Loading...
HomeMy WebLinkAbout83- 796 - Design FlowAY —.. 1 i a Locus Ul Cove Expansion Pit P Leachlrty Pit ElSeptic Tank .r+•�•./00' Line �•••"�50' Line --30' Line —•—��Top of Bank (Gs determined by Conservation. See notice Of Intent on Memo.) ✓V U U / 1 / 1Vrr Hay 8ailes —Roof Drains to dry wells. —All Driveways have been stokes angled into ground calculated to drain to streets and street drain system. Profile Hay Bolls Double Row' I I'. Set staggered and Double Stake to ground PLAN Not to SC ale See calculations for Subdivision and Planning Board Filing Working Sot/ Tests made for Septic System Permit Procedures in front Lot in Area of Proposed System on June /7th /987 showed the soil to be O"-30" Loom 8 "Subsoil" 30"- 144" Clean Coarse Sand. No water encounted Perculat/on Rote Less than 2min/inch 4" P fro m 4" PVC from /. D / 0// 6' 6" 12,0 / O. D /0/ 6" Working Diameter Pit Ground Surface -�:2 Pit L Pit Detail PLAN -/ /2 Stone I Working Area Bottom 7rr 2 = 86.59 Side Mdh = 197.92 Allowable Load Bottom / Gal. per S. F Side 2.5 Gal. per S. F To tol 86.59 x / = 86-59 Gots. TEST BY 197.92 x 2.5 = 494.80 Gals. ---/2" minimum depth if this is more than /2111he cover shot/ be extended to within l2" of ground surface. -2"- l/8" Stone —Alt Stone to be washed free of Iron, "Fines" and Dust 3/4 "- 1'/2" Stone —All structures to be precast concrete If under areas of vehicular traffic design for H2O loading. —All pipe to be PV.0 - if under areas of vehicular traffic use schedule 40 SECT/ON Scale /"- 40' SEPTIC TANK DETAIL NOT TO SCALE NOTES !1 SEPTIC TANK SHALL BE 4 INLET AND OUTLET TEES TO BE CAST IRON OR REINFORCED CONCRETE. SCHED 40 PVC 2 SEPTIC TANK TO WITHSTAND H-10 LOADING TO BE CENTERED UNDER MANHOLE COVER UNLESS UNDER PAVEMENT, DRIVES OR 5 1000 GAL, TANK. SHOWN OR ANY OF EQUAL TRAVELED. WAYS, WHEREIN H-20 LOADING SHALL APPLY. CAPACITY APPROVED 3 ALL PIPE CONNECTIONS AND CONCRETE MANHOLE COVER CONSTRUCTION TO BE WATERTIGHT WITHIN 12' FINISH GRADE 8' 0" 14 T L - _7 WATER LEVEL - - - - - - - - - - — - - -i 15 2" I _ INLET TEE PRECAST — 46 4'_d' OUTLET NK � — TA — �` 5'6° LIQUID DEPTH TEE ,. 110 / o0 BOTTOM ON LEVEL STABLE BASE PLAN VIEW rRncc-cvrnrw v/rm DESIGN CRITERIA DESIGN FLOW 4 BR x 110 Gal./BR 2 440 Gol/Day REQUIRED SEPTIC TANK 440 x 1.5 = 660 GAL. SEPTIC TANK PROVIDED = 1000 GAL, SIZE OF LEACHING FACILITY REQUIRED DESIGN PERC.RATE - 2 MIN./INCH LeacAin P/I's !0.5 /ometer SIZE OF LEACHING FACILITY PROVIDED 2 Pits at f0.5 diameter x 6 dee d SOIL TEST PIT DATA INDICATES INDICATE PERK -- OBSERVED TEST. OROUNDWATER TP TP TP TP GRD. EL. GRD. EL GRD EL GRD EL GW EL GW EL GW EL JI(GW. EL. Loam Subsoil Test Sand No Water I IJ 1 LINE DATE DATE DATE 6/17/87 TEST BY TEST TEST BY TEST BY WITNESSED BY WITNESSED BY WITNESSED BY WITNESSED BY Health Agent PERC RATE PERC RATE PERC RATE FERC RATE 2 MIN/INCH MIN/INCH —MIN /INCH MIN/INCH REVISION DATE ACHECKEDBY: Lot 9 on Oystel. Cove on Boss Rive O 40 80for Conservation Commissio} (,&e T: 8644 Graphic Scale "� DATE: 05129187 __ BRIAN y ;g MCSV;IEENEY HIDELL-EYSTER TECHNICAL SERVICES;NC. DRAWINGNO: 'o • .No.IB�S VIL 198 WHITING STREET A q E� k C/ HINGHAM , MASSACHUSETTS 0204: (617) 749-8040 ^ate'