HomeMy WebLinkAboutEngineered Plan - Rev. 2016-WAY OLUSjI LOCATION MAP LOT 67 (10,887 SF) ASSESSORS MAP: 66 PARCEL: 47 PLAN BOOK: 258, PAGE: 5 pi M16-09 KEY: EXISTING CONTOUR: - - - - PROPOSED CONTOUR: ............. EXISTING SPOT ELEVATION: 25.5 PROPOSED SPOT ELEVATION: 25.5 TEST HOLE: + UTILITY POLE: -0- FENCE LINE: - HYDRANT:... RETAINING WALL: BENCHMARK AT RIGHT CORNER OF CONC. SHOWER PAD ELEVATION = 99.16 100. JtOck 1 12,E 1oak 101 01 100 99 i - ---101 SEPTIC SYSTEM DESIGN FLOW ESTIMATE: (3 BEDROOM LEACH AREA DESIGN, MINIMUM) 2 BEDROOMS AT 110 GAL / DAY = 220 GAL / DAY SEPTIC TANK: 220 GAL / DAY x 2 DAYS = 440 GAL USE 1000 GALLON SEPTIC TANK (EXISTING) LEACHING AREA: USE 2 - 500 GALLON CHAMBERS (8.5'x 4.8'x 2' EFF. DEPTH) WITH i 4' OF STONE ALL AROUND (25'x 12.8'x 2' DEEP) SIDE AREA: (25' + 12.8') x 2 x 2 = 151 SF (0.74) = 112 GAUDAY BOTTOM AREA: 25'x 12.8'= 320 SF (0.74) = 237 GAUDAY CAPACITY = 349 GAUDAY 97/ 95 SEPTIC SYSTEM SECTION FLOOR COVERS WITHIN 6" 99.52 OF FINISHED GRAC TOP OF lga�„�� .�f���s ; ° FOUNDATION my 1 , •- 97.35 ELEV. d FAMILY ROOM DECK GARAGE BENCHMARK AT MAG NAIL ELEVATION = 94.65 1 1000 GAL SEPTIC TANK TEE SIZES: (TO BE CONFIRMED) INLET: 6" UP, 13" DOWN OUTLET: 6" UP, 14" DOWN DINING KITCHEN AREA I BATH I BATH LIVINGI BED I BED ROOM ROOM ROOM porch EXISTING FLOOR PLAN 2" PEASTONE OR FILTER FABRIC - 3/4" - 1 1/2" WASHED STONE INSPECTION PORT ELEV.= 95.5 T MAX. COVER (1' MIN) ELEV. ELEV. Lal 1°°°°° ... °°°°I'IeJ 92.67 D -BOX (6" OF STONE UNDER OR 4 4 ELEV. MECHANICALLY COMPACTED) _25'x 12.8' 94.67 2 - 500 GALLON CHAMBERS WITH 4' OF STONE ALL AROUND ELEV. (25'x 12.8'x 2' DEEP) -GAS BAFFLE AT OUTLET TEE TEST HOLE LOGS ENGINEER: THOMAS McLELLAN, RE WITNESS: AMY VON HONE, R.S. DATE: 4-14-16 PERCOLATION RATE: < 2 MIN/IN NOTES: TH-1 98.0 n ELEV. 'IT 97.0 jWHITTIE4R DDLACE LOAMY SAND 18" 10YR 3/3 96.5 B HORIZON LOAMY SAND 36" 10YR 5/8 95.0 0 � LL OLUSjI LOCATION MAP LOT 67 (10,887 SF) ASSESSORS MAP: 66 PARCEL: 47 PLAN BOOK: 258, PAGE: 5 pi M16-09 KEY: EXISTING CONTOUR: - - - - PROPOSED CONTOUR: ............. EXISTING SPOT ELEVATION: 25.5 PROPOSED SPOT ELEVATION: 25.5 TEST HOLE: + UTILITY POLE: -0- FENCE LINE: - HYDRANT:... RETAINING WALL: BENCHMARK AT RIGHT CORNER OF CONC. SHOWER PAD ELEVATION = 99.16 100. JtOck 1 12,E 1oak 101 01 100 99 i - ---101 SEPTIC SYSTEM DESIGN FLOW ESTIMATE: (3 BEDROOM LEACH AREA DESIGN, MINIMUM) 2 BEDROOMS AT 110 GAL / DAY = 220 GAL / DAY SEPTIC TANK: 220 GAL / DAY x 2 DAYS = 440 GAL USE 1000 GALLON SEPTIC TANK (EXISTING) LEACHING AREA: USE 2 - 500 GALLON CHAMBERS (8.5'x 4.8'x 2' EFF. DEPTH) WITH i 4' OF STONE ALL AROUND (25'x 12.8'x 2' DEEP) SIDE AREA: (25' + 12.8') x 2 x 2 = 151 SF (0.74) = 112 GAUDAY BOTTOM AREA: 25'x 12.8'= 320 SF (0.74) = 237 GAUDAY CAPACITY = 349 GAUDAY 97/ 95 SEPTIC SYSTEM SECTION FLOOR COVERS WITHIN 6" 99.52 OF FINISHED GRAC TOP OF lga�„�� .