Loading...
HomeMy WebLinkAboutEngineered Plan - 2009N LOCUS KEY: 4 EXISTING CONTOUR: - - - - PROPOSED CONTOUR: ............. a� MFRc EXISTING SPOT ELEVATION: 25.5 �RYOR PROPOSED T ELEVATION: 25.5 TEST Q UTILITY POLE -0- FENCE LINE: - p HYDRANT: �- RETAINING WALL:o LOCATION MAP LOT 1 (17,603 SF) ASSESSORS MAP: 59 PARCEL: 244 PLAN BOOK: 211, PAGE: 1 FLOOD ZONE: C KIT. KIT. LIVING LIVING ROOM ROOM BATH BATH 2nd FLOOR BED BED ROOM ROOM BED BED ROOM ROOM SEPTIC SYSTEM DESIGN FLOW ESTIMATE: 4 BEDROOMS AT 110 GAL / DAY = 440 GAL / DAY SEPTIC TANK: 440 GAL / DAY -A-2- DAYS = 880 GAL USE 1500 GALLON SEPTIC TANK (EXISTING) rLEACHING AREA: USE 3 500 GALLON CHAMBERS (8.5'x 4.8'x 2' EFF. DEPTH) WITH 4' OF STONE ALL AROUND (33.5'x 12.8'x 2' DEEP) SIDE AREA: (33.5' + 12.8') x 2 x 2 = 185 SF (0.74) = 137 GAL/DAY BOTTOM AREA: 33.5'x 12.8'= 429 SF (0.74) =-117 GAUDAY CAPACITY = 454 GAUDAY EDGE OF POND, ELE- 0.2 9 X91 1-x_ ,---- b11 iOrn bank (ea tOp bank \ ge of wet/. \ \1 SEPTIC SYSTEM SECTION 102.8 TOP OF ; FOUNDATION 100.7 a ELEV. 99.95 ELEV. 1500 GAL SEPTIC TANK TEE SIZES: (TO BE CONFIRMED) INLET: 6" UP 13" DOWN OUTLET: 6" OP, 14" DOWN COVERS OF FINIS 1st FLOOR 2nd FLOOR nd) _ "Q) _ , \ \ -1 E1LEV• \ bo mbank __\ \ __93 ENGINEER: THOMAS McLELLAN, P.E. 91, 10YR 4/1 100.2 L HORIZON LOAMY SAND EXISTING\ `` �_ -_ _ \ 161.10' 98.5 1500 GALLON �- '- - - SEPTIC TANK g0�b ' - - - - to _ '- - _ i a- nk- \ N 88°38'00" E BENCHMARKAT RIGHT CORNER MEDIUM SAND \ \ `-94 \ BOTTOM STEP _ USGS GROUND WATER ADJUSTMENT: ELEVATION = 102.5 WELL: MIW-29, ZONE: A, ADJUSTMENT: 1.1 ADJUSTED GROUND WATER ELEV.= 91.3 1132"1 90.0 WATER ENCOUNTERED -96 _�\ - --- LP�G4°° if _ 0 0 \\ / \;`LPA �- 40 Z(f) I 1 X BENCHMARK AT -' RIGHT CORNER BOTTOM STEP ELEVATION = 102.66 M9-16 m toapp /4" 1oti GRAVEL DRIVE ' TH-1 a� Ohe ;-c- 7 o, !"z S ' IvIcLLLLr � 1' CIVIL ' a.3710 G�� THOMAS J. MOLE& IAN, P.E 2" PEASTONE THIN 6 3/4" - 1 1/2" D GRAD WASHED STONE ;a INSPECTION PORT ELEV.= 99.4 1/8" of COVER saa ,ate .tea„ > ft (1' MIN) G-7 LEV. 99 0 98.83 ELEV. ELEV. Ad 96.4 D -BOX 4 <-> ELEV. 33.5'x 12.8' 3 - 500 GALLON CHAMBERS WITH 98.4 4' OF STONE ALL AROUND 5.1' ELEV. (33.5'x 12.8'x 2' DEEP) -GAS BAFFLE (H-20) AT OUTLET TEE adjusted ground water elevation = 91.3 TH-1 ---------- - O/AHORIZON a� Ohe ;-c- 7 o, !"z S ' IvIcLLLLr � 1' CIVIL ' a.3710 G�� THOMAS J. MOLE& IAN, P.E 2" PEASTONE THIN 6 3/4" - 1 1/2" D GRAD WASHED STONE ;a INSPECTION PORT ELEV.= 99.4 1/8" of COVER saa ,ate .tea„ > ft (1' MIN) G-7 LEV. 99 0 98.83 ELEV. ELEV. Ad 96.4 D -BOX 4 <-> ELEV. 33.5'x 12.8' 3 - 500 GALLON CHAMBERS WITH 98.4 4' OF STONE ALL AROUND 5.1' ELEV. (33.5'x 12.8'x 2' DEEP) -GAS BAFFLE (H-20) AT OUTLET TEE adjusted ground water elevation = 91.3 NOTES: 1. VERTICAL DATUM: ASSUMED 2. MUNICAPAL WATER IS AVAILABLE. 3. SCHEDULE 40 - 4" PVC PIPE TO BE USED THROUGHOUT SEPTIC SYSTEM. 