Loading...
HomeMy WebLinkAboutReview Checklist � ' � /~/�" TOWN OF YARMOUTH `-��� 7 3 • SEWAGE PLAN REVIEW CHECKLIST � , - `) �''�-v'T= � ���,� Location: A.M.� Lot �� � Zone of Contribution: In �ut y'_ Acreage���� ` Commercial:_.__�,T_'"�,Residential: � Street: � S' � ' �� Village: � Floor Pl : #Bedrooms: S� ������� . ���� o.��: /' �S�ll�: � � Address: Phone: ' Phone: Builder: �� Engineer: Address: Phone: � �-6 - Phone: j�' f ,�`" � �t'� i Lr '-;°�? �yr Z��,j N/A YES O 1.Required#of copies received 2.Date of soils exam and percolation test not older than 2 years c_ 3.4-5 ft of naturall occurrin ervious material, above water table �� 4.Foundation 2 ft above high oint of road H.P.: Fnd: Var.: ._� 5.Water line 10 ft from s tic com onents Var.: 6.Benchmark indicated and shown-NGVD if near wetlands t---'� 7. S tic tank minimum 10 ft from foundadon, deck Vax.: -'"" 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: 9.Leaching minimum 100 ft from wetlands Var.: 10.Leaching minimum 150 ft from drinking welU25 ft irri tion well Var.: ---"-� 11.Tank/leaching minimum 10 ft from ro erty line Var.: 12. S stem meets all other setback r uirements Var.: ✓ 13.Uses ad'ustment for maximum hi oundwater Var.: 14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.: 15. System not in top or subsoil(A,B horizons)or 5'removal �,/ 16.Pro osed contours are suitable 17. S stem meets slo e r uirements-min. 1/8", '/4" referted �-�''" 18. System meets breakout r uirements PVC liner: Wall: 19. S ecified tee sizes are pro er, as baffle on outlet tee .�_.-�'' 20. Sewage is under 10,000 d for arcel �,.,/ 21.No arbage disposal � 22.S stem ade uatel sized for its intended use 23.Minimum 6"stone or com acted below tank and dbox ��, 24.Manhole covers within 6"of ade, um chamber cover to ade � 25.Ins ection port on lastic chambers/leach field Li 26.Electrical ermit for um chamber/S a,rate meter for du lexes 27.Pum stem-2" line,wee hole,check valve,tee in dbox, ump size 28. S tic tank/ um chamber to be factory wat roofed �`�" 29.Vent rovided if leaching below 3 feet,under driveway/parkin --�'""�� 30.Buoyancy calculations for tank/pum chamber 31.En ' eer to ins ect and cert' soils: wall: commercial: 32.En ' eer/Re ' tered Sanitarian and I,and Surveyor stam s/signature - 33.H-20 loading is subject to vehicular traffic, groundwater _.�' 34.Title V A lication and ermit fee, insta.11er si ture `i 35.Founda.tion footing min. 2 feet above ad'usted ground water for new house ..._.�" 36.Deed Restriction r ired max. #bedrooms: max. flow: d 37.Check area lots for groundwater/Label groundwater in Assessor's Ma " Plan reviewed by: � L�,��r wosio3