�f���s ; ° FOUNDATION my 1 , •- 97.35 ELEV. d FAMILY ROOM DECK GARAGE BENCHMARK AT MAG NAIL ELEVATION = 94.65 1 1000 GAL SEPTIC TANK TEE SIZES: (TO BE CONFIRMED) INLET: 6" UP, 13" DOWN OUTLET: 6" UP, 14" DOWN DINING KITCHEN AREA I BATH I BATH LIVINGI BED I BED ROOM ROOM ROOM porch EXISTING FLOOR PLAN 2" PEASTONE OR FILTER FABRIC - 3/4" - 1 1/2" WASHED STONE INSPECTION PORT ELEV.= 95.5 T MAX. COVER (1' MIN) ELEV. ELEV. Lal 1°°°°° ... °°°°I'IeJ 92.67 D -BOX (6" OF STONE UNDER OR 4 4 ELEV. MECHANICALLY COMPACTED) _25'x 12.8' 94.67 2 - 500 GALLON CHAMBERS WITH 4' OF STONE ALL AROUND ELEV. (25'x 12.8'x 2' DEEP) -GAS BAFFLE AT OUTLET TEE TEST HOLE LOGS ENGINEER: THOMAS McLELLAN, RE WITNESS: AMY VON HONE, R.S. DATE: 4-14-16 PERCOLATION RATE: < 2 MIN/IN NOTES: TH-1 98.0 FILL ELEV. 'IT 97.0 O/A HORIZON LOAMY SAND 18" 10YR 3/3 96.5 B HORIZON LOAMY SAND 36" 10YR 5/8 95.0 C HORIZON MEDIUM SAND 2.5Y 7/4 132"I 187.0 NO GROUND WATER ENCOUNTERED. 1. VERTICAL DATUM: ASSUMED 2. MUNICAPAL WATER IS AVAILABLE. 3. SCHEDULE 40 4' PVC PIPE TO BE USED THROUGHOUT SEPTIC SYSTEM. 4. ALL PRECAST UNITS SUBJECT TO TRAFFIC LOADS TO CONFORM WITH AASHTO H-20 SPECIFICATIONS. 5. PIPE PITCH = 1/4" PER FOOT (UNLESS NOTED OTHERWISE). 6. FIRST 2' OF PIPE OUT OF D -BOX TO BE SET LEVEL. 7. THE SEPTIC SYSTEM HAS NOT BEEN DESIGNED TO ACCOMODATE THE USE OF A GARBAGE DISPOSAL. 8. ALL CONSTRUCTION DETAILS ARE TO BE IN CONFORMANCE WITH THE STATE OF MASS. ENVIRONMENTAL CODE (TITLE FIVE) AND LOCAL HEALTH REGULATIONS. 9. CONTRACTOR TO VERIFY LOCATIONS OF ALL UTILITIES PRIOR TO CONSTRUCTION. 10. GROUND COVER OVER ALL SEPTIC SYSTEM COMPONENTS NOT TO EXCEED 31. 11. FIELD SURVEY PROVIDED BY TERRY A. WARNER, P.L.S., HARWICH, MA. 12. THIS PLAN REQUIRES THE REVIEW AND APPROVAL OF ONE OR MORE TOWN DEPARTMENTS AND IS SUBJECT TO CHANGE UNTIL SUCH TIME. 13. EXISTING LEACH. PIT IS TO BE PUMPED FILLED WITH SAND OR REMOVED. 14. D -BOX TO BE WATER TESTED TO ENSURE LEVELNESS AND EQUAL FLOW. SITE PLAN Yarmouth Health Department f LOCATION: p n `WEST YARMOUTH,MA PP VE1 F 13 HASTINGS AVE., PREPARED FOR: 7a fie Date s �§ BEVERLY HALEY DATE: 4-13-16 REVISED: 5-2-16 OCATION OF LEACH AREA SCALE: 1" = 20' BASS RIVER ENGINEERING -H MAS J. Mc LE AN, P.E. P.O. BOX 1163, EAST DENNIS, MA 02641 508-364-9048