Loading...
HomeMy WebLinkAboutEngineered Plan - 2016LOCATION MAP LOT 44 (13,300 SF) ASSESSORS MAP: 91 PARCEL: 101 PLAN BOOK: 223, PAGE: 153 N 0) N ti N Q\ ` (A \ o� ro \ 1 \ \ O 2 /- \ � I \ t / t / PAVED DRIVE rn ry I? y a '0i__� FT -I\ o cr -W �A �� \ Q Gam„ \ N ` Q\ 2 \ X.3 � \ \ 4- 10100 M16-18i.p. LEACHING AREA: USE 2 - 500 GALLON CHAMBERS (8.5'x 4.8'x 2' EFF. DEPTH) WITH 4' OF STONE ALL AROUND (25' x 12.8' x 2' DEEP) SIDE AREA: (25' + 12.8') x 2 x 2 = 151 SF (0.74) =_L12 GAUDAY BOTTOM AREA: 25'x 12.8'= 320 SF (0.74) = 237 GAUDAY CAPACITY = 349 GAUDAY A p GE EX\ST ROOM O pEna,N1,0A •44 9 LOCUS Lu DINING ROOM SEPTIC SYSTEM DESIGN /I m / 2. SECTION 15.211 (1): SEPTIC TANK TO BE LESS THAN 10' FROM LOT LINE (VARIANCE OF 2'). 4. ALL PRECAST UNITS SUBJECT TO TRAFFIC LOADS TO CONFORM WITH AASHTO H-20 SPECIFICATIONS. w\ GU��E FLOW ESTIMATE: 7. THE SEPTIC SYSTEM HAS NOT BEEN DESIGNED TO ACCOMODATE THE USE OF A GARBAGE DISPOSAL. 8. ALL CONSTRUCTION DETAILS ARE TO BE IN CONFORMANCE WITH THE STATE OF MASS. ENVIRONMENTAL NCO 3 BEDROOMS AT 110 GAL / DAY = 330 GAL / DAY 9. CONTRACTOR TO VERIFY LOCATIONS OF ALL UTILITIES PRIOR TO CONSTRUCTION. N __jz W O �O CORNER OF SLATE PORCH SEPTIC TANK: ELEVATION = 101.34 14. D -BOX TO BE WATER TESTED TO ENSURE LEVELNESS AND EQUAL FLOW. 330 GAL / DAY x 2 DAYS = 660 GAL N USE 1500 GALLON SEPTIC TANK LL w`KRD LOCATION MAP LOT 44 (13,300 SF) ASSESSORS MAP: 91 PARCEL: 101 PLAN BOOK: 223, PAGE: 153 N 0) N ti N Q\ ` (A \ o� ro \ 1 \ \ O 2 /- \ � I \ t / t / PAVED DRIVE rn ry I? y a '0i__� FT -I\ o cr -W �A �� \ Q Gam„ \ N ` Q\ 2 \ X.3 � \ \ 4- 10100 M16-18i.p. LEACHING AREA: USE 2 - 500 GALLON CHAMBERS (8.5'x 4.8'x 2' EFF. DEPTH) WITH 4' OF STONE ALL AROUND (25' x 12.8' x 2' DEEP) SIDE AREA: (25' + 12.8') x 2 x 2 = 151 SF (0.74) =_L12 GAUDAY BOTTOM AREA: 25'x 12.8'= 320 SF (0.74) = 237 GAUDAY CAPACITY = 349 GAUDAY A p GE EX\ST ROOM O pEna,N1,0A •44 9 FAMILY ROOM KITCHEN Lu DINING ROOM L /I m / 2. SECTION 15.211 (1): SEPTIC TANK TO BE LESS THAN 10' FROM LOT LINE (VARIANCE OF 2'). 4. ALL PRECAST UNITS SUBJECT TO TRAFFIC LOADS TO CONFORM WITH AASHTO H-20 SPECIFICATIONS. w\ i cP ) 7. THE SEPTIC SYSTEM HAS NOT BEEN DESIGNED TO ACCOMODATE THE USE OF A GARBAGE DISPOSAL. 8. ALL CONSTRUCTION DETAILS ARE TO BE IN CONFORMANCE WITH THE STATE OF MASS. ENVIRONMENTAL CODE (TITLE FIVE) AND LOCAL HEALTH REGULATIONS. 