4. ALL PRECAST UNITS SUBJECT TO TRAFFIC LOADS TO CONFORM WITH AASHTO H-20 SPECIFICATIONS. 5. PIPE PITCH = 1/8" PER FOOT (UNLESS NOTED OTHERWISE). 6. FIRST 2' OF PIPE OUT OF D -BOX TO BE SET LEVEL. 7. THE SEPTIC SYSTEM HAS NOT BEEN DESIGNED TO ACCOMODATE THE USE OF A GARBAGE DISPOSAL. 8. ALL CONSTRUCTION DETAILS ARE TO BE IN CONFORMANCE WITH THE STATE OF MASS. ENVIRONMENT CODE (TITLE FIVE) AND LOCAL HEALTH REGULATIONS. 9. CONTRACTOR TO VERIFY LOCATIONS OF ALL UTILITIES PRIOR TO CONSTRUCTION. 10. GROUND COVER OVER ALL SEPTIC SYSTEM COMPONENTS NOT TO EXCEED 3'. 11. FIELD SURVEY PROVIDED BY TERRY A. WARNER, P.L.S., HARWICH, MA. 12. THIS PLAN REQUIRES THE REVIEW AND APPROVAL OF ONE OR MORE TOWN DEPARTMENTS AND IS SUBJECT TO CHANGE UNTIL SUCH TIME. 13. EXISTING LEACH PITS ARE TO BE PUMPED AND FILLED WITH SAND OR REMOVED. 14. D -BOX TO BE WATER TESTED TO ENSURE LEVELNESS AND EQUAL FLOW. �0 FE u JUL 242009 HEALTH UEr i �m�����'(NOfP9gSS1CyG "� �O TERRY �� WARNER N _\ No. 38721 Jk SITE PLAN LOCATION: 54-56 MERCURY DRIVE, S. YARMOUTH, MA PREPARED FOR: GORDAN KWOK DATE: 6-19-09 SCALE: 1" = 20' BASS RIVER ENGINEERING TERRY A. WARNER, P.L.S. P.O. BOX 1163, EAST DENNIS, MA 02641 508-385-3426 TH-1 TEST HOLE LOGS O/AHORIZON E1LEV• LOAMY SAND ENGINEER: THOMAS McLELLAN, P.E. 91, 10YR 4/1 100.2 L HORIZON LOAMY SAND WITNESS: PHILIP RENAUD, R.S. DATE: 6-18-09 30" 10YR 6/8 98.5 C HORIZON PERCOLATION RATE: < 2 MIN/IN MEDIUM SAND 2.5Y 7/4 USGS GROUND WATER ADJUSTMENT: WELL: MIW-29, ZONE: A, ADJUSTMENT: 1.1 ADJUSTED GROUND WATER ELEV.= 91.3 1132"1 90.0 WATER ENCOUNTERED NO GROUND (POND ELEVATION = 90.2) NOTES: 1. VERTICAL DATUM: ASSUMED 2. MUNICAPAL WATER IS AVAILABLE. 3. SCHEDULE 40 - 4" PVC PIPE TO BE USED THROUGHOUT SEPTIC SYSTEM. 4. ALL PRECAST UNITS SUBJECT TO TRAFFIC LOADS TO CONFORM WITH AASHTO H-20 SPECIFICATIONS. 5. PIPE PITCH = 1/8" PER FOOT (UNLESS NOTED OTHERWISE). 6. FIRST 2' OF PIPE OUT OF D -BOX TO BE SET LEVEL. 7. THE SEPTIC SYSTEM HAS NOT BEEN DESIGNED TO ACCOMODATE THE USE OF A GARBAGE DISPOSAL. 8. ALL CONSTRUCTION DETAILS ARE TO BE IN CONFORMANCE WITH THE STATE OF MASS. ENVIRONMENT CODE (TITLE FIVE) AND LOCAL HEALTH REGULATIONS. 9. CONTRACTOR TO VERIFY LOCATIONS OF ALL UTILITIES PRIOR TO CONSTRUCTION. 10. GROUND COVER OVER ALL SEPTIC SYSTEM COMPONENTS NOT TO EXCEED 3'. 11. FIELD SURVEY PROVIDED BY TERRY A. WARNER, P.L.S., HARWICH, MA. 12. THIS PLAN REQUIRES THE REVIEW AND APPROVAL OF ONE OR MORE TOWN DEPARTMENTS AND IS SUBJECT TO CHANGE UNTIL SUCH TIME. 13. EXISTING LEACH PITS ARE TO BE PUMPED AND FILLED WITH SAND OR REMOVED. 14. D -BOX TO BE WATER TESTED TO ENSURE LEVELNESS AND EQUAL FLOW. �0 FE u JUL 242009 HEALTH UEr i �m�����'(NOfP9gSS1CyG "� �O TERRY �� WARNER N _\ No. 38721 Jk SITE PLAN LOCATION: 54-56 MERCURY DRIVE, S. YARMOUTH, MA PREPARED FOR: GORDAN KWOK DATE: 6-19-09 SCALE: 1" = 20' BASS RIVER ENGINEERING TERRY A. WARNER, P.L.S. P.O. BOX 1163, EAST DENNIS, MA 02641 508-385-3426