINAL CLE�NUP. AGP -1710 "AMANO" BARRIER GATE (MOVE EXISTING UNIT) 6" SCH80 STEEL CONCRETE FILLED PIPE -PAINTED YELLOW TOTAL LENGTH 5'- EMBED 2' AND BACKFILL WITH CONCRETE TO TOP OF BINDER / (TYP.) 4' CHAIN LINK FENCE VINYL COATED 24"X24"X12" CONC. PAD 6" ABOVE DRIVE CLOSING LOOP LOCATION BY EQUIPM INSTALLER / CONTRACTOR TO PROVIDE -15 ADDITIONAL 3/4" CONDUIT TO GATE DETAIL BARRIER 20' FRONTR BUFFER ISLAND 3" CAL. RED MAPLE FOR FUTURE SPRINKLER NOT TO SCALE SYSTEM CONTROL { OWNER WILL CONIFER PROVIDE LOCATION) NOTE: FINAL PLACEMENT AND INSTALLATION OF GATE EQUIPMENT NOTE: CONTRACTOR TO PROVIDE LABOR TO MOVE EXISTING SHALL BE COORDINATED WITH OWNER. GENERAL CONTRACTOR BARRIER LIFT GATES AND ASSOCIATED SHALL INSTALL CONCRETE MOUNTING PAD, CONCRETE FILLED ACCESSORIES TO NEW ENTRANCE. PIPE BOLLARDS, AND ALL ELECTRICAL CONDUIT AS SPECIFIED 3/4" CONDUIT FOR A FUTURE SPRINKLER ALL TO MATCH EXISTING INSTALLATION. CONTROL SHALL ALSO BE INCLUDED. 2' d LIGHTING SPECS: QV SERIES POST TOP QVC540-M 400HPS 22"QUADRATE VERTICAL/ TYPE V 51000 LUMENS OR APPROVED EQUAL (RUUD ETC) 18'X 4 X .120 SQUARE STEEL (TENON) POLE CONDUIT AND ANCHOR BOLT POSITION TO BE OBTAINED FROM LIGHTING MFG. 24"0 BASE 8' LONG L 2' REVEAL ASTM A-79 GRADE 60 STEEL REINF. 1" MIN COVER ,-(4) #6'S VERTICAL MIN. 5000 PSI MIN CONCRETE 2" RIGID GALVANIZED STEEL SWEEP #3 STIRRUPS AT 12"O.C. CAUPER PARKING/BUFFER :E NFORCED NEW BLACK RUBBER SE (1/2" ID) JBLE STRAND 12 GA V ANNEALED TWISTED WIRE :E WRAP. LAP ENDS DOWN NOT STAPLE STAKES EQUALLY SPACED DUND TREE 2 1/2"x2 1/2"00' ACED 1'-0" FROM TRUNK, NNED DARK BROWN. NOES DRIVEN AT ANGLE AND ILLED VERTICAL WITH WIRE V 4'-0" BURIED N 3" DEEP SAUCER DEPTH SHREDDED BARK MULCH 'MOVE BURLAP FROM TOP ALF OF ROOTBALL )MPACTED SUB -GRADE )IL MIX TAIL LEGEND -15 EXISTING CONTOUR 3" CAL. RED MAPLE +14.12 EXISTING SPOT ELEVATION FINISH GRADE CONTOUR CONIFER FINISH GRADE SPOT ELEV. HCP SYMBOL SHRUB ° MANHOLE HYDRANT Y° CATCH BASIN 0-0 POLE LIGHT >Yc SHORT POST LIGHT FLOW DIFFUSOR (WITH COVER TO GRADE) -� SINGLE POST SIGN ® TWO POST SIGN BENCHMARK C_Q UTILITY POLE 0 SOIL TEST w EXISTING WATER MAIN G EXISTING GAS MAIN E EXISTING BURIED ELECTRIC FO EXISTING U.G. FIBER OPTIC CABLE 0 EXISTING U.G. OXYGEN PIPING o EXISTING U.G. TELEPHONE NOTE: NOT ALL SYMBOLS APPEAR ON DRAWING PROJECT OWNER: CAPE COD HOSPITAL C/O TERRANCE E. WHITTEMORE, CPE DIRECTOR OF CONSTRUCTION & REAL ESTATE DEV. CAPE COD HOSPITAL P.O. BOX 640 27 PARK STREET, HYANNIS, MA 02601 PH. 1-508-862-5104 FAX 1-508-862-7373 14 4 W IWA'. " I PROPOSED PARKING LOT # 50, 569 62, 66 PAY VIEW STREET WEST YARMOUTH, MA CAPE COD HOSPPITAL 27 PARK STREET, HYANNIS, MA 02601 20 0 10 20 40 80 ( IN FEET .) DATE: 5-20-2011 1 inch = 20 ft. REVISED: 6-17-2011 (SPR COMMENTS) �jH OF M,gq. 0, DANIEL tiG o DANIELAA. N� o� OJALA `OJALA CIVIL No, 4 o,46502 � a� Fcl .. ZONAL 6A 71 SHEET 4 OF 4- DETAIL SHEET off 508-362-4541 fax 508 362-9880 down cape engineering, Inc. C/VIL ENGINEERS LAND SURVEYORS 939 Main Street - YARMOUTHPORT, MASS. 98-168\-02-171 DOC PARK 2011.DWG