Engineered Plans - 2016LOCUS DATA CURRENT OWNER MILLER FAMILY IRREVOCABLE TR. PLAN REFERENCE LCP 31209—D CTF. REFERENCE LC 196432 Z ZONING DISTRICT R-40 FLOOD ZONE "X" ASSESSORS MAP 99 PARCEL 65 OVERLAY DISTRICT ZONE II LOT AREA 11,495± S.F. SITE & SEWAGE REPAIR PLAN #172 DIANE A VE IN YARMOUTH, MASS DATE: JUNE 20, 2016 OWNER/APPLICANT: JOHN & JANE MILLER 172 DIANE AVE &YARMOUTH, MA 02664 (508) 394-1772 SHEET 1 OF 2 PREPARED BY: EAS SURVEY, INC. P.O. BOX 1729 SANDWICH, MA 02563 PH. (508) 888-3619 CELL (508) 527-3600 EAS. SU R VEY@YAH 00. COM LOT 100 5" 1p538, N414 0 42.0 X 17.7' -42.4 X i i 41.7 DRIVEWAY W LOT 99 \ Ln 0 11,495± S.F. 42.6 \ o - D \\ C \ rn \ z �C 40.3 C \ GARAGE 9 ANING AREA G KII #172 42.2 N PROPOSED 10'x29' 1�- LEACHING AREA 0 LOCUS MAP ` NOT TO SCALE: 16-0116 42.5 10,EXISTING SEPTIC SYSTEM COMPONENTS TO BE PUMPED, CRUSHED AND REMOVED FROM 10ift SITE IN ACCORDANCE WITH TITLE 5. k 18" PINE TO REMAIN LNDY. HALL L. BATH BED#1 N CONCRETE BOUND FOUND & HELD cn D. T. #1 N 42.4 'ACL X 42.3 11'42.4 41. 0.2' N os PROPOSED 1.500 GALLON 02 r" SEPTIC TANK C.O. �. 42.2 X 42.4 ��, 0 G X 42.4 42.8' o -w_-� 20.3' AV Yarmouth Health Department ZZ 4 1p5 95 „ W 1.6 ,� PP VED j FE NCE S 77'1J 34 BENCHMARK Name Ute TOP OF CONCRETE BULKHEAD. ELEV=43.00 LOT 98 0 20 30 40 GRAPHIC SCALE: 1 INCH = 20 FEET OF FOUNDATION 43.00 OUT INV.= ' 39.85 2. 5-7" 4'-6 1/2 (�A INV.= 41.25 36.0' OS=0.04 ® INV.= 40.50 15.0' OS=0.04 - , - L JOB # 16-0116 SITE & SEWAGE REPAIR PLAN #172 DIA NE A VE IN YARMOUTH, MASS DATE: JUNE 20, 2016 SE COVERS TO WITHIN 6" OF FINISH GRADE FINISH GRADE FINISH GRADE ELEV. 42.1 ELEV. 42.2 ELEV. 42.4 = 402 CENTER CHAMBER RISER RAISE TO WITHIN 6" OF FINISH GRADE 42.2 MIN. -3' MAX. COVER 36'OS=0.025 ivr c�cv JJ.JV 2 MIN 3 MAX 4" PVC SCH 40 4' ®S= 0.02 00000 0 o 00000 o 10"TEE 14"TEE INV.= 0 000 0 0 0 0020 00000 M 39.65 INSTALL 6" OOpOp o 0 00000 GAS BAFFLE 3 OUTLET 4'-1" LIQUID LEVEL H-20 DB3 TWO 5' -0"x8' -6"x3'-0" CHAMBERS INV.= 38.75 S.A.S. (10.0' x 29.0') o ci INV.=38.58 a ul C e e o BOT 35.30 INV.= 38.50 �- 6" BASE OF CRUSHED STONE OR MECHANICALLY COMPACTED 1,500 GALLON PRECAST CONCRETE SEPTIC TANK OWNER/APPLICANT: JOHN & JANE MILLER 172 DIANE AVE S.YARMOUTH, MA 02664 (508) 394-1772 SHEET 2 OF 2 PREPARED BY: EAS SURVEY, INC. P.O. BOX 1729 SANDWICH, MA 02563 PH. (508) 888-3619 CELL (508) 527-3600 EAS. SU R VEY@YAH 00. COM CONSTRUCTION NOTES: 1. CONTRACTORS / INSTALLERS SHALL VERIFY GRADES AND ELEVATIONS AND SITE CONDITIONS PRIOR TO COMMENCING WORK ON THE SITE. 2. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEEDED OR ZONING REGULATIONS. OWNER / APPLICANT IS TO OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY. 3. ENGINEER TO VERIFY REMOVAL OF UNSUITABLE SOILS PRIOR TO INSTALLATION OF NEW SEPTIC SYSTEM. 