HomeMy WebLinkAboutEngineered Plan - Rev. 2016Z ASSESSORS MAP: ---///7
PARCEL: ;2 `
FLOOD ZONE:
REFERENCE:
LOCATION MAP
411
�t
A
1 Q
PV
TEST HOLE LOGS
SOIL EVALUATOR -.1 ►�1I1 , Ir Ill �%5G
WITNESS- AM V5 1 tkf
DATE: ),m fel
PERCOLATMON RATE:c:
TH-1 TH-2
y8 )-0W 11�
1) The installation shall cornt:,� with Title V and Town of �VADL 1113oard o,t.
I lealth Regulations.
2) The installer shall verify the location of utilities, sewer inverts and septic
components prior to installation and setting base elevations.
3) All gravity septic piping to be 4 inch Sch 40 PVC at 1/8" per foot. The first
two feet out of the d -box to the leaching shall be level.
4) This plan is not to be utilized for property line determination nor any other
purpose other than the proposed system installation.
5) All septic components must meet Title V specifications.
6) Parking shall not be constructed over H 10 septic components.
7) The property is bounded by property corners and property lines.
8) The property owner shall review design considerations to approve of total
design flow and number of bedrooms to be considered for design. Receipt
of payment for the plan and installation based on the plan shall be deemed
-� approval of the design flow by the owner.
9) The existing leaching or cesspools shall be pumped and filled with material
3� per Title V abandonment procedures. Those within the proposed SAS shall
be removed along with contaminated soil and replaced with clean sand per
—5,2 ,
Title V specs.
\� 10) System components to be 10 feet from water line. Sewer! -nes crossing the
water line shall be sleeved with 4 inch SCI I 40 PVC with ends grouted if
U ,%� ..__� �. —�� applicable. The proposed SAS is being installed below the water service
�= '� line. The line is to be sleeved as aforementioned and maintained in
4J, - - — -`--' place.
SEPT I C SYSTEM ly
D E S GN 11) If a garbage grinder exists it is to be removed and is the responsibility of the
i owner to ensure such.
FLOW ESTIMATE 12) The installer is to take caution in excavation around the gas line if such
exists.
BEC+ROOMS AT I r GAL DAY/BEDROOM - 11 D GAL/DAY 13) Tne installer shall verify the location, quantity and elevation of the sewer
o%--- 7-0 0 �1 l I 1,,�- lines exitin? the dwelling prior to the installation.
b I -F0� PL11 � ��� Cl✓xl'ST?l'�- -� �� W _J� �i ,� 14)This plan is representative only that a system can fit on a property meeting
SEPTIC TANK
Title V requirements.
/ q
(d GA'L/DAY x 2 DAYS - 15)
9 3 3 `i� �{ I 7jL I���. �r�It Vii.+ (.�1W'/iu`^�'' GA
0 0 � , �
o I I I I b ( USE I+..��GALLON SEPTICW
-SUI E A6S0ITPTTON—SYSTEM
'0 b
-
�` a
Pop S I DE AREA:
+� j �✓ 3�LCY�J �9r°f'2� 7'� BOTTOM AREA: zZ X, 0 -7
SEPTIC SYSTEM SECTION
oP w f�uw 411u -
�L�G�IGu
=QY�t]�_el
n'l ..f h/ 1 1 ) iT I0/
o
G an1�-gUTt�� �,� ti •
L ---- �-
-. ..........
0,15.0-11-41
<rIL. cob b 6 1
.00
DATE
DAVID
MASON m
`v No. 1066 y
F_
1 f' 0u /4�cw�
;,
IL
0
Tb 2 OSOGAL 7
7,17,
/P,EPTIC TA%K. vo
15 � �?V -; tjjgP,;_ W ZIP
SITE AND SEWAGE PLAN
LOCATION.
Yarmouth Henith Departrsnt
rp
E D PREPARED FOR
1`d nae
' ��t� H I,.II��Ij V
CALF :
DAV I D '13— MASON F6 DATE:L-2�2-/ZD14
DBC ENVIRONMENYAL DESIGNS
HEALTH AGENT EAST SANDWICH. MA
(508) 833-2177