Loading...
HomeMy WebLinkAboutEngineered Plan - 2016LEGEND ay — EXISTING CONTOUR X 99. EXIST. SPOT ELEV. —[99]— PROPOSED CONTOUR [98.4] PROPOSED SPOT EL. TH1 Q TEST HOLE 2YYYi SLOPE OF GROUND C -Q) UTILITY POLE FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING PROP. VENT WITH CHARCOAL FILTER AND BUGSCREEN (FINAL PLACEMENT BY CONTRACTOR WITH HOMEOWNER CONSULTATION) A DCE #16-116 SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED r DESIGN FLOW: 4 BEDROOMS @ 110 GPD = 440 GPD USE A 440 GPD DESIGN FLOW SEPTIC TANK: 440 GPD (2) = 880 USE EXISTING 1000 GAL. SEPTIC TANK** LEACHING: SIDES: �2 (33.5 + 12.8) 2 (.74) = 137 GPD BOTTOM 33.5 x 12.8 (.74) = 317 GPD TOTAL: 614 S. F. 454 GPD USE (3) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH 4' STONE ALL AROUND \ �2 ACCESS COVERS TO WITHIN 6" OF FIN. GRADE OF I I i i SYSTEM PROFILE (NOT TO SCALE) !I 2" PEASTONE OR GEOTEXTILE FILTER FABRIC OVER STONE ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. CONCRETE COVERS TO WITHIN 3" GRADE 2% SLOPE REQUIRED OVER SYSTEM PRECAST w30 WATERTE�T D'BOX FOR LEVELNESS BLOCKS OR RISE (nP.) 71 3' MIN. 2 CKNESS PRECAST RISERS 4"OSCH40 PVC MORTAR ALL INVERT IN 69.0' „. PIPES LEVEL 1ST 2' I_ 4' COMPONENTS (NP') E 4' NDS SIDES 7 10" EXISTING 14" o.•, TEE SEPTIC TANK** TEE 69.9 GAS BAFFLE 0°°°000° ®�®®® Io°o°o<o°o0°o°0o°°0og°° °o°o°o° °0°00000o°0° 0°0 0p00°°o2ER °0°o°0°69.27 69. °°°O°0 00° EP FER1 t 3/4"-1-1/2" DOUBLE WASHED STONE 4' MIN. H-20 500 GAL. LEACHING CHAMBERS BY ACME PRECAST OR EQI ALL AROUNDPRECAST STRUCTURES (3) UNITS REQUIRED 6" CRUSHED STONE OR MECHANICAL OVERALL DIMENSIONS TO OUTSIDE OF STONE: 33.5' X 12.83' COMPACTION. (15.221 [2]) I (11% SLOPE) I ( 1 % SLOPE) FOUNDATION— EXIST. SEPTIC TANK 57' D' BOX LEACHING 61.0' BOTTOM _ 12 FACILITY NO GROUNDWATER FOUND *THE INSTALLER SHALL VERIFY THE **INSTALLER SHALL CONFIRM MINIMUM LOCATIONS OF ALL UTILITIES AND ALL SEPTIC TANK SIZE AT 1000 GALLONS BUILDING SEWER OUTLETS AND AND ITS SUITABILITY FOR RE -USE. ELEVATIONS PRIOR TO INSTALLING ANY REPLACE WITH 1500 GALLON SEPTIC PORTION OF SEPTIC SYSTEM TANK APPROPRIATE TO SITE CONDITIONS IF NOT SUITABLE I ___ . ___ - F 72 �111Ojq O -26 A,26 �.s9. R,84 0.08, \ VENT KEEPING LIVING F< GARAGE LAUNDR KITCHEN DINING BATH $EDFIG01( BEDROOM V) BEDROOM BATH BEDROOM 2ND FLOOR PLAN NOT TO SCALE 1ST FLOOR PLAN NOT TO SCALE rn UNFINISHED FAMILY BATH BASEMENT FLOOR PLAN NOT TO SCALE NOTES 1. DATUM IS A55UIVIEU 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H -2Q 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. DATE DANIEL A. OJALA, P.E., P.L.S. LOCUS MAP NOT TO SCALE ASSESSORS MAP 143 PARCEL 130 TEST HOLE LOGS ENGINEER: CRAIG J. FERRARI, SE ##13871 WITNESS: AMY VON HONE, RS (YARMOUTH) DATE: 4/20/16 PERC. RATE _ < 2 MIN/INCH CLASS 1 SOILS ELEV. 0" 1 72.0' A LS 1OYR 2/2 12" B LS 30" 1OYR 5/8 69.5' PERC C MS Yarmouth Health Department Pp 'a V D 1OYR 7/4 a�1ne Bate o_- 132" 61.0' NO GROUNDWATER ENCOUNTERED 99 SETUCKET ROAD YARMOUTH PORT. MA PREPARED FOR MR. & MRS. TUCKER DATE: MAY 9, 2016 Scale:1 "= 20' 0 10 20 30 40 50 FEET off 508-362-4541 I fax 508-362-9880 downcape.com 170WI) cape en�ineefin f, into. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 16-116 TUCKER.DWG Low fe Q 111010n/ setucket Po oa 0 Locus eco �a• c� 0 Mill Follins Pond Pond LOCUS MAP NOT TO SCALE ASSESSORS MAP 143 PARCEL 130 TEST HOLE LOGS ENGINEER: CRAIG J. FERRARI, SE ##13871 WITNESS: AMY VON HONE, RS (YARMOUTH) DATE: 4/20/16 PERC. RATE _ < 2 MIN/INCH CLASS 1 SOILS ELEV. 0" 1 72.0' A LS 1OYR 2/2 12" B LS 30" 1OYR 5/8 69.5' PERC C MS Yarmouth Health Department Pp 'a V D 1OYR 7/4 a�1ne Bate o_- 132" 61.0' NO GROUNDWATER ENCOUNTERED 99 SETUCKET ROAD YARMOUTH PORT. MA PREPARED FOR MR. & MRS. TUCKER DATE: MAY 9, 2016 Scale:1 "= 20' 0 10 20 30 40 50 FEET off 508-362-4541 I fax 508-362-9880 downcape.com 170WI) cape en�ineefin f, into. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 16-116 TUCKER.DWG