Loading...
HomeMy WebLinkAboutEngineered Plan - 20163/4" TO 1 1/2" CLEAN$ (SAS) INDEX DOUBLE WASHED STONE ADJUST FREE OF FINES & SILT SEWAGE DISPOSAL SYSTEM. PROFILE OBSERVED"SGS WATERRTABBEE( wA/ R � BL) ELEV. = ------ NOT TO SCALE BOTTOM OF TEST HOLE ELEV. = 95.9 J 0 w LEGEND: EXISTING SPOT ELEVATION OO, 0 EXISTING CONTOUR----00---- FINAL SPOT ELEVATION 0� FINAL CONTOUR 00 SOIL TEST LOCATION UTILITY POLE -0- TOWN WATER =W- TOP OF FOUNDATION CATCH BASIN®� 20 FT. MINIMUM FROM CELLAR OR CRAWL SPACE GAS LINE ELEV. = 100-00_ 10 FT. MINIMUM 10 FT. MINIMUM FROM SLAB s M77 UUM7 RUIG 203 SETUCKET ROAD P. 0. BOX 713 38 -6900 SOUTH DENNIS, MASS. 02660 DATE APR. 27, 2016 SCALE 1 " = 20' CLEAN SAND (ASSUMED) CONCRETE REV. COVERS INSPECTION PORT LOCATION MAP REV. SHEET 1 OF 1 4" SCHEDULE 40 PVC PIPE LOAM AND SEED MIN. PITCH 1/8" PER FT. 2" LAYER OF 1/8" TO 1/2" WASHED STONE . 2.5f 4" CAST IRON PIPE 6„ MAX. 6 AX 6 M 00.21 MAX. OR FILTER FABRIC 98.98 MIN. VENT (OR EQUAL) MINIMUM 98.58 NOT REQUIRED PITCH `1 /4" PER FT. FLOW TEE Z LEVELERS FLOW LINE 97.21 ELEV. _ _97.5f - - 10" TMIN. 0 0 0 r ELEV. = 97.17 EVE _ - LEVEL o _ 10. 0 ELEV. _ 97.00_ - ADD GAS ELEV. _ 6" SUMP 96_8 ELEV. _ _ 95.71 _ o _ _ _ -_ o ELEV. _ _95.88_ BAFFLE _ DISTRIBUTION LIQUID OUTLET ELEV. _ p®v BOX 4 HIGH CAPACITY INFILTRATORS WITH STONE IN (EXISTING) --95+I1- AN 5 FEET 14 INCHES 1000 GALLON TO BE WATER TESTED IF MORE THAN ONE OUTLET 11' X 36' X 10" TRENCH FORMATION .88 6 FEET 8 FEET 24 INCHES 34 INCHES SEPTIC TANS (TO BE PLACED ON FIRM BASE) ® Un SOIL ABSORPTION ZWELL ONE N/A 3/4" TO 1 1/2" CLEAN$ (SAS) INDEX DOUBLE WASHED STONE ADJUST FREE OF FINES & SILT SEWAGE DISPOSAL SYSTEM. PROFILE OBSERVED"SGS WATERRTABBEE( wA/ R � BL) ELEV. = ------ NOT TO SCALE BOTTOM OF TEST HOLE ELEV. = 95.9 J 0 w LEGEND: EXISTING SPOT ELEVATION OO, 0 EXISTING CONTOUR----00---- FINAL SPOT ELEVATION 0� FINAL CONTOUR 00 SOIL TEST LOCATION UTILITY POLE -0- TOWN WATER =W- W CATCH BASIN®� 6-16" GAS LINE CLEAN OUT C 0 CESSPOOL C.P. Q o- SOIL TEST DATE OF SOIL TEST APRIL_27 2016 "------ SOIL TEST DONE BY SWEETSER ENGINEERING WITNESSED BY .�:VOr0�IE���__ OBSERVATION HOLE 1 ELEV.