9. CONTRACTOR TO VERIFY LOCATIONS OF ALL UTILITIES PRIOR TO CONSTRUCTION. FAMILY ROOM SEPTIC SYSTEM SECTION TOP OF FOUNDATION BATH BATH ELEV. 1500 GAL SEPTIC TANK (6" OF STONE UNDER OR OF COMPACTED) TEE SIZES: INLET: 6" UP, 13" DOWN OUTLET: 6" UP, 14" DOWN T MAX. erft, COVER (V MIN) ELEV. 97 02 96.85 ELEV. D -BOX ELEV. ME(CHOUNDER OR COMPACTED) -GAS BAFFLE AT OUTLET TEE ELEV. TEST HOLE LOGS ENGINEER: THOMAS McLELLAN, P.E. WITNESS: AMY VON HONE, R.S. DATE: 5-26-16 BED PERCOLATION RATE: < 2 MIN/IN ROOM BED I BED ROOM ROOM NOTES: PEASTONE OR FILTER FABRIC 3/4" -1 1/2" WASHED STONE INSPECTION PORT ELEV.= 97.5 1, l 9 ° ° ° ° HM 94.67 H <--> ELEV. -25'x 12.8' 2 - 500 GALLON CHAMBERS WITH 4' OF STONE ALL AROUND (25'x 12.8'x 2' DEEP) TH-1 100.5 FILL ELEV. O/A HORIZON LOAMY SAND 10YR 4/1 99.0 B HORIZON LOAMY SAND 10YR 5/8 98.3 C HORIZON MEDIUM SAND PERC AT 48" 2.5Y 7/4 138"1 1 89.0 NO GROUND WATER ENCOUNTERED KITCHEN Lu DINING ROOM REQUIRED VARIANCES FROM TITLE FIVE: 3. SCHEDULE 40 - 4" PVC PIPE TO BE USED THROUGHOUT SEPTIC SYSTEM. Q 2. SECTION 15.211 (1): SEPTIC TANK TO BE LESS THAN 10' FROM LOT LINE (VARIANCE OF 2'). 4. ALL PRECAST UNITS SUBJECT TO TRAFFIC LOADS TO CONFORM WITH AASHTO H-20 SPECIFICATIONS. LIVING ROOM SEPTIC SYSTEM SECTION TOP OF FOUNDATION BATH BATH ELEV. 1500 GAL SEPTIC TANK (6" OF STONE UNDER OR OF COMPACTED) TEE SIZES: INLET: 6" UP, 13" DOWN OUTLET: 6" UP, 14" DOWN T MAX. erft, COVER (V MIN) ELEV. 97 02 96.85 ELEV. D -BOX ELEV. ME(CHOUNDER OR COMPACTED) -GAS BAFFLE AT OUTLET TEE ELEV. TEST HOLE LOGS ENGINEER: THOMAS McLELLAN, P.E. WITNESS: AMY VON HONE, R.S. DATE: 5-26-16 BED PERCOLATION RATE: < 2 MIN/IN ROOM BED I BED ROOM ROOM NOTES: PEASTONE OR FILTER FABRIC 3/4" -1 1/2" WASHED STONE INSPECTION PORT ELEV.= 97.5 1, l 9 ° ° ° ° HM 94.67 H <--> ELEV. -25'x 12.8' 2 - 500 GALLON CHAMBERS WITH 4' OF STONE ALL AROUND (25'x 12.8'x 2' DEEP) TH-1 100.5 FILL ELEV. O/A HORIZON LOAMY SAND 10YR 4/1 99.0 B HORIZON LOAMY SAND 10YR 5/8 98.3 C HORIZON MEDIUM SAND PERC AT 48" 2.5Y 7/4 138"1 1 89.0 NO GROUND WATER ENCOUNTERED Permit valid for Rt'.I'A11t OF SI,:PTIC SYSTEM ONLY, d'ue to State and I "cal septic variances. Board oflicalth review and aliprnvaI is required for any, tulure +dilitinns/revocations/alterations to sewage facilities and/or struetures/dwwelling. a etre Yarmouth Health Department APPROVED/SP S Date' EXISTING FLOOR PLAN 1. VERTICAL DATUM: ASSUMED 2. MUNICAPAL WATER IS AVAILABLE. EXISTING CONTOUR: - - - - REQUIRED VARIANCES FROM TITLE FIVE: 3. SCHEDULE 40 - 4" PVC PIPE TO BE USED THROUGHOUT SEPTIC SYSTEM. 