HomeMy WebLinkAboutEngineered Plan - 20160 ACCESS COVERS MUST BE WITHIN 6" OF FINISH GRADE \FIRST 2' TO BE LEVEL -7 9" MINIMUM. 3' MAXIMUM COVER MIN 2" OF PEASTONE OR F l L TER FABRIC -� 3/4" - 1 1/2' DIA. T 102. I l0/.4 ' 2 �o DOUBLE WASHED STONE c GAS 101.57 /0/.J 99.3 BAFFLE 3 OUTLET 2-500 GAL LEACHING CHAMBERS EXISTING D -BOX W14' STONE AROUND. I2.8'w x 25'1 x 2'd 1000 GAL H-20 SEPTIC TANK 6" CRUSHED STONE OR COMPACTED BASE PROFILE : NOT TO SCALE + /013.0 LOCUS MAP +103.2 INVERT EL E VA T I DNS : INVERT OUT SEPTIC TANK: 102.1 INVERT IN DIST. BOX: 101.57 INVERT OUT DIST. BOX: 101.4 INVERT IN LEACH CHAMBER: 101.3 BO T TOM OF LEACH CHAMBER: 99.3 ADJUSTED GROUND WATER: N/A OBSERVED GROUND WATER: N/A BOTTOM OF TEST HOLE # / : 94.3 SMB E'gj ACK L 0 /0 20 40 TRAI L LEGEND 0 CB -*103.9_ 104.0 WATER L I NE O SHED , - \+ GAS LINE OHW- OVER HEAD WIRES N 88°5-rI LIGHT POST --E- UNDERGROUND ELECTRIC LINE -T- 100.8 _ - 2-500 GALLON UNDERGROUND CABLEVISION LINE -I- 40.4 SPOT ELEVATION _---40 ....... - " I LEACHING CHAMBERS ) PROPOSED CONTOUR 10' LEACH I W/4• STONE AROUNDI l 8. EXISTING LEACH PIT TO BE PUMPED DRY AND B/ F- � • TPS/• _ . • •.•.•.• + , , I 103.6 10 . B IOYR D -BOX , \' 104.0 T SAND5/6 .• .... .•.......... 26------------------ I ----- 102.1 25' \ MEDIUM IOYR INSPECT AND REPLACE INLET TEE IF REQUIRED. oX IST I NG 104.5 + 104.6 1 ` �PTIC TANK I `V \ BRICK PATIO BM. CORNER STEP ' \ £L -lOS. 24 1 104.8, ) o � \- Z \ BATH KITCHEN w , W p \ \ BEDROOM BATH O0 LIVING ko BEDROOM ROOM v BEDROOM n / v , \ -- %0.841± S.F. _-- IP FND 00. 00 -100-- 1, SMB E'gj ACK L 0 /0 20 40 TRAI L LEGEND 0 CB CONCRETE BOUND -W WATER L I NE O HYDRANT G GAS LINE OHW- OVER HEAD WIRES 4- LIGHT POST --E- UNDERGROUND ELECTRIC LINE -T- UNDERGROUND TELEPHONE .LINE - CTV- UNDERGROUND CABLEVISION LINE -I- 40.4 SPOT ELEVATION _---40 ....... EXISTING CONTOUR 40 PROPOSED CONTOUR DESIGN CRITERIA: DESIGN FLOW: 3 BEDROOMS AT 1/0 G. P.D. PER BEDROOM EQUALS 330 G.P.D. NO GARBAGE GRINDER SEPTIC TANK REQUIRED: 330 G.P.D. X 200Y.- 660 GAL. SEPTIC TANK PROVIDED: 1000 GAL. EXISTING SOIL ABSORPTION SYSTEM REQUIRED: DESIGN PERC RATE C 5 MIN/INCH SOIL TEXTURAL CLASS - I EFFL DENT L OAD I NG RA TE - 0. 