Loading...
HomeMy WebLinkAboutEngineered Plan - 2016SYSTEM PROFILE (NOT TO SCALE) ACCESS COVERS TO WITHIN 6" OF FIN. GRADE 22.8' MINIMUM .754 OF 1 PRECAST H-10 RISERS (iYP.) 2'b *U 10" 1500 GAL H-10 14" 19.77 TEE SEPTIC TANK TEE GAS BAF +: 4' UQ. LEVEL (ACME OR EQU PRECAST 4'OSCH40 PVC PIPES LEVEL 1 ST 2 19.52' ° 3000° °0 00 °00°° 19.48' 0i 1' WATER -TEST D'BOX FOR LEVELNESS 6" CRUSHED STONE OR MECHANICAL COMPACTION. (15.221 [21) ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. PROVIDE INSPECTION PORTS TO WITHIN 3" OF FINISH GRADE 2% SLOPE REQUIRED OVER SYSTEM Z J, (_3_% SLOPE) (-!-% SLOPE) FOUNDATION- 27' SEPTIC TANK 6' - *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM LEGEND 99- EXISTING CONTOUR X 99 1 EXIST. SPOT ELEV. 99 PROPOSED CONTOUR PROPOSED SPOT EL. TH1 G.W. FROM 5' TO 4.0' TEST HOLE 2� SLOPE OF GROUND ADJUSTMENT TO UTILITY POLE INSTALLATION. FIRE HYDRANT NOTE NOT ALL SYMBOLS MAY APPEAR IN DRAWING TEST HOLE LOGS ENGINEER: CRAIG J. FERRARI, SE #13871 WITNESS: PHIL RENAUD (BoH) DATE: 6/20/14 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS Q ELEV. 1 Ott 22.0' A LS 10" 1OYR 4/3 B LS 249) 1OYR 6/8 20.0' `! PERC MS 1OYR 7/4 120" 12.0' GROUNDWATER A[ WELL: MIW 29 ZONE: A ADJUSTMENT: 1.0 (APRIL) GROUNDWATER ENCOUNTERED @ 90" EL. 14.5 DICE #16-132 QUICK4 STANDARD LOW PROFILE UNITS OVERALL DIMENSIONS TO OUTSIDE OF UNITS: 24' X 11.3' (NO STONE PROPOSED) (-1-7. SLOPE) 5' LEACHING FACILITY 4.0' ADJUSTED GROUNDWATER EL. 15.0 G -W ADJ. DATA: WELL: MIW-29 ZONE: A ADJ: 1.0' USE 0.5 ADJUSTMENT NOTES 1. DATUM IS ASSUMED 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-10 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND.FILLED WITH CLEAN SAND. VARIANCES REQUESTED: UNDER MAXIMUM FEASIBLE COMPLIANCE - LOCAL UPGRADE APPROVAL 310 CMR 15.405(1)(h): REDUCTION IN SEPARATION OF SAS TO ADJ. G.W. FROM 5' TO 4.0' YARMOUTH HEALTH DEPT. POLICY: REQUEST USING HALF THE ADJUSTMENT TO PREVENT PUMP CHAMBER INSTALLATION. FLOOR PLAN NOT TO SCALE Pcrnlit'Vail d for RFPAIR OF SEV1.1(: "' SN'S,n� [ONLY, d' lie to State anti t.ocal septic Variances. Board of health review and apil-gal is required for futinre additions/renovations alterations to sewage facilities and/, structures/dwelling• Yarmotitth film,11 ) I))/ep(�}ar■$nnent { CJ� e I)ate LOCUS MAP NOT TO SCALE ASSESSORS MAP 24 PARCEL 99 SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 3 BEDROOMS @ 110 GPD = 110 GPD USE A 330 GPD DESIGN FLOW SEPTIC TANK: 330 GPD (2) = 660 USE A 1500 GAL. SEPTIC TANK LEACHING: 4.72 SF/LF x 4' LENGTH = 18.88 SF PER QUICK4 PLUS STANDARD LP UNIT 330 GPD/0.74 GPD/SF = 446 SF LEACHING REQ'D 446 SF/18.88 SF/UNIT = 23.6 UNITS THEREFORE, USE GRAVELLESS SYSTEM OF` (24) QUICK4 STANDARD LP UNITS IN FIELD CONFIGURATION OF 4 ROWS OF 6 UNITS 24 UNITS x 18.88 SF/UNIT = 453 SF> 446 SF 453 SF (0.74) = 335 GPD (OK) APPROVED DATE BOARD OF HEALTH TITLE 5 SITE PLAN OF 43 PAMET ROAD WEST YARMOUTH, MA (Yv� PREPARED FOR DIANE MONTGOMERY Scale:1 "= 20' 0 10 20 30 40 50 FEET DATE DANIEL A. OJALA, P.E., P.L.S. DATE: MAY 9, 2016 off 508-362-4541 I fax 508-362-9880 downcape.com IT0W#7 cafe iaeerinf, iac. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 , MA