Loading...
HomeMy WebLinkAboutEngineered Plans - Rev. 2016Wells not shown exceed 150' from the proposed SAS BENCHMARK: EL. 52.73 (ASSUMED) TOP OF CONCRETE SILL PUMP 8 RETAIN EXIST. 1500 GAL. SEPTIC TANK 1. SOIL ABSORPT/ON SYSTEM FLOOR TO ADJUSTED H/GH GROUND WATER ELEVATION.• M/W-29 ZONE A ON /0//4//4 AT 9.7/ = Z P ADJUSTMENT. PER LOCAL APPROVING AUTHORITY (3/29//6) A l.2' ADJUSTMENT MAY BE USED. A VARIANCE OF 1.5' IS REQUESTED. SCALE l = 50 0 30 60 90 Moran 51.92 " CB/DH/FND 51,24 Permit valid for REPAIR OF SEPTIC SYSTEM ONLY; due to State and Local septic variances. Board. of Health review and approval is required for :any; future additions/ren ova tions/alterations to sewage facilities anal/or structures/dwelling, L 0T /d 25,162 SF f moo- C a 57 ACdn t cP O ' t)F •.• j f 52.16 ;; 06 is"'� .••�vj0� S 49 Z.• v 52.29/ O 10 V h Al ��\� ��\��� � ! OCL �L •• / , 48—HOUR ►1A Is Yarmouth Heallh Department APPRQ V ED/*/usf Dining LBedrm Area m° 'r PROPOSED 1500 - GALLON 65 0� 9g MONO. PUMP CHAMBER ' N 2 tS 52.52/ Rm PROPOSED CONTOUR 52.38 52.0 52.t,�••FDGF �'• PROPOSED LEACH/NG FIELD .0p J 0.- •.30.5' 50. 5'LONG BY /B. 0' WIDE CUL TEC CONTACTOR /00HD 52;51 Area SEWAGE PLAN 52. / 52.78 505%% << �\v�i CB/DH/FND / ` 52.08 aep i-CU.FT peg TH I THRUST � BLOCK PROPOSED 40 NIL. POLY O�Op4� p0 Gc LINER EL. 51. B TO EL. 48.8 _ • BM G 52.02'Tib• PROPOSED 5.0' OVER -DIG ' • ` X ' TO MIN. EL. 49.80 �� 52 20 j TPERC EST S, BOO 5, 43 \ 51.74 ,. \ (i)5, GARDEN s , AREA '= 52.64 \ 6' \ 'a�� VARIANCE REQUEST 3/0 CMR /5.405 (1) (A) / DEPTH TO GROUNDWATER 1. SOIL ABSORPT/ON SYSTEM FLOOR TO ADJUSTED H/GH GROUND WATER ELEVATION.• M/W-29 ZONE A ON /0//4//4 AT 9.7/ = Z P ADJUSTMENT. PER LOCAL APPROVING AUTHORITY (3/29//6) A l.2' ADJUSTMENT MAY BE USED. A VARIANCE OF 1.5' IS REQUESTED. SCALE l = 50 0 30 60 90 Moran 51.92 " CB/DH/FND 51,24 Permit valid for REPAIR OF SEPTIC SYSTEM ONLY; due to State and Local septic variances. Board. of Health review and approval is required for :any; future additions/ren ova tions/alterations to sewage facilities anal/or structures/dwelling, L 0T /d 25,162 SF f moo- C a 57 ACdn t cP O ' t)F •.• j f 52.16 ;; 06 is"'� .••�vj0� S 49 Z.