HomeMy WebLinkAboutEngineered Plan - 2016I, INSPECTION NOTE: PRIOR TO FINAL INSPECTION BY THE ENGINEER, SYSTEM NEEDS TO BE COMPLETE INCLUDING BUILDUP FOR COVERS. 5' REMOVAL OF UNSUITABLE SOIL REQUIRED AROUND PERIMETER OF LEACHING FACILITY DOWN TO SUITABLE SOIL LAYER REPLACE WITH CLEAN MEDIUM SAND TO MEET SPEC'S OF 3 10 CMR 15.255(3) Top of Concrete Bound TBM EL = 50.0 (49,G) Lot 4G8 I 1 2, 1 3 1 ± Sq. Ft. Nlate�s� See Note house #25 TOF EL = 50.8 Full Foundation O 51 � 122.55 48 < ��(49.7) (48.4) -OHW - EL = 47.6 (47.4) c I UNDERGROUND UTILITY LINES �o) Q. DBS _ Sern Note o � 1 (49. SEPTIC TANK PC (47.5) DB �11 Garage 18 •o' ' 20 5' Paved i C Min o ( 20' Min J Remove 30"1 1 49x1 r d"' Pine Tree Patio I(49. ,J (49.3) IA 1 losed Porch g.0, SAS/) Crawl vent / Space O Top of Concrete Bound TBM EL = 50.0 (49,G) Lot 4G8 I 1 2, 1 3 1 ± Sq. Ft. Nlate�s� See Note house #25 TOF EL = 50.8 Full Foundation O 51 SOILS TO BE VERIFIED IN THE, Patio ' Exi5ting Outlet. -24- FIELD DURING CONSTRUCTION -OHW - EL = 47.6 �E 7.4) UNDERGROUND UTILITY LINES ' (49.2)- PC O _ Sern Note �TP FENCE TEST HOLE LOCATION 7`� SEPTIC TANK PC (47.5) DB �11 Garage .22) 1 Paved (45.9) f d"' _ /(49.34) (46.9) (48.3) "---�_ (47.0) 48, X 46 12o.oa W c 5 SOo35,20'� (44.6) VARIANCE REQUESTED Variances: 3 10 CMR 15.22 1 (7) General Construction Reciuirement5 for All System Components: I .) Variance to the 20' setback between the edge of the SAS and the ex15tmg building. An 14" setback 15 provided. A G' Variance 15 reclue5ted. 3 10 CMR 15.405(I)(a) Fl��r Pion Bed Bed #2 #I Bed Bath #3 (48.73) Enclosed Dining Porch 1 Living Kitchen 1 (49.0) EXISTING SPOT GRADE 1P 1 � (48.3 _OOe -24- NO -OHW - UNDERGROUND UTILITY LINES O PC O _ Sern Note �TP FENCE TEST HOLE LOCATION (49.2) SEPTIC TANK PC PUMP CHAMBER DB DISTRIBUTION BOX SAS .22) 1 Paved DIW f d"' _ /(49.34) (50.6) (48.2) (48. Garage 70 (4 .5 Permit valid for REPAIR 0SE,PTIC SYSTIEM ONLY due .to State and Local septic variances. Board of I.ealth review and approval is required f()r fit" any; future additions/revue ationsialteratons to sewage facilities and/or structures/dwelling. v710 (7.6)� Q Yarmouth Heal)'h Department APPROVED(r*U( -fi 47.6) It C Datie (47.6 v1()11t-1 0 20 40 GO SCALE 1 "=20' 0ea/ad Yarmouth, MA Locus Map N.T.S. I .) Assessor's Map G7 Parcel 12G 2.) Book 9807 Page 73 3.) Plan Book 249 Page 1 13 4.) This property 15 in a Zone II Public Water Supply. 