HomeMy WebLinkAbout796 Route 28 Proposed DetailsHYDROCARBON TRAP (HOOD) W/WEEP HOLE 6.33 4.58 0.50 6.00 -� DEEP SUMP CATCH BASIN (SCB-1000-H-20 1000 GAL. SOLID CATCH BASIN ON 6" SOLID PAD) 1000 GAL MONOLITHIC TANK IN 1500 GAL H-20 PRECAST SECONDARY TANK FOR FLOOR DRAIN, MANHOLE EL 11.27 ALARM CONTROL PANEL ON SEPARATE CIRCUIT, ELECTRICAL PERMIT REQ'D. 4" Cl VENTS THROUGH ROOF PROPOSED BUILDING SLAB EL 11.60 EL PER PLAN ELEV 6.20 SEE PLAN 1.00 ID HDPE EL 6.10 CORRUGATED DRAIN PIPE OR EQUIV. GROUND WATER ELEV 1.8 AT SOIL TEST OCT 1979 ELEV 1.12 SIGN "NON- HAZARDOUS WASTE WATER HOLDING TANK-U�ARBY SANITARY TEE OR CROSS, TYP. 4" FLOOR DRAIN, 4" CLEANOUT • 4 1.00' ID HDPE CORRUGATED & PERFORATED - DRAINAGE PIPE OR EQUIVALENT LOCATED PER PLAN, PLUG END SEE PLAN 9.10 MIN 1.00 ID HDPE CORRUGATED DRAM PIPE MANIFOLD PER PLAN VIEW -I- EL 7.60 2.00 EL 5.60 LPLACE GEOTEX ILE FILTER CLOTH 0.5 J ON BOTTOM, T P, AND SIDES OF PROB. HIGH GROUND 3/4" - 1 1/2" WASHED STONE - WATER ELEV 5.10 WASHED STONE REQUEST 0.5 FT. VARIANCE TO 4.60 SEE PLAN DRAINAGE DETAILS JNTS) 4" C. TO R FLOOR DRAINS, VENTS, AND PIPING TO TANK TO BE 4" CAST IRON INSTALLED PER 248CMR, THE STATE PLUMBING CODE 4„ 4" FLOOR DRAIN CLEANOUT W SCREEN EL. 11.50 .00 1 25� 6" ROOF DRAIN EXISTING 4 PLCS. BENCHMARK: CATCH BASIN MONITORING WELL RIM 9.18 _50% .52 NGVD 88 5.0 21.5'x21.5'. LAY CONCRETE MASONRY UNITS TIGHTLY BUT UN - MORTARED BETWEEN TANK TOPS TO PREVEI'T "rT 30" HDCI WATERTIGHT GASKETED MANHOLES 4" CLEANOUT TYP INTEGRALLY CAST --- EL 9.75BOOTS, TYP 2 4" C.I.TO 4" Cl R !F VENT EL 9.52 TANK 4" Cl FLOOR DRAIN EL 8.43 EL 10.25± Cl P -TRAP FLOOR ELEVATIO VIEW �.�+ as f - i F, DRAINAGE PLAN, NTS .,A\1 13 7.67 PHGWL SET LEAK DETECTOR EL 5.1 ON BOTTOM EL 3.60 GW Q SOIL TEST EL 1.82 INSTALL ON 6" GRAVEL OVER NATIVE SOIL OR MECHANICALLY COMPACTED BASE 0.67± 2.50 k�r f- 0.50 r 4.00 ALARM 00 BUOYANCY CALCULATION DISPLACEMENT 1500 GAL TANK 11.5'x6'x6.83'x62.4 #/FT^3 =29,536#FW WEIGHT 1500 GAL TANK 24,342# WEIGHT 1000 GAL TANK 7,268# TOTAL WT> 31,610# MARGIN 2,074# NO BALLAST REQ'D. ---J 2.50 I►- 2"ALARM CONDUIT I. 7.67 5.98 1000 GAL MONOLITHIC _. HOLDING TANK 6.00 - 1500 GAL H2O MONOLITHIC - 11.50 SECONDARY CONTAINMENT ELEVATION VIEW TANK SECTION VIEW ACME NHWWHT 102 PRIMARY 1000 GAL MONOLITHIC TANK SECONDARY 1500 GAL H2O MONOLITHIC TANK PROPOSED DETAILS LOCATION: 796-798 RT 28 SO. YARMOUTH MA MAP/PARCEL: 3350 PREPARED FOR: MARIE CARONISILVER CLOUD TOWING SCALE: NOTED DATE: 08-11-15 rev 05/11/16 DAN A. SPEAKMAN CONSTRUCTION LAND SURVEYING & TITLE V ENGINEERING DIV. 15 SPEAK WAY, N. HARWICH, MA 508-432-5565 SHEET 2 of 2 a