• v 52.29/ O 10 V h Al ��\� ��\��� � ! OCL �L •• / , 48—HOUR ►1A Is Yarmouth Heallh Department APPRQ V ED/*/usf Dining LBedrm Area m° 'r Y Living -----52 oBedrmBedrn Rm PROPOSED CONTOUR ----N 2nd FLOOR Dining r FIVE FOOT SOIL OVER—DIG Bedrm Area SEWAGE PLAN m Y OF 4(43 MICHAEL S. LADUE No. 37500 P �FSS\o� a Rm E Bedrm m 1st FLOOR RICHARD Date ye � • o ( Lewis N 1 Pond ,Is 1 Seo G L y 14 Rd 4// Cope ° Rd Nantucket Sound LEGEND 3 Baldwin Lane West Yarmouth, MA Garage PREPARED FOR: Launie Nominee Trust 9 Birch Woods Drive Beverly, MA 01915 Deed CTF: 626956 Moran Engineering Associates, LLC P.O. Box 183 South Harwich, MA 02661 508-432-2878 MAP: 17 PARCEL: 12 SCALE: 1" = 30' JOB NUMBER: 14-161 1 SHEET: 1 of 2 TEST HOLE "D" BOX PROPOSED PUMP CHAMBER EXISTING SEPTIC TANK -----52 EXISTING CONTOUR r5_2_51 PROPOSED CONTOUR ----N WATER LINE OH OVERHEAD UTILITY LINE FIVE FOOT SOIL OVER—DIG HYDRANT SITE AND SEWAGE PLAN 3 Baldwin Lane West Yarmouth, MA Garage PREPARED FOR: Launie Nominee Trust 9 Birch Woods Drive Beverly, MA 01915 Deed CTF: 626956 Moran Engineering Associates, LLC P.O. Box 183 South Harwich, MA 02661 508-432-2878 MAP: 17 PARCEL: 12 SCALE: 1" = 30' JOB NUMBER: 14-161 1 SHEET: 1 of 2 EXISTING SEPTIC TANK MANHOLES WIN COWER TO GRADE To BE LOCAIED OVER OUTLET COVER R SMART FILTER: Com is REQUIRED TO BE LOCKING CR BOLTED TO RISERS EFFLUENT FLM IS REQUIRED TD BE FITTED WTTH AN "MOM HANDLE TO WITHIN tY OF THE ACCESS COVER. EFFLUENT FILTER ALARM TOP OF EL 52.00 FOUNDATION EL.53.25 COVERS TO BE WITHIN 6' OF GRADE - POWER SUPPLY FOR � ALARM I EL EFFLUENT FILTER Zabel A100- 8 x 18 W/ FILTER ALARM PROPOSED PUMP CHAMBER MANHOLES " COVERS TO GRADE TO BE LOCATED OVER PUMP FLOATS, 6: PPE MON FON MAINTENANCE PURPOSES ITZYYERS ARE REQUIRED TO BE LOC=G OR BOLTED 70 RISERS SEPARATE ELECTRIC LINES TO PUMP AND FLOATS c. ce M I 3't 6" BASE CRUSHED STONE "D" BOX DB -9 Low Profile EL 52.60 I I EL 52.60 4' SCI.40 P.V.L. CHIE&VALVE GATE -VALVE EL 51.70 EL 51.50 �-2' PVC OUTLET \ EL 50.00 5/16" DRAIN HOLE 27' - ALARM LEVEL 21' - PUMP ON 18" - PUMP OFF 56't LEACH FACILITY CULTEC CONTACTOR 100HD 4' SCH 40 PVC OR RISER\--\SDR-35 PVC PIPE4' PVC END CAP, END PLUG OR CLEANOUT. ``e sIIs eIIs oIIe IIISIIs eIIs elIslIelIs s In esmoocolI ol�',, -�- �t7.5' EACH UNIT (INSTALLED) 110' t LONGEST RUN 30.5' LENGTH INSTALLED 15.02' 4 t SHORTEST RUN NOTES FOR CULTEC EL 45.78 1.) Must be a CerLCUltec Installer, ADJUSTED HIGH GROIMD WATER 2.) Cultec No. 410 Filter Fabric or equal approved by Cultec required. PER