5.) This property 15 not in a Flood Zone LEGEND (48.3) EXISTING SPOT GRADE 24x5 PROPOSED SPOT GRADE -24- PROPOSED CONTOUR -OHW - OVERHEAD UTILITY LINES UNDERGROUND UTILITY LINES GAS SERVICE LINE EDGE OF CLEARING �TP FENCE TEST HOLE LOCATION ST SEPTIC TANK PC PUMP CHAMBER DB DISTRIBUTION BOX SAS SOIL ABSORPTION SYSTEM Prepared for: Linda May 9 Tucker Street Natick, MA 01 760 Proposed Sewage DI5p05011 System 25 Capt Wright South Yarmouth, MA 02@73 Prepared by: All Cape Septic LLC G 18 Route 28 West Yarmouth, MA 02673 (50(5) 771-4200 Emall: allcape5eptic@6jmall.c0m Date: OG/08/1 G Sheet I of 2 By: MA Check: 5M Project No. AC -60 TOP OF FOUNDATION EL = 50,8 47.3 INVERT EL Ecj INVERT EL X15tin To Remain I 101± I MINIMUM 20" DIAMETER CONCRETE COVERS RAISED TO WITHIN 6" OF FINISH GRADE (OR AS NOTED) EXISTING EL 49. 1 ± OVER PRECA5T Top 48.3 f LIQUID LEVEL 1O 14"z_ EXISTING 4"- EXISTING CONCRETE BAFFLE -� TEE AND GAS BAFFLE AT OUTLET EX15tincj 1,000 Gal 5ept)c Tank To Remain CONSTRUCTION NOTES 1.) ALL WORK SHALL CONFORM TO THE STATE ENVIRONMENTAL CODE, TITLE 5 (31 O CMR 15.000): STANDARD REQUIREMENTS FOR THE SITING, CONSTRUCTION, INSPECTION, UPGRADE, AND EXPANSION OF ON-51TE SEWAGE TREATMENT AND DISPOSAL SYSTEMS AND FOR THE TRANSPORT AND DISPOSAL OF SEPTAGE, AND THE LOCAL BOARD OF HEALTH REGULATIONS. 2.) ANY SEPTIC SYSTEM COMPONENT INSTALLED IN A LOCATION WHERE THERE 15 POTENTIAL FOR VEHICLES OR HEAVY EQUIPMENT TO PASS OVER IT SHALL BE DESIGNED TO WITHSTAND AN H-20 LOADING. IF UNDER AN IMPERVIOUS SURFACE, SYSTEM SHALL BE VENTED TO THE ATMOSPHERE. 3.) TO MINIMIZE UNEVEN SETTLING, SEPTIC TANK5 SHALL BE INSTALLED ON A STABLE MECHANICALLY -COMPACTED BASE ON 51X INCHES OF CRUSHED STONE. 4.) COVERS OVER THE INLET AND OUTLET TEES OF THE SEPTIC TANK, THE D15TRJBUTION BOX, AND THE 501L ABSORPTION SYSTEM SHALL BE RAISED TO WITHIN G" OF FINAL GRADE. LEACHING FIELDS, TRENCHES, AND OTHER 501L ABSORPTION SYSTEMS WITHOUT ACCESS MANHOLES SHALL HAVE AT LEAST ONE (1) INSPECTION PORT CONSISTING OF PERFORATED 4" PVC PIPE PLACED VERTICALLY TO THE BOTTOM OF THE 501L ABSORPTION SYSTEM WITH A CAP, TIED WITH MAGNETIC MARKING TAPE, ACCE55151 F TO WITHIN 3" OF FINAL GRADE. 5.) PIPING SHALL CON515T OF 41 SCHEDULE 40 PVC OR EQUIVALENT. PIPE SHALL BE LAID ON A MINIMUM CONTINUOUS GRADE OF NOT LE55 THAN 2% FROM THE BUILDING TO THE SEPTIC TANK, AND NOT LE55 THAN I % OTHERWISE. G.) DISTRIBUTION LINE5 FOR THE 501L ABSORPTION SYSTEM SHALL BE 4" DIAMETER SCHEDULE 40 PVC (OR EQUIVALENT) LAID AT 0.005 FT/FT. UNLESS OTHERWISE NOTED. UNES SHALL BE CAPPED AT END OR AS NOTED. 7.) LINES FROM THE DISTRIBUTION BOX TO BE LEVEL FOR THE FIRST TWO (2) FEET BEFORE PITCHING TO THE SOIL ABSORPTION SYSTEM. DISTRIBUTION BOX SHALL BE WATER TESTED TO ASSURE EVEN DISTRIBUTION. 8.) GROUT TO BE USED AT ALL POINTS WHERE PIPES ENTER OR LEAVE ALL CONCRETE STRUCTURES IN ORDER TO PROVIDE A WATERTIGHT SEAL. 9.) HEAVY EQUIPMENT SHALL NOT BE ALLOWED TO OPERATE OVER THE LIMITS OF THE SEWAGE DISPOSAL FIELD DURING THE COURSE OF CONSTRUCTION OF THE SYSTEM. 