HomeMy WebLinkAbout83-820 - Site PlanSlakes angled into ground P110Ale Hay Balls Double Row —Roof Drains to dry wells. All Driveways hove been calculated to drain to streets and street drain system. See ca%ulations for Subdivision and Planning Board Filing Soil Tests made for Septic System Permit Procedures in front Lot in Area of Proposed System on June /71h 1987 showed the soil to be O N 30" Loam 8 "Subsoil" 30"- 144" Clean Coarse Sand. No water encounted Percolation Rate Less than 2min/inch v 1 a/ 1 L 1 1 (40 W10F) [i V V C (PRIVATE) /` UAV NOTE: THIS STRUCTURE IS "7FT•l' UPHILL FROM THE So' LINE SEPTIC -TANK DETAIL T NOTO SCALE NOTES tI SEPTIC TANK SHALL BE REINFORCED CONCRETE. 2 SEPTIC TANK TO WITHSTAND H-10 LOADING UNLESS UNDER PAVEMENT, DRIVES OR TRAVELED WAYS,WHEREIN H-20 LOADING SHALL APPLY. 3 ALL RPE CONNECTIONS AND CONCRETE CONSTRUCTION TO BE WATERTIGHT 77 4 INLET AND OUTLET TEES TO BE CAST IRON OR SCHED 40 PVC TO BE CENTERED UNDER MANHOLE COVER 5 1000 GAL. TANK SHOWN OR ANY OF EQUAL CAPACITY APPROVED MANHOLE, COVER WITHIN 12' FINISH GRADE -i �- -- - -- -- --- ---T 15"T'— 1'7 r, 1 I INLET TEE I _ PRSEIC ECAST. 4'6" LIQUID DEPTH Ta FLET ;. 1 — TAMC —... 516.. I. I , BOTTOM ON LEVEL STABLE BASE PLAN VIEW '✓I" CROSS-SECTION VIEW LEACHING PIT DETAIL NOT TO SCALE MANHOLE COVER LOAM 8SEED WITHIN 12" OF FINISH 2°MIN OF 1/811 „ TO 1/2" - I?'1MIN FILL WASHED STONE .+t:':f;: • .o> PVC INLET PIPE C C3 0 0 0 0 o v v C) o. `.0'� •e NOTE a 3 O O 0 0 o �. • °cl) ° LEACHING PIT TO Dob ❑ o 0 0 0 0 o a o 0o WITHSTAND H-10 LOADING o ;0 r(L F UNLESS UNDER PRECAST ( - D y PAVEMENT,DRIVE OR w 3/4'1 TO I-1/2'1 0 O CD 0 0 0 0 0 0 TRAVELED WAY WHEREIN o H-20 LOADING SHALL F 6 DOUBLE LEACHING PIT �+ °°0 APPLY v WASHED .• 0 0 o v o M m 0 0 , STONE 7.0 lnot.nes w ❑ M o 0 0 0 0 o 0 o D - e' 8glr ��o ¢°•a o v a v v o 0 0 6" MIN. 2'0" 6'5 "DIA. 2' O" • 10' 5"DIA. CROSS - SECTION DESIGN CRITERIA DESIGN FLOW 4 BR x 110 GCI./ 8R - 440 G0I100Y REQUIRED SEPTIC TANK 440 x 1.5 = 660 GAL SEPTIC TANK PROVIDED = 1000 GAL. SIZE OF LEACHING FACILITY REQUIRED DESIGN PERC. RATE 2 MIN./INCH Laach l�Q PiiS 2-6' deep t0 ST ICrneter SIZE OF LEACHING FACILITY PROVIDED 2 Pits cit to 5' dlarneter x 6' deep 0 Expansion Pit ICATES OBSERVED W DI6ATE! L ecching Pit 0 Tank -5'x 8' C. B Catch Basin ----/00' Line ----x-50Line —30 Line ---- Top of Bank DB Distribution Box 67 SOIL TEST PIT DATA TP GRD. EL. GW EL - Te.. SgRd No Wako DATE TEST BY WITNESSED BY PERC RATE MIN/INCH TP GRD. EL rw FI INDICATE! PERK .,�- — ICATES OBSERVED W DI6ATE! TEST aflO VND WATER TP TP GRD EL GRD EL rw Fl DATE DATE TEST TEST BY WITNESSED BY WITNESSED BY PERC RATE PERC RATE MIN/INCH -MIN /INCH b w. L -1— DAT E TEST BY WITNESSED BY PERC RATE MIN /1`JCH