LOCAL APPROVING AUTHORITY RUN FILTER FABRIC BELOW THE LENGTH OF FIRST UNITS TO ACT AS A SPLASH GUARD EXISTING SEWER LINE "D" BOX NOTES CULTEC CROSS SECTION SOIL MOTTLING NOT TO SCALE BELOW SLAB a• 7.5YR 3/2 f r EL 50.00 EXISTING e: CAST PON ALL EXTERIOR WIRING IS TO BE PLACED IN CONDUIT. LME & TEE - POWER SUPPLY FOR � ALARM I EL EFFLUENT FILTER Zabel A100- 8 x 18 W/ FILTER ALARM PROPOSED PUMP CHAMBER MANHOLES " COVERS TO GRADE TO BE LOCATED OVER PUMP FLOATS, 6: PPE MON FON MAINTENANCE PURPOSES ITZYYERS ARE REQUIRED TO BE LOC=G OR BOLTED 70 RISERS SEPARATE ELECTRIC LINES TO PUMP AND FLOATS c. ce M I 3't 6" BASE CRUSHED STONE "D" BOX DB -9 Low Profile EL 52.60 I I EL 52.60 4' SCI.40 P.V.L. CHIE&VALVE GATE -VALVE EL 51.70 EL 51.50 �-2' PVC OUTLET \ EL 50.00 5/16" DRAIN HOLE 27' - ALARM LEVEL 21' - PUMP ON 18" - PUMP OFF 56't LEACH FACILITY CULTEC CONTACTOR 100HD 4' SCH 40 PVC OR RISER\--\SDR-35 PVC PIPE4' PVC END CAP, END PLUG OR CLEANOUT. ``e sIIs eIIs oIIe IIISIIs eIIs elIslIelIs s In esmoocolI ol�',, -�- �t7.5' EACH UNIT (INSTALLED) 110' t LONGEST RUN 30.5' LENGTH INSTALLED 15.02' 4 t SHORTEST RUN NOTES FOR CULTEC EL 45.78 1.) Must be a CerLCUltec Installer, ADJUSTED HIGH GROIMD WATER 2.) Cultec No. 410 Filter Fabric or equal approved by Cultec required. PER LOCAL APPROVING AUTHORITY RUN FILTER FABRIC BELOW THE LENGTH OF FIRST UNITS TO ACT AS A SPLASH GUARD ELEV. 5208 PUMP CHAMBER DETAIL "D" BOX NOTES CULTEC CROSS SECTION SOIL MOTTLING NOT TO SCALE 51.33 E ECTRICAI NOTES: AN E ECTRICAL PERMIT IS REQUIRED 7.5YR 3/2 I. WHEN SYSTEM IS DOSED OR SLOPE OF INLET Granula PUMP: USE 1500 -GALLON PUMP PIPE EXCEEDS 0.08'/FT. INSTALL INLET TEE 9" MINIMUM COVER ALL EXTERIOR WIRING IS TO BE PLACED IN CONDUIT. CHAMBER MONO TANK CUT-OFF ONE INCH ABOVE OUTLET INVERT. 43.08 SHOREY MFG. Z5Y 6f4 GWE - 90' (El. 44.58) Loose, single grain 2. INSTALL OUTLET PIPES LEVEL 2 FEET SHOREY PUMP CHAMBER ALARM IN HOUSE ON SEPARATE CIRCUIT MINIMUM. FILTER FABRIC CYCLES REWIRED PER DAY - e 4'f BUOYANCY CALCULKnONS 3. PROVIDE A MINIMUM SUMP OF 6" BELOW TITLE 5 APPROVED FILL - DOSE VOLUME PER CYCLE REWIRED - 110 GALLONS OUTLET INVERT. 