74 GPD/SF 330 GPD / 0.74 GPD/SF - 446 S.F. REQUIRED PROVIDED: 2-500 GAL LEACHING CHAMBERS W/4' STONE AROUND. A-47/ S.F. 471 S. F. x 0.74 - 348 G. P. D. GENERAL NO TES : I. THIS PLAN IS FOR THE DESIGN AND CONSTRUCTION OF THE SEWAGE DISPOSAL SYSTEM ONLY. 2. VERTICAL DATUM ISASSUMED. FOR BENCH MARKS SET. SEE SITE PLAN. J. ALL CONSTRUCTION METHODS AND MA TER I AL S AND MAINTENANCE OF THE SEPTIC SYSTEM SHALL CONFORM TO MASS. D.E.P. TITLE 5 AND LOCAL BOARD OF HEALTH REGULAT l ONS . 4. ALL SEPTIC SYSTEM COMPONENTS LOCATED UNDER AREAS SUBJECT TO VEHICULAR TRAFFIC OR GREATER THAN 3 ' IN DEPTH SHALL BE CAPABLE OF WI TH- STANDING H-20 WHEEL LOADS. 5. ALL SEWER PIPE SHALL BE SCHEDULE 40 PVC OR APPROVED EQUAL. 6. SEPTIC TANK AND D -BOX SHALL BE REINFORCED SOIL TEST PIT DA TA ® PRECAST CONCRETE OR APPROVED POLYETHYLENE. INDICATES INDICATES BOTH SHALL BE WATERTIGHT, D -BOX SHALL BE WATER PERCOLATION = OBSERVED TESTED FOR LEVEL WHEN THERE IS MORE THAN ONE TEST = GROUNDWATER OUTLET. 40" l20" NO WATER 94.3 DATE: APRIL 20. 2016 TEST BY: STEPHEN HAAS WITNESSED BY: AMY VONHONE PERC RATE: ( 2 MIN/INCH Yarmouth �(j�Health Department VED �laflne Date P kt:tjk, �SNOFMgS 0 .. S9C TERRY yGs o AN 7 " WARNER No. 38721 ' SE°' SEPT 1 C SYS TEM DESIGN SS L UMBER.JACK TRA / L , MAP 74 . PARCEL 00 WEST YARMOUTH. MA. PREPARED FOR : RA)=A EL B O T TE NE SCALE : TP #/ 20 ' 7. BEFORE CONSTRUCTION CALL 'DIG -SAFE". HORIZON TEXTURE COLOR 1 -888 -DIG -SAFE AND THE LOCAL WATER DEPT. 0" HAAS /04.3 FOR LOCATION OF UNDERGROUND UTILITIES. INC A LOAMY IOYR ( 508 SAND 2/2 8. EXISTING LEACH PIT TO BE PUMPED DRY AND 9". -------LOAMY 103.6 B IOYR BACKFILLED. SAND5/6 26------------------ I ----- 102.1 9. EXISTING SEPTIC TANK TO BE PUMPED AND CLEANED. C / MEDIUM IOYR INSPECT AND REPLACE INLET TEE IF REQUIRED. SAND 6/8 40" l20" NO WATER 94.3 DATE: APRIL 20. 2016 TEST BY: STEPHEN HAAS WITNESSED BY: AMY VONHONE PERC RATE: ( 2 MIN/INCH Yarmouth �(j�Health Department VED �laflne Date P kt:tjk, �SNOFMgS 0 .. S9C TERRY yGs o AN 7 " WARNER No. 38721 ' SE°' SEPT 1 C SYS TEM DESIGN SS L UMBER.JACK TRA / L , MAP 74 . PARCEL 00 WEST YARMOUTH. MA. PREPARED FOR : RA)=A EL B O T TE NE SCALE : / " - 20 ' APR / L 20, 2015 STEPHEN A. HAAS ENGINEERING, INC South Denn i P. O. B o x 16 s MA 02660 ( 508 ) Z62 -81Z2 IG JOB NO: 16-019