Loading...
HomeMy WebLinkAboutEngineered Plan - Rev. 2016PROVIDE MIN. 20" DIAM. WATERTIGHT ACCESS COVERS TO WITHIN 6" OF FIN. GRADE uiK"w w -7r nr rnvrQ nvra carrrecT SYSTEM PROFILE (NOT TO SCALE) 2" PEASTONE OR GEOTEXTILE FILTER FABRIC OVER STONE ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. CONCRETE COVERS TO WITHIN 3" GRADE 2% SLOPE REQUIRED OVER SYSTEM 1,14.0 NOTE: 2" MIN. WALL BLOCKS OR X 99.1 PRECAST H-10 THICKNESS REQUIRED PRECAST RISERS PROPOSED CONTOUR RISERS (TYP.) 4-0S CH40 PVC ENTS H-10 2'0 21.91 PROPOSED SPOT EL. s" MIN. SUMP PIPES LEVEL 1ST 2' 4' +' 12" MIN. INT. DIM. ENDS (TYP.)INV'S FL. 20 1 SIDES 21.1 1 ' 10" **EXISTING 14" °°°°°°°° ojjMORTAR p�0� SEPTIC TANK TEE*20.51' "' a®°o°o°o°o ®®®®aaoa O —!]0®0 �®®®oa®oo®® uo '0°0°0°0°TEE >o-000.00 :: °°°°°°°°°°°° WATERTEST D'BOX o >0°0°0°0° a�®oo��aa®� �oaoo�®aoao >o�o�o�o� °°°°° GAS BAFFLE'.-.. °°°�°� °°�°O FOR LEVELNESS �i >00000000 ®®®0�®®®�0® ®�o�aaoaao® .00000000 18.11 ' 20.21' '°°°°0°0° 20.38 °°°° °°°°°°°° LH-20 BY ACME PRECAST OR EQUAL. 500 GAL. LEACHING CHAMBER a 3/4"-1-1/2" DOUBLE WASHED STONE 4' MIN. (2) UNITS REQUIRED � ALL AROUND PRECAST STRUCTURES 6" CRUSHED STONE OR MECHANICAL OVERALL DIMENSIONS TO OUTSIDE OF STONE: 25.00' X 12.83' • COMPACTION. (15.221 [21) ac,¢ • 14.0' BOTTOM TH-1 NO GROUNDWATER FOUND (--!—% SLOPE) FOUNDATION— EXIST SEPTIC TANK 13' — LEGEND _99— EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. —[991— PROPOSED CONTOUR 198.41 PROPOSED SPOT EL. TH1 a 0 } TEST HOLE 2�-_ SLOPE OF GROUND C -Q-) UTILITY POLE o Y FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING TEST HOLE LOGS ENGINEER: CRAIG J. FERRARI, SE WITNESS: AMY VON HONE, RS DATE: 5/4/2016 PERC. RATE _ < 2 MIN/INCH CLASS 1 SOILS 13871 ETI ELEV. 0" 24' A LS 1OYR 2/2 910 B LS 14„ 1 OYR 5/8 22.8' C PERC MS 2.5Y 7/4 120" I I 14' NO GROUNDWATER ENCOUNTERED BICE # 16-123 (-!—% SLOPE) D' BOX 12' LEACHING FACILITY ***13.11' VERIFY AT TIME OF INSTALL PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL **INSTALLER SHALL CONFIRM MINIMUM SEPTIC TANK UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS SIZE AT 1500 GALLONS AND ITS SUITABILITY FOR PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM RE -USE. REPLACE WITH 1500 GALLON H-10 SEPTIC TANK IF NOT SUITABLE (OR H-20 SEPTIC TANK IF IT WILL BE SUBJECT TO VEHICLE LOADING). NOTES 1. DATUM IS NAVD 88 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8- PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-20 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR.PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR • TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. Scale:1 "= 20' 0 10 20 30 40 50 FEET FLOOR PLAN NOT TO SCALE Yarmouth Health Department APPROVED r� wine Date LOCUS MAP NOT TO SCALE ASSESSORS MAP 132 PARCEL 118 SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 3 BEDROOMS @ 110 GPD = 330 GPD USE A 330 GPD DESIGN FLOW SEPTIC TANK: 330 GPD (2) = 660 **RE -USE EXISTING 1500 GAL. SEPTIC TANK LEACHING: SIDES: 2 (25 + 12.83) 2 (.74) = 112 GPD BOTTOM 25 x 12.83 (.74) = 237 GPD TOTAL: 472 S.F. 349 GPD USE (2) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH 4' STONE ALL AROUND APPROVED DATE 5-7-5-1c, DATE DANIEL A. OJALA, P.E., P.L.S. TITLE 5 BOARD OF HEALTH SITE PLAN OF MA #68 OLD CHURCH STREET YARMOUTHPORT, MA PREPARED FOR DONALD FRENIERE DATE: MAY 16, 2016 REV: MAY 23, 2016 I off 508-362-4541 fax 508-362-9880 downcope.com down cn�e engineering, inc. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 16-123 %der- . a c a 0 �oS, Locus o T a c ?. o � a a �/fie • 4 ac,¢ • �o LOCUS MAP NOT TO SCALE ASSESSORS MAP 132 PARCEL 118 SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 3 BEDROOMS @ 110 GPD = 330 GPD USE A 330 GPD DESIGN FLOW SEPTIC TANK: 330 GPD (2) = 660 **RE -USE EXISTING 1500 GAL. SEPTIC TANK LEACHING: SIDES: 2 (25 + 12.83) 2 (.74) = 112 GPD BOTTOM 25 x 12.83 (.74) = 237 GPD TOTAL: 472 S.F. 349 GPD USE (2) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH 4' STONE ALL AROUND APPROVED DATE 5-7-5-1c, DATE DANIEL A. OJALA, P.E., P.L.S. TITLE 5 BOARD OF HEALTH SITE PLAN OF MA #68 OLD CHURCH STREET YARMOUTHPORT, MA PREPARED FOR DONALD FRENIERE DATE: MAY 16, 2016 REV: MAY 23, 2016 I off 508-362-4541 fax 508-362-9880 downcope.com down cn�e engineering, inc. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 16-123