HomeMy WebLinkAbout83-699 - Sewage Disposal SystemSOIL TEST TOP OF FOUND. 20 FT. MIN.
LOT 2,1- LOT z� L_OT ZS LST Z4 EL = /OF7. = 10 FT. MIN. 44
OBSERVATION HOLE I OBSERVATION HOLE 2 OBSERVATION HOLE 1 LnT ZS rLt
Lz. T
rr'S
CONCRETEO P 1^ ,
DATE OF TEST 5'2 SS DATE OF TEST S -2.9C DATE OF TEST 2'`i COVERS 4 SCH 40 PVC CLEAN SAND 4
PIPE- MIN. PITCH
WITNESSED BY 5 R WITNESSED BY S R. WITNESSED BY S I/8 PER FT CONCRETE
PERC. RATE « MIN./ INCH PERC. RATE �Z MIN./INCH PERC. RATE z MIN./INCH COVERS
`__ ELEV.= `tS 4 1r 2 0 4 CAST IRON (OR
ELEV = ' ELEV.=_ EQUAL) PIPE- MIN. 212 MAX -
o
0 p PITCH I/4 PER FT. 1 j_OGUS
2% MIN
TU? f tJ $OlL It1F .4 <L}Lj Sa Vit.
S [� �GtL TC:PS t<
HARD PUCK 4 C_LAy cLr:Y,PErN; c P.!.}C.1,5 i" D D FLOW LINE LEVEL
(UNSliITAI?LE) UIISUIT ARLE)
e i t
79'• EL- =ip
J1j� EL= EL
IL _
z.� V a: �MI'N. � o:.:.;o. e.N � •/O' p �ot� Ro
)08.0 EL= /09.3 c = — "= lvl�tte¢N
EL- 100.6 107.5
�nsDtvv, To 1pmt;< SATiD t3a" CLI eA.7. 1D7 7 EL= /cooEL - 99.8 0
MEbPJM S%tTtD "Y S1 LT 10.7.2—c a olel 7
0
Mcotuna 5t,�D EL= 99.6 0 0
DIST-E o
Iqa" EL' 0q 8 1aa• -L , ��.4 144` �L- `a z BOX a 5 � n LOCATION MAP
WATER AT. EL= WATER AT EL= WATER AT EL=
}� H,C ND PERCHED Qvr'TE�'. f•T • Iv H FNCa 10 GAL n
11`1• ELI 88 41 PRECAST LEACHING o �, _
oaY ry ?t�M SEPTIC BASIN OR EQUIV. EL= _ LEGEND
_ TANK EXISTING SPOT ELEVATION Cop
L_� i Z S_
)G' �,A EXISTING CONTOUR - - --DO- - - -
0r?Sr._'r�Y/� ION FINAL SPOT ELEVATION 00.
r _ c FINAL CONTOUR n
PROFILE OF
t(ylT, `=w<tL) /_�;R BOTTOM OF TEST HOLE OR OBSERVED WATER TABLE EL = 83 �r SOIL TEST LOCATION
GH SEWAGE DISPOSAL SYSTEM ADJUSTED GROUND WATER TABLE ( / / ) EL = TELEPHONE POLE
NOT TO SCALEHYDRANT (>
TOWN WATER —W--- —W
_ o
CATCH BASIN
7c,PSOIL ':" FRAME & COVER SHALL BE
4•• SET WITH MASONRY UNITS
CLEAN SAND WHICH ARE TO BE MORTARED
IN PLACE
GENERAL NOTES:
rs
2
I. ALL WORKMANSHIP AND MATERIALS SHALL
1/8"- I/2�� WASHED LAYER OF
STONE CONFORM TO D.E.Q.E. TITLE 5 AND THE
TOWN OF YA2M00-th RULES a REGULATIONS
A
FOR THE SUBSURFACE DISPOSAL OF SEWAGE
i}h` ELS 73 .Ie ll t� Al
} a 2.ALL COVERS TO SANITARY UNITS SHALL BE
:L fi a 0 BROUGHT TO WITHIN 12° OF FINISHED GRADE
3/4% 1 1/2" 3.EXISTING AND FINAL GRADES SHALL REMAIN
WASHED STONE ESSENTIALLY THE SAME
6 4. NO DETERMINATION HAS BEEN MADE BY THIS
I
U_0 OFFICE AS TO COMPLIANCE WITH TOWN
PRECAST LEACHING
1
w ZONING REGULATIONS. OWNER/APPLICANT ISTO OBTAIN
c o BASIN OR EQUIV
r' 24" DIA. COVERS d ° APPROPRIATE S AUTHORITY.UCH DETERMINATION FROM
5. THIS PLAN IS VALID ONLY IF IT IS STAMPED
PLAN VIEW AND SIGNED IN RED. THIS OFFICE ASSUMES
FRAM " NO RESPONSIBILITY FOR INFORMATION CONTAINED
ES & COVERS SHALL O NOT HAVE
gyp, ON COPIES WHICH D
SCS �N"�I BE SET WITH MASONRY UNITS ORIGINAL
STAMPS AND SIGNATURES
WHICH ARE TO BE MORTARED
IN PLACE 6.ALL COMPONENTS OF THE SANITARY SYSTEM
SHALL BE CAPABLE OF WITHSTANDING H-10
INLET06�"MIN.