10.) IN ACCORDANCE WITH 31 O CMR 15.22 1 , ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC MARKING TAPE. I J.) THERE ARE NO KNOWN WELLS WITHIN 100 OF THE PROPOSED SOIL ABSORPTION SYSTEM. 12.) FROM THE DATE OF THE INSTALLATION OF THE SOIL ABSORPTION SYSTEM UNTIL RECEIPT OF THE CERTIFICATE OF COMPLIANCE, THE PERIMETER SHALL BE STAKED AND FLAGGED TO PREVENT USE OF THE AREA THAT MAY CAUSE DAMAGE TO THE SYSTEM. 13.) THE DESIGNER WILL NOT BE RESPONSIBLE FOR THE SYSTEM AS DESIGNED UNLESS CONSTRUCTED AS SHOWN ON PLAN. ANY CHANGES SHALL BE APPROVED IN WRITING BYTHE DESIGNER. 14.) THE BOARD OF HEALTH REQUIRES INSPECTION OF ALL CONSTRUCTION BY AN AGENT OF THE BOARD OF HEALTH AND THE DESIGNER. THE DESIGNER SHALL CERTIFY IN WRITING THAT THE SEWAGE DISPOSAL 5Y5TEM WAS INSTALLED IN ACCORDANCE WITH THE TERMS OF THE PERMIT AND THE APPROVED PLANS. 48 HOURS ADVANCE NOTICE 15 REQUESTED. 15.) LOCATION OF UTILITIES IS APPROXIMATE AND CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING THE LOCATION OF ALL UNDERGROUND AND OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF ANY WORK. THIS INCLUDES, BUT 15 NOT LIMITED TO, REQUESTS TO DIG5AFE, ANY PRIVATE UTILITY COMPANIES, AND THE LOCAL WATER DEPARTMENT. I G.) CONTRACTOR SHALL VERIFY THAT ALL WA5TEUNE5 ARE CONNECTED BY WATER TESTING WITHIN THE DWELLING PRIOR TO INSTALLATION OF ANY SEPTIC COMPONENTS. 17.) CONTRACTOR SHALL VERIFY EXISTING INVERT ELEVATIONS PRIOR TO INSTALLATION OF ANY SEPTIC SYSTEM COMPONENTS. I8.) TEST HOLES COMPLETED PER STATE ENVIRONMENTAL CODE, TITLE 5. SOILS CAN BE VARIABLE AND TEST HOLE DATA 15 NO GUARANTEE OF SOIL CONDITIONS IN OTHER AREAS. if SOILS DIFFER FROM TH05E SHOWN IN THE SOILS LOGS, DESIGN ENGINEER IS TO INSPECT THE SOILS PRIOR TO PROCEEDING WITH INSTALLATION OF ANY SEPTIC COMPONENTS. 19.) EXISTING SEPTIC COMPONENTS TO BE LOCATED, PUMPED DRY, FILLED WITH CLEAN SAND AND ABANDONED IN PLACE OR REMOVED AS REQUIRED. AREA TO BE COMPACTED TO MINIMIZE 5ETTLIN( 20.) WATER/5EWER CROSSING: 2" PVC WA5TELINE SHALL BE SLEEVED IN A 207 SECTION OF 4" PVC PIPE CENTERED OVER THE WATER LINE TO MAXIMIZE DISTANCE TO JOINTS. Install alarm t control box Inside of bldg on 5eparate Circuit All electrical mrmg for the pump and alarm is to be in conduit D -Box Riser Extension PROVIDE THREE INSPECTION PORTS TO Manhole cover to grade shall be to within G" of grade WITHIN 3" OF FINAL GRADE steel cover and bolted to collar 2" F.M. 4± Expander MINIMUM 9" OF COVER 4.7,7± (21x4") � 47.9 (5ee Detail) 2" PVC 47,0 5 Emergency 42pa Off. �I,E7 E 57 INVERT EL INVERT EL 4 EL ty2Gallon 4,6.5 Capaaff Above AdamINVERT WEEP HOLE 1/4° 05TONE BA5E Actual Groundwater Level INVERT EL Tna2 CONTROL ROAD 