HomeMy WebLinkAboutReview Checklist � '
� /~/�" TOWN OF YARMOUTH `-���
7 3
• SEWAGE PLAN REVIEW CHECKLIST � , - `) �''�-v'T= �
���,�
Location: A.M.� Lot �� � Zone of Contribution: In �ut y'_ Acreage����
` Commercial:_.__�,T_'"�,Residential: �
Street: � S' � ' ��
Village: � Floor Pl : #Bedrooms: S� �������
. ����
o.��: /' �S�ll�:
� �
Address: Phone: '
Phone:
Builder: �� Engineer:
Address: Phone: � �-6 -
Phone: j�' f
,�`" � �t'� i Lr '-;°�? �yr Z��,j
N/A YES O
1.Required#of copies received
2.Date of soils exam and percolation test not older than 2 years c_
3.4-5 ft of naturall occurrin ervious material, above water table ��
4.Foundation 2 ft above high oint of road H.P.: Fnd: Var.: ._�
5.Water line 10 ft from s tic com onents Var.:
6.Benchmark indicated and shown-NGVD if near wetlands t---'�
7. S tic tank minimum 10 ft from foundadon, deck Vax.: -'""
8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.:
9.Leaching minimum 100 ft from wetlands Var.:
10.Leaching minimum 150 ft from drinking welU25 ft irri tion well Var.: ---"-�
11.Tank/leaching minimum 10 ft from ro erty line Var.:
12. S stem meets all other setback r uirements Var.: ✓
13.Uses ad'ustment for maximum hi oundwater Var.:
14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.:
15. System not in top or subsoil(A,B horizons)or 5'removal �,/
16.Pro osed contours are suitable
17. S stem meets slo e r uirements-min. 1/8", '/4" referted �-�''"
18. System meets breakout r uirements PVC liner: Wall:
19. S ecified tee sizes are pro er, as baffle on outlet tee .�_.-�''
20. Sewage is under 10,000 d for arcel �,.,/
21.No arbage disposal
� 22.S stem ade uatel sized for its intended use
23.Minimum 6"stone or com acted below tank and dbox ��,
24.Manhole covers within 6"of ade, um chamber cover to ade
� 25.Ins ection port on lastic chambers/leach field Li
26.Electrical ermit for um chamber/S a,rate meter for du lexes
27.Pum stem-2" line,wee hole,check valve,tee in dbox, ump size
28. S tic tank/ um chamber to be factory wat roofed �`�"
29.Vent rovided if leaching below 3 feet,under driveway/parkin --�'""��
30.Buoyancy calculations for tank/pum chamber
31.En ' eer to ins ect and cert' soils: wall: commercial:
32.En ' eer/Re ' tered Sanitarian and I,and Surveyor stam s/signature -
33.H-20 loading is subject to vehicular traffic, groundwater _.�'
34.Title V A lication and ermit fee, insta.11er si ture `i
35.Founda.tion footing min. 2 feet above ad'usted ground water for new house ..._.�"
36.Deed Restriction r ired max. #bedrooms: max. flow: d
37.Check area lots for groundwater/Label groundwater in Assessor's Ma "
Plan reviewed by: � L�,��r wosio3