1. SECTION 15.211 (1): LEACH AREA TO BE LESS THAN 10' FROM LOT.LINE_(VARIANCE OF 2'). 2. SECTION 15.211 (1): SEPTIC TANK TO BE LESS THAN 10' FROM LOT LINE (VARIANCE OF 2'). 4. ALL PRECAST UNITS SUBJECT TO TRAFFIC LOADS TO CONFORM WITH AASHTO H-20 SPECIFICATIONS. 5. PIPE PITCH = 1/8" & 1/4" PER FOOT (UNLESS NOTED OTHERWISE). 6. FIRST 2' OF PIPE OUT OF D -BOX TO BE SET LEVEL. 7. THE SEPTIC SYSTEM HAS NOT BEEN DESIGNED TO ACCOMODATE THE USE OF A GARBAGE DISPOSAL. 8. ALL CONSTRUCTION DETAILS ARE TO BE IN CONFORMANCE WITH THE STATE OF MASS. ENVIRONMENTAL CODE (TITLE FIVE) AND LOCAL HEALTH REGULATIONS. 9. CONTRACTOR TO VERIFY LOCATIONS OF ALL UTILITIES PRIOR TO CONSTRUCTION. 10. GROUND COVER OVER ALL SEPTIC SYSTEM COMPONENTS NOT TO EXCEED 31. 11. FIELD SURVEY PROVIDED BY TERRY A. WARNER, P.L.S., HARWICH, MA. BENCHMARK AT 12. THIS PLAN REQUIRES THE REVIEW AND APPROVAL OF ONE OR MORE TOWN DEPARTMENTS AND IS SUBJECT TO CHANGE UNTIL SUCH TIME. CORNER OF SLATE PORCH 13. EXISTING CESS POOL IS TO BE PUMPED AND FILLED WITH SAND OR REMOVED. ELEVATION = 101.34 14. D -BOX TO BE WATER TESTED TO ENSURE LEVELNESS AND EQUAL FLOW. Permit valid for Rt'.I'A11t OF SI,:PTIC SYSTEM ONLY, d'ue to State and I "cal septic variances. Board oflicalth review and aliprnvaI is required for any, tulure +dilitinns/revocations/alterations to sewage facilities and/or struetures/dwwelling. a etre Yarmouth Health Department APPROVED/SP S Date' JUS! -I U 2016 HEALTH DEPT. SITE PLAN LOCATION: °A 22 OUT OF BOUNDS DR., S. YARMOUTH,MA PREPARED FOR: I r ANN MAHONEY g , x1 ,✓1' DATE: 6-3-16 SCALE: 1" = 20' BASS RIVER ENGINEERING THOMAS J. McL AN, P.E. P.O. BOX 1163, EAST DENNIS, MA 02641 508-364-9048 KEY: EXISTING CONTOUR: - - - - �l 100 PROPOSED CONTOUR: ............. EXISTING SPOT ELEVATION: 25.5 PROPOSED SPOT ELEVATION: 25.5 TEST HOLE: UTILITY POLE: -o- FENCE LINE: - HYDRANT: RETAINING WALL: JUS! -I U 2016 HEALTH DEPT. SITE PLAN LOCATION: °A 22 OUT OF BOUNDS DR., S. YARMOUTH,MA PREPARED FOR: I r ANN MAHONEY g , x1 ,✓1' DATE: 6-3-16 SCALE: 1" = 20' BASS RIVER ENGINEERING THOMAS J. McL AN, P.E. P.O. BOX 1163, EAST DENNIS, MA 02641 508-364-9048