` .4 :� LEACHING PIT DETAIL LOADING UNLESS THEY ARE UNDER OR WITHIN
t . r:: OUTLET NOT TO SCALE 10 FT. OF DRIVES OR PARKING AREAS. H-20
FLOW LINE —� LOADING (SHALL BE USED UNDER OR WITHIN
�2 MIN REMOVEABLE COVER 10 FT. OF DRIVES OR PARKING AREAS
OUTLET
Y
10"MIN. °: OUTLET TEE PIPES
AS REQUIRED
r `LIQUID DEPTH TEE .DEPTH
BELOW FLOW LINE
4 FT 14 INCHES ° INLET MIN. FRONT SETBACK 7.0
4 FT. MIN. 5 FT. 19 INCHES FLOW ° OUTLET MIN. REAR SETBACK ZO
LIQUID 6 FT. 241NCHES —� v�'�LINE � } —� MIN. SIDE SETBACK,IS
DEPTH 7 FT. 29 INCHES
8 FT. 341NCHES t' 2" sAPPROVED BOARD OF HEALTH
DATE AGENT
°' INLET TEE PROVIDED
PER SECTION 15.10.2
!'77 7 TITLE 5 PROJECT LOCATION:
L_c.TS 7_4 s 2S
NO. OF OUTLETS U�tFTY/COD Lel ARMOUTI3 i R` ^r}A.
CROSS :SECTION VIEW
SEPTIC TANK DETAIL DIST. BOX DETAIL APPLICANT'
NOT TO SCALE NOT TO SCALE C AN;E!
SUL 1yhN
0 MA,W9 �/1/(.
P.11- L`N� I, at�F ,�A: �.%it--_ Stint l t3E • , •
DESIGN CALCULATIONS :cV ��� �� . h' Reg. Land Surveyors — Reg. Sonrlorians
-r-ttlTy 35 ROUTE /34 - UNIT 2 P. O. BOX 237
NUMBER OF BEDROOMS J SOUTH DENNIS, MA.
GARBAGE DISPOSAL UNIT N�' /p��ttDfMq 0
TOTAL ESTIMATED FLOW ,
( Ito GAL/BR./DAYx BR.) `�� GAL./DAY>AMRsi
RtOiARC
REQUIRED SEPTIC TANK CAPACITY �j GAL. p��N § RN 1✓" �t .,
ACTUAL SIZE OF SEPTIC TANK IOU C' GAL. 4F e.S,�y
LEACHING AREA REQUIREMENTS GJSSEP fCtSSEP��� ' {,
So�t!P x• No �;
SIDEWALL AREA GAL./S.F.
BOTTOM AREA 1.G GAL./S.F. ✓' ••....
` l
LEACHING CAPACITY (BOTTOM SIDEWALL) ;4').7 GAL. REVISIONS S -i -P6 Pow
J.14. 1.0 ,c S� + �.1• r; x l.r [ e) SCALE: DATE:
RESERVE LEACHING CAPACITY 54'''.7 GAL. 19s /✓orZ-�D 1-3-86
DR. BY: APPD. BY: r al -i
JOB NO.:
-3117 SHEET 2 OF
FORM II/6/ 85