Loading...
HomeMy WebLinkAboutEngineered Plans - 2016SURVEY REFERENCE: CERTIFIED PLOT PLAN BY EVERETT H. HINCKELY, RLS DATED 11/25/80 FLOOR PLAN SCALE: 1"=20' LEGEND 1`--®---� PROPOSED CONTOUR ® PROPOSED SPOT GRADE -- 98 -- EXISTING CONTOUR + 96.52 EXISTING SPOT GRADE W— EXISTING WATER SERVICE 0 TEST PIT SURVEY REFERENCE: CERTIFIED PLOT PLAN BY EVERETT H. HINCKELY, RLS DATED 11/25/80 FLOOR PLAN SCALE: 1"=20' RTE 28 LOCUS MAP LOCUS INFORMATION TITLE REF: BK 11900 PG 068 PLAN REF: BK 155 PG 093 PARCEL ID: MAP 039 PAR. 087 SEPTIC SYSTEM REPAIR PLAN LOCATED AT: 30 BUTLER AVENUE WEST YARMOUTH, MA PREPARED FOR SEAN GON SALVES JUNE 23, 2016 Mass %� DARNIN[1.9, r 1 1 MEYER & SONS, INC. P.O. BOX 981 EAST SANDWICH, MA. 02537 PH: (508)360-3311 FAX: (774)413-9468 meyerandsonstitle5@gmail.com www.meyerandsons.com SHEET 1 OF 2 J#1744 PNO 9D cr- LOCUS J 30 BUTLER AVE. o 0 o /,( Q V BUTLER AVE. I. c� RTE 28 LOCUS MAP LOCUS INFORMATION TITLE REF: BK 11900 PG 068 PLAN REF: BK 155 PG 093 PARCEL ID: MAP 039 PAR. 087 SEPTIC SYSTEM REPAIR PLAN LOCATED AT: 30 BUTLER AVENUE WEST YARMOUTH, MA PREPARED FOR SEAN GON SALVES JUNE 23, 2016 Mass %� DARNIN[1.9, r 1 1 MEYER & SONS, INC. P.O. BOX 981 EAST SANDWICH, MA. 02537 PH: (508)360-3311 FAX: (774)413-9468 meyerandsonstitle5@gmail.com www.meyerandsons.com SHEET 1 OF 2 J#1744 F1 x, R NOTE: MAGNETIC TAPE TO BE PLACED OVER ALL COVERS T.O.F. EL.=100.0± SEPTIC TANK PROPOSED D -BOX INSTALL RISERS & COVERS OVER INLET & INSTALL RISER & COVER OUTLET AND SET TO 6" OF FINISH GRADE SET TO 6" OF GRADE F.G. EL.=98.0± F.G. EL.=98.0± /- � F.G. EL: 97.50± 9" MIN COVER/ 36" MAX COVER L = 30' ® S=1% (MIN.) EL. 96.5 ®5=19. (MIN.) 4"SCH40 PVC - 4"SCH40 PVC LLLt0'I INV.=95.50 14" 1 H 4B' UQUID kNV.=95.25 LEVEL. GAS BAFFLE INV. --94.451 EXISTING 1.000 GALLON SEPTIC TANK EXIST. SEWER OUTLET INV.=97.0 NOTES: 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE INVERTS PRIOR TO CONSTRUCTION 2) D -BOX SHALL BE SET LEVEL AND TRUE TO GRADE ON A MECHANICALLY COMPACTED SIX INCH CRUSHED STONE BASE, AS SPECIFIED IN 310 CMR 15.221(2) 3) REPLACE EXISTING 1,000 GALLON SEPTIC TANK WITH 1500 GALLON SEPTIC TANK IF FAILED, DAMAGED, OR UNDERSIZED. L = 10'(MAX) 0 S=1% (MIN.) 4"SCH40 PVC 11.3- TO INVERT INV.=94.11 - PROPOSED D -BOX INV.=94.25 DB- LUM BREAKOUT=TOP ELEV.= 94.50 INV. ELEV.= 94.11 BOTTOM ELEV.= 93.17 NOTE: TO PREVENT BREAKOUT, THE PROPOSED FINISH GRADE SHALL NOT BE < EL: 94.50 FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE S.A.S. PROPOSED S.A.S. INSTALL A 4" DIAMETER INSPECTION PORT OVER GENERAL NOTES: ONE CHAMBER (MIN.) AND SET TO 3" OF F.G. F.G. EL: 97.5 (MAX.) 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V. AND ANY APPLICABLE INSTALL TWO INSPECTION PORTS (MIN.) LOCAL RULES AND REGULATIONS. 4 ROWS OF 4 UNITS AT 6.25'/UNIT = 25'/ROW SOIL ABSORPTION SYSTEM (PROFILE) STORE VEGETATIVE COVER BACKFILL WITH CLEAN PERC SAND TO TOP OF CHAMBERS 0 1 MYA PIA.