HomeMy WebLinkAboutEngineered Plan - 2016N SITE PLAN \ 1 `I SCALE: 1"=20' BENCH MARK ON CORNER OF CONCRETE PROPOSED SAS SON ELE1/ =100.00' (ASSUMED) 25'-0"L X 13'-0*'W X 24"D leaching trench using 2 H-10500-qat chambers with a of stone all around. p b 0 C 10"4, Existi cesgpool , ypical 99,21' E83 M. / 97.74' o 0 meq, ` O AO �e 3-2e MAIL ACCESS MMHME5 ow N Dining Kitchen Both GENERAL NOTES +� 1. ADDRESS: #367 LONG POND DRIVE Mulford St -rl 2. ASSESSORS NUMBER: MAP 68 PARCEL 138 N 0 Living 3. DEVELOPERS LOT: LOT 81 0: dames 'b� .o F 4. TOPOGRAPHIC INFORMATION WAS COMPILED FROM AN o a 0 ON THE GROUND INSTRUMENT SURVEY. 3 LD Monica St ?� 5. TOWN WATER IS PROVIDED TO SITE & SURROUNDING PROPERTIES. +_ -C 6. REFERENCE PLAN: PLAN BOOK 112 PAGE 151 1 +o-' W SITE •� 7. NO WETLANDS ARE LOCATED WITHIN 150 FEET OF THE PROPERTY. J S. NO POTABLE WELLS ARE LOCATED WITHIN 150 FEET OF SAS. Long pond Road FIRST FLOOR 9. UTILITIES WERE LOCATED BY DIGSAFE. 10. THIS DESIGN PLAN SHALL BE USED FOR SEPTIC INSTALLATION PURPOSES ONLY. LONG POND BakDesign Calculations Number of Bedrooms: 3 Existing LOCUS Room Garbage Disposal: Not allowed with this design ��� Desi n Flow: 3 Bedrooms x 110 gal/bedroom =330 gpd NO SCALE g Unf. Sewing 0 roti LRil. Rm Application Rate for <2 min./inch = 0.74 gal/sq. ft. 'ki,660 `fl.o .o Septic Tank Required: 330 gpd x 200% = gpd. USE 1,500 GAL MIN. PER TITLE V `+c°tio Septic Tank Provided: 1,500 gal. H-10 septic tank ' �°P,� Leaching Capacity Required: 330 gpd x 0.74 gal/SF = 446 SF • o BASEMENT LEVEL Proposed Leaching Structure: 1-25'x13'x2' Leaching Trench I Bottom Leaching Area Provided = 325 Sq Ft. Side Leaching Area Provided _ 152 sq. ft c`-{.���Jllll �� • �, Total Leaching Area Provided - 477 sq. ft.! p?�IIIII ' Leaching Capacity Provided =477 sq. ft X 0.74 gal/sq.ft.=353 gpd. > 330 gpd. 9� lot-, Permit valid for REPAIR OF SEPTIC SYsTF:M ONLY, due to State. anti I oval septic variances. LOT B1 Board of Health review and Approval is required for PPROX. A=11,7 sq.ft. CA PERK TEST & SOIL EVALUATION CONSTRUCTION NOTES any future additions/renovations/alterations to Date of Perc. Test & Soil Eval.: April 21, 2016 1. Contractor is responsible far Digsafe notification sewage facilities and/or structures/dHvUing.. Test Performed By: Glen E. Harrington, R.S. p • WITNESSED BY: Amy Von Hone, R.S., CHO, Asst. Health Agent and protection of all underground utilities and pipes. x EXCAVATOR: Scott Campbell Yarmouth Ilea{Ih I)cparttnCut PERK RATE: LESS THAN 2 MPI in C1 2. The septic tank and distribution box shall be set level on 6" of 3/4"-11/2" stone.�s �� �� ` S 0- 3 Backfill should be clean sand or gravel with no 1HE ACCESS COVERS FOR 1HE SEPTIC TANK. vuluff Dist R TKkITM 6 � EA T SHALL BE INSTALL TUF-TITS GAS BAFFLE OR EQUAL ON ALL OUTLET TEE ENDS STEEL REINFORCED PRECAST CONICRETE PLAN VIEW 3-W MWAN E 00411ts •.i. 4 s ..3 • n*L •�ce'{ ,+� nor Ir Er 2• MbL Nd to allot 4r aRntEi 11111. M '� s -r • w. w * U" � CROSS-SECSjOjy END -SECTION TYPICAL 1500 GALLON H-10 SEPTIC TANK NOT TO SCALE USE WIGGIN PRECAST OR EQUAL 8 to v�a�w \� V O� 0 Test Hole No. 1 10' min. from *NOTE: ALL PIPES ARE TO BE 4" DIA. SCHEDULE 40 P.V.C. ELEV. Existing House house to septic tank USE "GGIN KNOCKOUTS 5 HOLE H-10 OU,LE, 12' INET z 01ST. BOX DOS71NG GRADE ELEV =101'1 OR EQUAL Finished grade over CELLAR WALL ;r Bw