=_-100:0 PERCOLATION RATE<,2 _ MIN./INCH .AT 38 INCHES DEPTH HORIZ TEXTURE COLOR MOTT. OTHER 0-6" Ap LOAMY SAND 10YR4/1 NO ROOTS 6-16" B___ LOAMY SAND 10YR7/6 ROOTS 16-144" C MEDIUM SAND 2.5Y7/4 NO WATER ENCOUNTERED AT __144,. ELEV. _ _ 88.0 DESIGN CALCULATIONS NUMBER OF BEDROOMS _ 3 GARBAGE DISPOSAL UNIT _ NO _ TOTAL ESTIMATED FLOW ( 110 GAL/C-R./DAY X 3 RR.) _33Q_ GAL./DAY REQUIRED SEPTIC TANK CAPACITY __6M_ GAL. ACTUAL SIZE OF SEPTIC TANK (DQSTING) _1000 GAL. SOIL CLASSIFICATION DESIGN PERCOLATION RATE <_5MIN./IN. EFFLUENT LOADING RATE Q.7-4_ GAL./DAY/S.F. LEACHING AREA 474.33 SQ. FT. (11X36)+(47X2X10/12) LEACHING CAPACITY (AREA X RATE) -35tQQ GAL./DAY 474.33 X 0.74 RESERVE LEACHING CAPACITY .flON-EL GAL./DAY NOTES: 1. ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO D.E.P. TITLE 5 AND THE TOWN'S RULES AND REGULATIONS FOR THE SUBSURFACE DISPOSAL OF SEWAGE. 2. ALL COVERS TO SANITARY UNITS SHALL BE BROUGHT TO WITHIN 6" OF FINISHED GRADE. 3. ALL COMPONENTS OF THE SANITARY SYSTEM SHALL BE CAPABLE OF WITHSTANDING H-10 LOADING UNLESS THEY ARE UNDER OR WITHIN 10 FT. OF DRIVES OR PARKING AREAS, H-20 LOVING SHALL BE USED UNDER OR WITHIN 10 FT, OF DRIVES OR PARKING AREAS. 4. ANY MASONARY UNITS USED TO BRING COVERS TO GRADE SHALL BE MORTARED IN PLACE. 5. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEEDED OR ZONING REGULATIONS. OWNER / APPLICANT IS TO OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY. 6. UTILITIES SHOWN ARE APPROXIMATE ONLY, EXCAVATION CONTRACTOR IS TO CALL "DIG -SAFE" AT 1-888-344-7233 AT LEAST 72 HOURS PRIOR TO COMMENCING WORK ON SITE. 7. CONTRACTOR IS TO VERIFY GRADES AND ELEVATIONS AS WELL AS SITE CONDITIONS PRIOR TO COMMENCING WORK ON SITE. ANY VARIATION IS TO BE BROUGHT TO THE ATTENTION OF THE DESIGN ENGINEER IMMEDIATELY. 8. PARCEL IS IN FLOOD ZONE x____. 9. LOT IS SHOWN ON ASSESSORS MAP _ 13_2__ AS PARCEL _ 107 _. 10. ONE OF THE EXISTING LEACH PITS (P&P.), IS TO BE PUMPED AND REMOVED ALONG WITH ANY POLLUTED SOILS ENCOUNTERED, THE OTHER PIT IS TO BE PUMPED AND BACKFILLED (P&B). Yhrmouth Hedth Departmemt APMPVED., l�dnme Date APPROV. ED: BOARD, HEALTH DATE AGENT C.• �S8�PRO,1 7690-00�dwg`7690-SAS.DWG 02016 SWEETSER ENGINEERING Y ',' OUTH, Loc v ROUTE- 6,q MASS. eE` �FOE�F o ESSEX � o IZD =- z z PROPOSED SEPTIC DESIGN FOR ROBERT SANBORN LQC.n CA - DO i" 111`01A LOT 26 :OUT , MSS. s M77 UUM7 RUIG 203 SETUCKET ROAD P. 0. BOX 713 38 -6900 SOUTH DENNIS, MASS. 02660 DATE APR. 27, 2016 SCALE 1 " = 20' JOB NO. 7690-00 REV. LOCATION MAP REV. SHEET 1 OF 1 C.• �S8�PRO,1 7690-00�dwg`7690-SAS.DWG 02016 SWEETSER ENGINEERING