- -1 b 9h-\ I •-- 5' MIN. ABOVE BOTTOM OF EXISTING SUITABLE MATERIAL T.P. EXCAVATION OR G.W. EFFECTIVE WIDTH = 4 x 2.83' = 11.321 (6.83' PROVIDED) USE 4 ROWS OF 4 -HIGH CAPACITY BOTTOM OF TESTHOLE: EL:86.50 = INFILTRATOR (H20) UNITS W/ ENDCAP-NO STONE 4) INSTALL INLET & OUTLET TEES W/ SEPTIC SYSTEM PROFILE GAS BAFFLE AS REQUIRED DESIGN CRITERIA NUMBER OF BEDROOMS: 2 BR DWELLING/3 BEDROOM DESIGN DESIGN FLOW: RESIDENTIAL: 3 BEDROOMS 0 110 GPD/BR = 330 GPD DESIGN PERCOLATION RATE: <2 MIN/IN SOIL TEXTURAL CLASS: CLASS I GARBAGE GRINDER: NO (not designed for garbage grinder) DISTRIBUTION BOX: USE DB -5 (1-120) N.T.S. (0.74 GPD/SF) SEPTIC TANK: 330 gpd x 200% = 660 gpd USE EXIST. 1,000G SEPTIC TANK LEACHING AREA REQUIRED: (330)/.74 = 445.94 S.F. PRIMARY S.A.S. USE 4 ROWS OF 4 - HI -CAP INFILTRATOR H-20 UNITS -NO STONE BOTTOM AREA: (GENERAL USE APPROVAL FOR 4.73 SF/LF OF CHAMBER) (CHAMBER) 16 UNITS x 6.25 LF x 4.73 SF/LF = 473.0 SF DESIGN FLOW PROVIDED: TYPICAL SECTION N.T.S. SOIL LOGS DATE: JUNE 22, 2016 SOIL EVALUATOR: DARREN M. MEYER, CSE 1614 WITNESS: A. VONHONE, YARMOUTH HEALTH TOTAL AREA = 473 SF 0.74GPD/SF(473SF) = 350 GPD > 330 GPD req'd Elev. TP -1 Depth 97.50 DRAWN 0" MEYER &SONS, INC. A DMM 06/23/16 LOAMY SAND REV DATE CHECKED 1OYR 4/1 508-362-2922 96.50 B 12" LOAMY SAND 1DYR 6/6 94.83 32' C MEDIUM SAND 2.5Y 6/4 86.50 132" PERC RATE <2 MIN/IN. (-Cl- HORIZON) NO GROUNDWATER OBSERVED • I, Darren M. Meyer. R.S., CSE, hereby certify that I am currently approved by MADEP pursuant to 310 CMR 15.017 to conduct soil evaluations and that the above analysis has been performed by me consistent with the requirements of 310 CMR 15.017. 1 further certify that I have passed the Soil Evol. Exam in October, 1999. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON ASSUMED DATUM. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. DWELLING IS SERVICED BY MUNICIPAL WATER SUPPLY. 8. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR. 9. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO STARTING WORK. 10. EXISTING LEACHING TO BE PUMPED, CRUSHED AND REMOVED PER TITLE 5. REPLACE WITH CLEAN MEDIUM SAND PER TITLE 5 REQUIREMENTS. 11. 48 HOUR NOTICE FOR ENGINEER CERTIFICATION 12. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY 13. NO KNOWN PRIVATE WELLS WITHIN 100 FT. OF PROPOSED LEACHING 14. ALL PIPING TO BE 4" SCH 40 0 1/8"/FT (UNLESS SPEC. ) 15. THE DESIGN OF THIS SYSTEM DOES NOT ALLOW FOR THE USE OF A GARBAGE GRINDER. 16. NO WETLANDS WITHIN 150 FT. OF PROPOSED LEACHING 16' SECTION INVERT HEIGHT END CAP INFILTRATOR - HI CAPACITY (H2O) CHAMBER 1 PROPOSED SEPTIC SYSTEM UPGRADE PLAN 1 30 BUTLER AVENUE, WEST YARMOUTH, MA Prepared for: Gonsalves System Design and Site Plan by: SCALE DRAWN DATE MEYER &SONS, INC. N.T.S. DMM 06/23/16 PO BOX 981 EAST SANDWICH, MA 02537 REV DATE CHECKED SHEET NO. 508-362-2922 DMM 2 Of 2