2T�,o" CHECK VALVE AND GATE VALVE Proposed 46.6 C � 10'5.r 24° FUMF ON 22"-2811 D -Box {\ \( 42.5 21'FUMP OPP SEWAGE PUMP, MYERS SRM} OR EQUIVAllNT) (DB 5) 1 10, Longest RU G* 5TONE EASE 0.0 % Slope I 12' 3/41 TO 1-1/2' DIA. Proposed 1 ,000 Gal H-10 FLOW PROFILE Pump Chamber NOT TO SCALE Acme Preca5t Co. PUMP CHAMBER CALCS I (or 51mllar) CYCLES REQUIRED PER DAY = 5.4 DOSE VOLUME PER CYCLE REQUIRED = 62.4 GALLONS DOSE VOLUME PER CYCLE PROVIDED = 60.8 _ 30.5' __ IIV✓I LVlll/IV I VI\IJ Leaching Field Detail N.T.S, T r'f-T 1 A /11 r 1 1-%'-� PROPOSED V WITH CHARCOAL 48.4± ,Filter Fabnc (7.5'x 4-Unit5 + 0.5Installed, 30.5' Total Length Installed) TWELVE (12) 4-CULTEC CONTACTOR I OOHD (STONE LESS) CHAMBERS CONFIGURATION WITH THREE (3) ROWS OF FOUR (4) CHAMBERS 5.1' LEACH CHAMBER5 CULTIC CONTACTOR I OQHD UNITS EL=41.5 Adjusted Ground Water EL=41 ,0 Observed Ground Water EL=38.5 Bottom Test Hole PUMP AND ALARM NOTES I ) PUMP MUST BE INSTALLED ACCORDING TO MANUPACTUERIS SPECIFICATIONS. 2) USE MEYER OR GOULD 1/3 HP PUMP, OR EQUIVALENT 3) PUMP MUST BE CAPABLE OF PASSING 2" SOLIDS 4) ALARM MUST BE WIRED ON SEPARATE CURCUIT FROM PUMP. 5) ELECTRICAL WORK TO BE INSPECTED BY WIRING INSPECTOR. G) ALARM MUST BE LOCATED IN THE HOUSE. SYSTEM DESIGN CALCULATIONS Estimated H1cih Groundwater Calculation Index Well # AIW-230 Zone e Date of Readmej 5/1 G Depth to Groundwater 21 . I G Groundwater Adjustment 0.5 Actual Groundwater Level 41.0 Estimated High Groundwater 41.5 SEWAGE DE51GN FLOW REQUIRED: 3 BEDROOM DWELLING @ I 10 GPD / BEDROOM = 330 GPD REQUIRED SEWAGE DE51GN FLOW PROVIDED: TWELVE 4-CULTEC CONTACTOR I OOHD CHAMBERS IN BED CONFIGURATION IN THREE (3) ROWS OF FOUR (4) UNITS EACH CAPACITY = 12-CULTEC CONTACTOR I OOHD (3 ROWS OF 4 UNITS) = 91,5 LF 91.5 LF X 5.0 SF/LF = 457.55F 457.5 5F X 0.74 GPD/SF = 338.5 GPD 338 GPD PROVIDED > 330 GPD REQUIRED SEPTIC TANK CAPACITY REQUIRED: 330 GPD X 200% = 660 GPD REQUIRED SEPTIC TANK CAPACITY PROVIDED: 1000 GALLON SEPTIC TANK (EXISTING TO REMAIN) A GARBAGE DISPOSAL 15 NOT PERMITTED WITH THIS DE51GN FLOW Test Hole # I (EL=49.0±) I L -.J I I I kJ LL- LV V Depth Elev, Layer 5011 Cla55 Soil Color Comments 011-221' 47.2 HTM fill 22"-2811 46.7 NE Loamy Sand I OYR 3/2 Loamy 2811-42" 45.5 B Medium Sand 7.5YR4/G V. Friable 42"-12611 38.5 C Medium Sand I I 0YRG/6 I Clean, Loose Standing Groundwater Encountered @ 96" depth EL = 41 .0 DATE OF TESTING: 5/20/1 IS SOIL EVALUATOR: DAN CROTEAU - 513772 BOARD OF HEALTH AGENT: PHIL RENAUD PERCOLATION RATE: LE55 THAN 2 MIN/INCH IN "C11 LAYER AT 621 GROUNDWATER ENCOUNTERED AT 9G" DEPTH EL = 41 ,0 flan Veer N. rS Horz P, Tee 2" (DB 5) FM 4 ES�ande. (07W "> P wr Hwe D -Bax (DB 5) A55e55or51 Maa G7 Parcel 12G