Loading...
HomeMy WebLinkAboutEngineered Plan - 2016SYSTEM PROFILE PROVIDE MIN. 20" DIAM. WATERTIGHT (NOT TO SCALE) ACCESS COVERS TO WITHIN 6" OF FIN. GRADE 2" PEASTONE OR GEOTEXTILE FILTER FABRIC OVER STONE 337. ►IIAII►II I►I AC !YN/CD !1\/CD ODClACT ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. CAST IRON COVER TO GRADE 4" SCH40 VENT WITH CHARCOAL FILTER AS NOTES SHOWN PLAN VIEW PITCH BACK TO SAS, 1. DATUM IS ASSUMED NO LOW POINTS. 2. MUNICIPAL WATER IS EXISTING 3 MINIMUM PIPE PITCH TO BE 1/8" PER FOOT 2% SLOPE REQUIRED OVER SYSTEM T NOTE: 2" MIN. WALL4. DESIGN LOADING FOR ALL PROPOSED PRECAS PRECAST H-10 THICKNESS REQUIRED 2' CAST IRON COVERS TO GRADE OR CONCRETE UNITS TO BE AASHO H—ZQ RISERS (TYP.)COVERS TO. WITHIN 6" GRADE, COORDINATE W/ OWNER 2'o 4"OSCH40 PVC MORTAR ALL _ 6" MIN. SUMP PIPES LEVEL 1ST 2' COMPONENTS 5. PIPE JOINTS TO BE MADE WATERTIGHT. 12" MIN. INT. DIM. 4' (TYP.) 6[—SIDES 4' , ENDS ° 35.16 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE II ➢°oo�oo'"ap°".ego . *35.56 10" 1500 GAL H-20 14 ;, °o°o°°°° ° .. . , :. 00000o WITH 310 CMR 15.000 (TITLE 5.) 34.96' TEE SEPTIC TANK TEE ° ° ° ° ���® ���� ®C�lM�——!](�0°°°°°° 4.71 °°°°°°°° 0��®�Da0�00 aaPf"].i.010 °°o°o°o°o°o°o WATERTEST D BOX O ;°o°o°O°O Baa®�ao�o®® ®®M®0�0��o�°�7. THIS PLAN IS FOR PROPOSED WORK ONLY AND 0 0 0 0 0 0 0 0 0 0 (� O O (� O O 0 0 0 0 00 0 0GAS BAFFLE �' °o��o°°°o° FOR LEVELNESS �i i�°°o°000°o°°o0 00®® 000®0� ���0�0���0000000°orNOT TO BE USED FOR LOT LINE STAKING OR ANY ° ° ° °32.16 OTHER PURPOSE. .•4 LIQ. LEVEL (ACME"OR EQUAL) ':34.46' 34.29' >°o °o°o°°°°°° ' 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 000000000000000000000000000000°0°00000°000000 �0000�00�0�0,°,0�0^0.00000000000�0�000000000000 H-20 500 GAL. LEACHING CHAMBER BY ACME PRECAST OR EQUAL. 3/4"-1-1/2" DOUBLE WASHED STONE 4' MIN. (2) UNITS REQUIRED 9. COMPONENTS NOT TO BE BACKFILLED OR ALL AROUND PRECAST STRUCTURES CONCEALED WITHOUT INSPECTION BY BOARD OF 6" CRUSHED STONE OR MECHANICAL OVERALL DIMENSIONS TO OUTSIDE OF STONE: 25.00' X 12.83' co HEALTH AND PERMISSION OBTAINED FROM BOARD (2.5% SLOPE) FOUNDATION— 24' SEPTIC TANK LEGEN D 99— EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. —[991— PROPOSED CONTOUR 198.41 PROPOSED SPOT EL. TH1 TEST HOLE 2� SLOPE OF GROUND UTILITY POLE FIRE. HYDRANT NOTE: NOT All SYMBOLS MAY APPEAR IN DRAWING TEST HOLE LOGS COMPACTION. (15.221 [21) ( 1 % SLOPE) H-20 — 25 D' BOX (—!—% SLOPE) 15' *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM ENGINEER: CRAIG J. FERRARI, SE #13871 WITNESS: PHIL RENAUD (BoH) DATE: 5/5/2016 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS Q ELEV. Ott 1 37.5' A LS 12" 1OYR 3/2 B LS 2211 1OYR 6/8 35.7' PERC C MS 1OYR 7/4 132" I 126.5' NO GROUNDWATER ENCOUNTERED DCE #16-124 Scale: 1"= 20' 0 10 20 30 40 50 FEET LEACHING FACILITY PROP. VENT WITH CHARCOAL FILTER AND BUGSCREEN (FINAL PLACEMENT BY CONTRACTOR WTH OF HEALTH. to 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND 26.5' BOTTOM TH-1 VERIFYING THE LOCATION OF ALL UNDERGROUND & NO GROUNDWATER FOUND OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED. KITCHEN LOCUS MAP NOT TO SCALE ASSESSORS MAP 79 PARCEL 31 VARIANCES REQUESTED: UNDER MAX. FEASIBLE COMPLIANCE 15.405: (1b): REDUCTION IN SETBACK, SAS TO FOUNDATION (20' TO 17.3') BATH BEDROOM SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED LIVINGROOM DESIGN FLOW: 3 BEDROOMS @ 110 GPD = 330 GPD - BEDROOM - -USE A 330 GPD DESIGN FLOW - - BEDROOM I I SEPTIC TANK: 330 GPD (2) = 660 FLOORPLAN USE A 1500 GAL. SEPTIC TANK NOT TO SCALE LEACHING: SIDES: 2 (25 + 12.83) 2 (.74) = 112 GPD BOTTOM 25 x 12.83 (.74) = 237 GPD TOTAL: 472 S.F. 349 GPD USE (2) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH 4' STONE ALL AROUND APPROVED Permit valid for REPAIR t)1' SEP FIC SYtil 1.M ONLY; d'ue to State and Local septic variances. Board of Ilealth review and approval is required for any, future auditions/'renovations/alterations to sewage facilities and/or structu, es/dwelling. Yarmouth t1e1111) I))cpartlllelnt VV 0 (--27-79 dttmc Date C5-1-1 -1 L DATE STpv DANIEL A. A. OJALA, P.E., P.L.S. , MA DATE BOARD OF HEALTH TITLE 5 SITE PLAN OF #56 RAYMOND AVENUE SOUTH YARMOUTH, MA PREPARED FOR SHARON GRUNDY DATE: MAY 17, 2016 off 508-362-4541 fax 508-362-9880 downcape.com dote cnpo entinefring, inc. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 16-124