10.17'X 6.08'X 2.26'= 139.74 ft" DOSE VOLUME PER CYCLE PROVIDED - 110 GALLONS 4. INSTALL ACCESS PORT OVER "D" BOX WITH FILTER FABRIC 62.4 IbS/ft' x 139.74 ft = 8,719.7 Lbs uplift PRECAST CONCRETE OR EQUIVALENT AT FLOOR OF FIRST UNITS PUMP: MYERS SRM -4 WATERTIGHT RISER WITHIN 6" MIN. OF FINAL 11,833 lbs provided > 6,720 lbs uplift GRADE, PIPE AT INVERT DEEP HOLE LOGS DESIGN GENERAL NOTES 1.) ALL SYSTEM COMPONENTS SHALL BE INSTALLED IN ACCORDANCE W(i71LE 5 OF THE SANITARY CODE .& ANY APPLICABLE REGULATIONS. 2.) PRIOR TO BACK FILLING THE INSTALLATION, THE DESIGNER & HEALTH AGENT SHALL BE NOTIFIED FOR INSPECTION. 3.) ANY ALTERATIONS OF THIS DESIGN MUST BE APPROVED BY THE DESIGNER & BOARD OF HEALTH, IN WRITING. DATE: 11/5/14DESIGN DATA 4.) SYSTEM IS NOT DESIGNED FOR A GARBAGE GRINDER. DEEP OBERVA71ON HOLE I 1 TEST BY: RICK JUDD TIME: 03:00 5.) THE INSTALLER IS TO VERIFY THE LOCATTON(S) OF UTB-11TES, CESSPOOLS) AND SEWER INVERTS PRIOR TO CONSTRUCTION. 6.) ALL UNSUITABLE MATERIAL WITHIN 5 FT. IN ALL DIRECTIONS FROM THE SOIL ABSORPTION SYSTEM SHALL BE REMOVED & REPLACED W/CIEAN, ELEV. 5208 From Sur/eoe HOR. TEXTURE OR (MUNSELL) SOIL MOTTLING STRUCTURE CONSISTENCY, OTHER 51.33 r Ap Loamy Sand 7.5YR 3/2 NO Granula 4983 2r BW Loamy - Me6um Sand 7.5YR 414 NO Very Friable 43.08 106' C Medium Sand Z5Y 6f4 GWE - 90' (El. 44.58) Loose, single grain Bot. of Perc: 54" in C layer RATE. < 2 MINANCH (24 gallons in 6 min. 50 sec.) WITNESS: A. Von Hone, YHD 1. REQUIRED FLOW 6 BEDROOMS X 110 GPDB.R = 660 GPD COARSE SAND. 7.) ALL FILL MATERIAL UTILIZED FOR THE SOIL ABSORPTION SYSTEM SHALL BE CLEAN, COARSE SAND FREE FROM DELETERIOUS MATERIAL AND SHALL HAVE A PERCOLATION RATE OF LESS THAT 2 MINJIN. BEFORE & AFTER PLACEMENT. 2. SEPTIC TANK CAPACITY 660 GPD X 2=1320 GPD 8.) EXISTING CESSPOOL(S) TO BE PUMPED AND BACK FILLED PER TITLE 5 ABANDONMENT PROCEDURES. 9.) DURING INSTALLATION, THE CONTRACTOR IS RESPONSIBLE TO PROVIDE A SAFE EXCAVATION AREA USE (1)1500 - GALLON (EXISTING) SEPTIC TANK 10.) GROUND COVER OVER SEPTIC SYSTEM COMPONENTS SHALL NOT EXCEED 36". 11.) ALL GRAVITY SEWER PIPE SHALL BE 4" DIA. SCH 40 PVC UNLESS OTHERWISE NOTED. THE MINIMUM SLOPE OF 4" DIA. SCH 40 PVC SHALL NOT BE LESS THEN 0.01 FTRT. 3. LEACH FACILITY DESIGN: 12.) WHEREVER SEPTIC LINES CROSS WATER SERVICE LINES OR WHEN WATER SERVICE LINES COME WITHIN 10' OF THE PROPOSED SAS: PIPES SHALL 24-CULTEC CONTACTOR 10OHD (6 -ROWS OF 4 -UNITS) = 183 LF. BE CLASS 150 PRESSURE PIPE & SHOULD BE PRESSURE TESTED TO ASSURE WATER TIGHTNESS. COORDINATE WITH LOCAL WATER DEPARTMENT. 