Tank Covera shoo be D -Box cover shall be within 6" of finished grode within 6" finished grade O Line 1) 100.0' S - 0.02' ft. S ­ Level for r S-0.01'/ft tom5/e PROPOSED 1500 GAL PLAN -SECTION CROSS-SECTION 8 to v�a�w \� V O� 0 Test Hole No. 1 SOILS I ELEV. - loanA KNOCKOUTS - 5s OU,LE, 12' INET LEGEND EXISTING CESSPOOLS Bw '�• --�,�• + Y O Imity .oa z' tom5/e PROPOSED 1500 GAL PLAN -SECTION CROSS-SECTION o 0 o H-10 SEPTIC TANK C1 DISTRIBUTION BOX X 104.46 a=/+d stones over 3" in size. 4. This system is subject to inspection during installation by Glen E. Harrington, R.S...CJ_W-1 5. The contractor shall install this system in accordance ,tm Uate with Title V of the Massachusetts Environmental Code BEGIN SOAK: 00:00 and the Regulations of the Town of YARMOUTH. END SOAK: 9 MIN. 01 SEC. 6. Provide a Wiggin Precast H-10 1,500 -gal septic tank, H-10 DB -5 D -Box and PERK RATE: < 2 MPI in Cl 2 H-10 500 -gal. chambers or equal WITH 24 GALS APPLIED. g _ 7. No vehicle or heavy machinery shall drive over the septic system unless noted as H-20 septic components. 8. Install gas baffle or equal on septic tank outlet tee end. 9. All existing inverts and site conditions shall be verified by contractor. 10. Provide 4" diameter SCH 40 PVC vent with carbon filter if SAS is installed greater than 4 feet below grade. ll be umped and removed. No GROUNDWATER ENCOUNTERED 11. The existing cesspools Q p 12. If, during installation the contractor encounters anythe installer shall halt installation and immediately from those shown on the soil log or in the design, soil conditions or site conditions that are different notify Glen E. Harrington, R.S. 13. Designer not responsible for undocumented septic components. REQUEST FOR LOCAL UPGRADE APPROVAL ALL ouTLEr PIPES FROM THE 1. 310 CMR 15.405(b) - A variance is requested to allow the proposed soil absorption DISTRlsunON Box SHA BE 16, CONCRETE COVER system to be installed 15 feet from the existing bulkhead in lieu of the required 20 feet. SET LEVEL FOR Al `• 5 - 5" OUTLET `.,r x• Ss:'. Y KNOCKOUTS - 5s OU,LE, 12' INET LEGEND EXISTING CESSPOOLS i:' ;,r '�• --�,�• + Y O To BE PUMPED AND REMOVED z' PROPOSED 1500 GAL PLAN -SECTION CROSS-SECTION o 0 o H-10 SEPTIC TANK 5 HOLE DISTRIBUTION BOX X 104.46 DENOTES SPOT HEISTING NOT TO SCALE 95 EXISTING CONTOUR DEEP TEST HOLE Approx. location _W W_ existing water line One chamber cover shall be within 6" of finished grade Min. 2" 1/8"-1/2" Double -Washed Stone E ' t' Grade = 101't or geo-textile filter: cloth PROPOSED SEPTIC SYSTEM REPAIR PREPARED FOR CARDINAL CONSTRUCTION AT #367 LONG POND DRIVE YARMOUTH, MA em=27o slope away xls Ing OWNER: SILVA IDELSON DUMONT 14 /GAS B 1 SEPTIC TANK .: •,. I 1,500 GAL PROFILE.61 of STONE 6" OF 314"-Illr STONE 3/4"-14" Double -Washed Stone SYSTEM • • Scale op of Peastone Elev.�98.5 � �OF.�9 �f� Invert Elev=98.00'��� ��' PREPARED BY: " Glen E. Harrington, R.S. .4 ���_� •��� 9 Leda .Rose Lane .' @ �10r VSs � ' ►I�04, Marstons Mills, MA 02648 Bottom of Leach d 0• g Facility Elev.=96.00 .�� �y `IJ 1 ; Q • =" IgATTF1c41 C. �, .1, Lc �d Tel: 774-238-1813 1.5 provided (5 Min.) T- o C05TA �j d',gr�r*ST $P EMAIL: GHARR88®HOTMAIL.COM iottom of Test No. 522112 "' /TA sole #1 Elev.=90.45' (�as�o�fl SCALE: 1 "=20' DRAWN BY: GEH DATE: 30 APR 2016 'stlR'1 DATUM: ASSUMED FILE: CampbellLongPond SHEET 1 OF 1