Loading...
46 Nickerson Farm Way Title 5 Site PlanLEGEND - 99 - EXISTING .CONTOUR X 99.1 EXIST. SPOT ELEV. -[991- PROPOSED CONTOUR (98.4] PROPOSED SPOT EL. TH1 o� "4'YY2; TEST HOLE 1542.8' SLOPE OF GROUND FRONT SETBACK UTILITY POLE Y FIRE HYDRANT NOTE NOT ALL SYMBOLS -MAY APPEAR IN DRAWING *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM PROVIDE MIN. 20" DIAM. WATERTIGHT ACCESS COVERS TO WITHIN 6" OF FIN. GRADE SYSTEM PROFILE (NOT TO SCALE) 2" PEASTONE OR GEOTEXTILE FILTER FABRIC OVER STONE ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. CONCRETE COVERS TO WITHIN 3" GRADE 27, SLOPE REQUIRED OVER SYSTEM NOTE: 2" MIN. WALL PRECAST H-10 BLOCKS OR THICKNESS REQUIRED RISERS (ttPJ PRECAST RISERS 2.0 4"0SCH40 PVC MORTAR ALL H-10 6MINPIPES LEVEL 1ST 2' 4 COMPONENTS " . 12" MIN. SUMP IM. DIM. ENDS (TYP.) !NV'S .. 27.20 4 SIDES 22.0, *24.33' 24.05 TEE 1500 CAL H-10 TEE 23.80' ��®® ®®®® ®®�® -�®®® ° SEPTIC TANK ' o00o m®mmmmmmmmm mmmmmm®mmmrJ 4' LIQ. LEVEL 000n ° ° WATERTEST D'BOX mmm®❑�❑��®O®O.O ACME OR EQUAL CAS BAFFLE FOR LEVELNESS N i°°o°°o°°o°°o m m®®m m®mmm m m m ®®m m®mm®® 21.47' 21.30' °° gpa00000 19.2 °000Q000000OQ0000000QOOOO000000000aooQ000000` '.,000,°,ororo�o�o� oo°"o ror"r°ro„o"o�00000° 3�4"-1-1�2" DOUBLE WASHED STONE 4' MIN. H-10 500 GAL LEACHING CHAMBER BY ACME PRECAST OR EQUAL uooe �- -ALL AROUND PRECAST STRUCTURES - (3) UNITS REQUIRED 6" CRUSHED STONE OR MECHANICAL OVERALL DIMENSIONS TO OUTSIDE OF STONE: 33.50' X 12.83' COMPACTION. (15.221 (2]) c ( 2'5% SLOPE) FOUNDATION- 11' - SEPTIC TANK (_L6_% SLOPE) - 65' - D' BOX (-L-% SLOPE) 12' DICE #16-057 -1- Lc0-\(, DATE LEACHING FACILITY NOTES 13.0' BOTTOM TH-2LOCUS MAP NO GROUNDWATER FOUND SCALE 1"=20OD't ASSESSORS MAP 118 PARCEL 23.3 LOCUS IS WITHIN FEMA FLOOD ZONE X (AREA OF MINIMAL FLOOD HAZARD) AS SHOWN ON COMMUNITY PANEL #25001CO579J DATED 7/16/2014 1. DATUM IS NAVD 88 2. MUNICIPAL WATER IS PROPOSED 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-12 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-868-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. 12. DRYWELLS ARE PROPOSED FOR ROOF RUN-OFF. APPROXIMATE LOCATION SHOWN. Tn Q 14 O O LU co T) Co DO n 6d ZONING SUMMARY ZONING DISTRICT: R-40 DISTRICT d PROPOSED lI I � 40,000 S.F. Follins o� LOT FRONTAGE Pond 1542.8' MIN. FRONT SETBACK OG 30.7' MIN. SIDE SETBACK 20' 66.5' MIN. Stoney Hill R\oo � o 20' 20.9' Locus oSe TPS o Q N 25% I O n BUILDING HEIGHT 35' <35' Knob HiJI R Whites Poth BW c 13.0' BOTTOM TH-2LOCUS MAP NO GROUNDWATER FOUND SCALE 1"=20OD't ASSESSORS MAP 118 PARCEL 23.3 LOCUS IS WITHIN FEMA FLOOD ZONE X (AREA OF MINIMAL FLOOD HAZARD) AS SHOWN ON COMMUNITY PANEL #25001CO579J DATED 7/16/2014 1. DATUM IS NAVD 88 2. MUNICIPAL WATER IS PROPOSED 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-12 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-868-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. 12. DRYWELLS ARE PROPOSED FOR ROOF RUN-OFF. APPROXIMATE LOCATION SHOWN. Tn Q 14 O O LU co T) Co DO n 6d ZONING SUMMARY ZONING DISTRICT: R-40 DISTRICT PROPOSED MIN. LOT SIZE 40,000 S.F. 59,312 SF MIN. LOT FRONTAGE 150' 1542.8' MIN. FRONT SETBACK 30' 30.7' MIN. SIDE SETBACK 20' 66.5' MIN. REAR SETBACK 20' 20.9' MAX. BUILDING COVERAGE 25% 9.1% MAX. BUILDING HEIGHT 35' <35' SITE IS LOCATED WITHIN THE AQUIFER PROTECTION OVERLAY DISTRICT REFERENCES DEED BOOK 16070 PAGE 243 PLAN BOOK 584 PAGE 96 SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED PROPOSED 4 BEDROOM DWELLING DESIGN FLOW: 4 BEDROOMS @ 110 GPD = 440 GPD USE A 440 GPD DESIGN FLOW SEPTIC TANK: 440 GPD (2) = 880 USE A 1500 GAL. SEPTIC TANK LEACHING: SIDES: 2(33.5 + 12.83) 2 (.74) = 137 GPD BOTTOM 33.5 x 12.83 (.74) = 318 GPD TOTAL: 615 S. F. 455 GPD USE (3) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH 4' STONE ALL AROUND APPROVED DATE BOARD OF HEALTH TEST HOLE LOGS ENGINEER: CRAIG J. FERRARI, SE #13871 WITNESS: AMY VON HONE, RS DATE: 3/9/2016 PERC. RATE = < 5 MIN/INCH CLASS ISOILS Q ELEV. > 0" 26' A LS 7" 1OYR 3/1 B LS 1OYR 5/4 22" 24.2' C PERC LMS 2.5Y 7/4 4 ELEV. 0" 2 25' - 0/A - LS 10YR 3/1 3" C1 LMS 1OYR 5/4 72" 19' C2 MS 2.5Y 7/4 144" 1 J 14' 144" 1 NO GROUNDWATER ENCOUNTERED OF 13' , MA #46 NICKERSON FARM WAY Yarmouth Health Department Date DANIEL A. OJALA, P.E., P.L.S. (SOUTH) YARMOUTH PREPARED FOR ALIAKSEI KUHARENKA APRIL 20, 2016 Scale:1"= 20' 0 10 20 30 40 50 FEET I off508-362-4541 fax 508-362-9880 downcape.com down cape engineering, inc, civil engineers land surveyors 939 Moin Street ( Rte 6A) YARMOUTHPORT MA 02675 16-057