13.) PLACE MAGNETIC MARKING TAPE OVER ALL COMPONENTS. 183 LF. X 5.0 SF/LF = 915 SF. 915 SF X 0.74 GPD/SF = 677.1 GPD. CONSTRUCTION NOTES PER MASS DEP. STANDARD CONDITIONS FOR ALTERNATIVE SOIL ABSORPTION SYSTEM WITH GENERAL USE CERTIFICATION AND/OR 1. CONTACT OFFICE (508) 432=2878 MINIMUM OF 2 -DAYS PRIOR TO START OF PROJECT. ESTIMATED HIGH GROUNDWATER CALCULATION APPROVED FOR REMEDIAL USE (12/17/13). 2. THE EXISTING SEPTIC TANK REQUIRES PUMPING PRIOR TO CONSTRUCTION. RAISE SEPTIC (USGS/CCS METHOD) TANK & PUMP CHAMBER METAL OUTLET COVERS (BOLTED) TO GRADE. RAISE SEPTIC INDEX WELL: # MIW 29 ZONE: A TANK INLET COVER, PUMP CHAMBER INLET COVER AND DISTRIBUTION BOX COVERS TO 677 GPD PROVIDED > 660 GPD REQUIRED WITHIN 6" OF FINISHED GRADE. LEACHING FIELD REQUIRES FOUR INSPECTION PORTS WITH DATE OF READING: 10/14/14 DEPTH TO GROUNDWATER: 9.71 x IRRIGATION CONTROL BOX COVERS TO FINISHED GRADE. GROUNDWATER LEVEL ADJUSTMENT: 2.70-!" ACTUAL GROUNDWATER LEVEL @ SITE EL= 44.58 USE: 6=ROWS OF 4-CULTEC CONTACTOR 100HD. SET CHAMBERS SIDE BY 3. LOAM AND SEED LAWN IMPACT AREAS. A FINAL GRADE INSPECTION IS REQUIRED. ESTIMATED (MA)) HIGH GROUNDWATER LEVEL EL=47:28 SIDE. COVER ENTIRE FIELD WITH CULTEC 410 FILTER FABRIC. BACKFILL 4_ SEPTIC TANK INSPECTIONS: EFFLUENT FILTER WITH SMART ALARM (LOCATION TO BE LOCAL AUTHORITY ESTIMATED (MA)) HIGH G.W. LEVEL EL=45.78 TO THETOP OF COMPONENTS WITH CLEAN TITLE 5 FILL. PROVIDE 4 NOTED ON CONTRACTORS AS -BUILT CARD). INSPECTION PORTS PER PLAN. INSPECTIONS PORTS ARE REQUIRED TO 5. PUMP CHAMBER: EXTEND INLET TEE TO WITHIN 1.0' OF THE FLOOR OF THE CHAMBER. HAVE IRRIGATION CONTROL BOX COVERS TO GRADE. ALARM CONTROLS ARE NOT BE CONNECTED TO THE PUMP FORCE MAIN. ALARM CONTROLS s TO BE ON A SEPARATE HANGER OR POLE. 2" FORCE MAIN TO EXIT THROUGH OUTLET RISER. PUMP CHAMBER IS REQUIRED TO BE WATER TESTED MATH HEALTH DEPARTMENT AND DESIGNER PRESENT. 6. ONE CUBIC FOOT OF THRUST BLOCKING IS REQUIRED AT ALL FORCE MAIN ANGLE POINTS. 02015 Moron E.0 -bo Asex0lm LLC 7. DISTRIBUTION BOX IS TO BE A DB -9, LOW PROFILE. suBlEcr: 3 Baldwin Lone West Yarmouth, MA PREPARED FOR: Launie Nominee Trust ASSESSOR'S SCALE: MAP: 17 Not to Scale PARCEL: 12 DATE: 2/5/15 & 3/29/16 SHEET 2 of 2 Moran Engineering Associates, LLC 941 Main St., Harwich, MA PO Box 183, S. Harwich, MA 02661 508-432-2878