HomeMy WebLinkAboutEngineered Plan - Rev. 2016WASHED STONE X. A „ 100.0 MAX. OR FILTER FABRIC VENT 2.50' 4" CAST IRON PIPE MAX. 97.75 MSN. NOT REQUIRED (OR EQUAL) MINIMUM PITCH 1/4" PER FT. FLOW - TEE ., Z LEVELERS DEPTH HORIZ TEXTURE . SOS L TEST TOP OF FOUNDATION AP 20 FT. MINIMUM FROM . CELLAR OR CRAWL SPACE 10YR5/1 . NO ROOTS 12-22" 'B DATE OF SOIL TEST JUNE_9 _2016__x_ ' 100.tJ0 ELEV. _ _0 10 FT. MINIMUM 10 FT.. MINIMUM FROM SLAB C CLEAN SAND SOIL TEST WITNES ED DONE yQN HONE (ASSUMED) CONCRETE INSPECTION . COVERS ry 4 SCHEDULE 40 PVC PIPE MIN. PITCH 1/8' PER FT. .PORT LOAM AND SEED " _ 2 LAYER OF 1/8t, TO 1/2" � OSEf'` VA�ON I--li�ii.>i� 1 ELEV.=- 100-0 PERCOLATION , RATE < 2 MIN./INCH AT 50 INCHES . WASHED STONE X. A „ 100.0 MAX. OR FILTER FABRIC VENT 2.50' 4" CAST IRON PIPE MAX. 97.75 MSN. NOT REQUIRED (OR EQUAL) MINIMUM PITCH 1/4" PER FT. FLOW - TEE ., Z LEVELERS DEPTH HORIZ TEXTURE . COLOR MOTT. OTHER • 0-12" AP LOAMY SAND 10YR5/1 . NO ROOTS 12-22" 'B LOAMY SAND 10YR6/6 22-150" C MEDIUM SAND 2.5Y7/4 FLOW LINE 97.0 rn NO WATER ENCOUNTERED AT 150" ELEV. = 87.5 _ 0 ELEV. 97.50 10 MIN. o 0 INTERIOR PIPING IS TO 96.95 2,0. =_ ° • o DES�G6 CALCULATIONS liii�BS BE RAISED (BY A LICENSED ELEV, ____� _ 95.67 6" SUMP LEVEL >�6.50 0 ° c 0 10 ELEV. _ ES1GL1 AS 3 IF NECESSARY V. _ . 97.20 GAS = 96,6 ELEV. _ __�__ - __ _ �'° _ NUMBER OF BEDROOMS PLUMBER) ELEV. --- ELEV. �__� 7 r 2 BAFFLE GARBAGE DISPOSAL UNIT . _ DISTRIBUTION ELEV, ESTIMATED FLOW, ELEV. 4 HIGH CAPACITY INFILTRATORS, WITH LIQUID OUTLET ^ __2&5!2__/STONE IN AN ( 110 GAL./BR./DAY X 3 ER `_ � GAL./DAY. ' BOX, DEPTH TEE(T0 BE PLACED ON FIRM BASE) Z _ REQUIRED SEPTIC -TANK CAPACITY `15 4 FEET 14 INCHES TO BE WATER TESTED '_ GAL. 5 FEET 19 INCHES. IF MORE THAN ONE OUTLET 11� X 36� X 10" TRENCH FORMATION B.17 ACTUAL SIZE OF SEPTIC TANK 1300 GAL. 1 6 FEET 24 INCHES 1500 GAL.LO `� . / 1n SOIL CLASSIFICATION �1 �®®��++n �' WELL N A DESIGN PERCOLATION RATE <�� MIN./IN. 7 FEET 29 INCHES �. (Td BE PLACED ON FIRM BASE) SOIL ABSO 'RPTION. �1 i , 8 FEET 34 INCHES SEPTIC T���� ZONE i EFFLUENT LOADING RATE --QJA- .GAL./DAY/S.F. 3/4" TO 1 1 /2" CLEANr ) INDEX LEACHING AREA 474.33 SQ. - FT. DOUBLE WASHED STONE SYS i �.� ISS ADJUST (11X35)+(47X2X10/12) FREE OF FINES & .SILT LEACHING CAPACITY (AREA X RATE) MUM GAL./DAY 4. 4 74 7.33X0. t +o A c - USGS PROBABLE WATER TABLE ELEV..= __,.... ' SEWAGE DISPOSAL SYSTEM, PRO ILL OBSERVED WATER TABLE ( / / ) ELEV. _ _�N� RESERVE LEACHING CAPACITY _��'� GAL./DAY NOT TO SCALE BOTTOM OF TEST HOLE ELEV. _ $M�12_ . - N O OTES 1.ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO D.E.P. -TITLE 5 AND THE TOWN'S RULES AND REGULATIONS FOR THE SUBSURFACE DISPOSAL OF SEWAGE, 2. ALL COVERS TO SANITARY UNITS SHALL BE BROUGHT TO WITHIN 6" OF FINISHED GRADE 3. ALL COMPONENTS OF THE SANITARY SYSTEM .SHALL BE CAPABLE OF WITHSTANDING H-10 LOADING UNLESS THEY ARE UNDER OR WITHIN 10 FT. OF DRIVES OR, PARKING AREAS H 20 LOADING SHALL BE 00.5 \ R UNITS E SHALL USED UNDER O N 10 FT. -OF -DRIVES OR PARKING 4. ANY MA50NARY USED TO BRING COVERS TO GRAD . - 8E MORTARED 1N PLACE. `. 5. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE Vt%7f-i \ DEEDED OR ZONING REGULATIONS- OWNER / APPLICANT.'IS TO OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY. UTILITIES SHOWN ARE APPROXIMATE ONLY, EXCAVATION CONTRACTOR IS TO CALL "DIG -SAFE" AT 1-888-344-7233 AT LEAST 72 HOURS PRIOR TO COMMENCING WORK ON SITE 98.1 �O 7.CONTRACTOR 1 . S TO VERIFY GRADES AND ELEVATIONS AS WELL' AS ORKLON ANY x �0� 99.8 0 � ,. S�OCONDITIONS BROUGHTPRIOR0 THE ATTENTION COMMENCING OF .THE DESIGN SITE. TION ENGINEEP.RIA 99.4 �. \ IMMEDIATELY. . s 100,2- " . 8: PARCEL IS. IN FLOOD ZONE <. 100 -9' LOT IS SHOWN ON 3 99 3 S hX AS 'PA�tCEL --11-- 140.3 ,. �,� � � - . -- 10. EXISTING CESSPOOLS SARESTO BE PUMPED AND. REMOVED ALONG WITH ANY POLLUTED SOILS ENCOUNTERED. . I 100.3 100.5 x 98.8 97.0 99.8 \ 99.2 SOIL x TEST P .5 8 D , P2 96.4 r.;/T��� .� < y ..� Ya>I•a�a®>l�th He�Ith Department BOX --100 99.$ �� 1 ce x 96.1 r % a o � / t1°Ie Date a ka. til 0 I E v , 1 00 99.1 4: `�v 70 Ci .. a x ! f O � 4a. � ,1. 1500 GALLON h 98.0 p w O y APPROVED: BOARD 01 H -E L tH SEPTIC TANK 99.5 r� y: 00 n oo z ,,, „ 1 DATE AGENT