4. NO PARKING OVER SEPTIC TANK IS ALLOWED. GENERAL NOTES: 1. ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO D.E.P. TITLE V AND THE TOWN OF YARMOUTH RULES AND REGULATIONS FOR SUBSURFACE DISPOSAL OF SEWERAGE. 2. AT LEAST ONE ACCESS POINT OVER TANK TEES SHALL BE ACCESSIBLE WITHIN 3" OF FINISH GRADE, WITH ANY REMAINING ACCESS PORTS BROUGHT TO WITHIN 12" OF FINISH GRADE. 3. ALL COMPONENTS OF THE SANITARY SYSTEM SHALL BE CAPABLE OF WITHSTANDING H-10 LOADING UNLESS OTHERWISE SPECIFIED. 4. THE EXCAVATION CONTRACTOR SHALL VERIFY THE LOCATION OF ALL UTILITIES PRIOR TO ANY EXCAVATION. 5. ANY MASONRY UNITS USED TO BRING COVERS TO GRADE OR WITHIN 6" OF GRADE SHALL BE MORTARED IN PLACE. 6. FINISH GRADE SHALL HAVE A MINIMUM OF 0.02 FEET PER FOOT OVER THE S.A.S. AND DISTRIBUTION BOX. 7. SEPTIC TANK SANITARY TEE'S SHALL BE CONSTRUCTED OF SCHEDULE 40 PVC AND SHALL EXTEND A MINIMUM OF 6" ABOVE THE FLOW LINE AND SHALL BE ON THE CENTERLINE AND LOCATED DIRECTLY UNDER THE CLEAN OUT MANHOLES. 8. THE INLET PIPE INVERT ELEVATION SHALL BE NO LESS THAN 2 INCHES NOR MORE THAN 3 INCHES ABOVE THE INVERT ELEVATION OF THE OUTLET PIPE. 9. THE SEPTIC TANK SHALL HAVE A MINIMUM COVER OF 9 INCHES 10. THE OUTLET SANITARY TEE SHALL BE EQUIPPED WITH A GAS BAFFLE, 4 INCHES IN DIAMETER AND CONSTRUCTED OF 4" PVC 11. ALL PIPES SHALL BE SCHEDULE 40 PVC SEWER PIPE AND SHALL BE SLOPED 1/4 INCH PER FOOT MIN. EXCEPT FOR THE FIRST TWO FEET OUT OF THE DISTRIBUTION BOX WHICH SHALL BE LEVEL 12. CHANGES OR REVISIONS TO SEPTIC DESIGN REQUIRE NOTIFICATION TO EAS SURVEY INC. FOR B.O.H. AND DESIGN ENGINEERS REVIEW AND APPROVAL. 13. MAGNETIC TAPE ON ALL COMPONENTS. 36.50 32.4 ••••• ••••• --- 2.5' 5.0' -- �-- 2.5'----1 10.0' --I SIDE VIEW DATUM: VERTICAL DATUM: YARMOUTH GIS± BENCH MARK USED: TOP OF CONCRETE BULKHEAD ELEVATION 43.00 DTH #1 INDICATES DEEP TEST HOLE SYSTEM DESIGN DESIGN FLOW 2 BEDROOMS AT 110 GPB/D 22-0 GPD REQUIRED SEPTIC TANK 220 x_2__ _ _____440 GAL. SEPTIC TANK PROVIDED = _ 15Q0_GAL. SIZE OF LEACHING FACILITY REQUIRED DESIGN PERC RATE ---!2-----MIN./INCH LONG TERM APPL. RATE_2•74_GPD/S.F. SIZE OF LEACHING SYSTEM PROVIDED: 220 + 0.74 SF/GPD = 298 S.F. MIN. REQ. USING H-20 CONCRETE LEACHING CHAMBERS WITH 4' OF STONE AT ENDS AND 2.5' OF STONE ON SIDES. BOTTOM (10.0' x 29.0') = 290 S.F. SIDE WALL (10.0' + 29.0') 2x2 = 156 S.F 446 S.F. 446 S.F.x 0.74 G/SF = 330 GPD 330 GPD PROV > 220 GPD REQ.= 110 GPD RES. NO (GARBAGE DISPOSAL / GRINDER ALLOWED) D.T.H. #1 > DATE: 6/8/16 GROUND ELEV. 42.4 ADJ. G.WATER 31.4 -oo- 120" INDICATES ADJ. GROUNDWATER ==:bl NO OBSERVED GROUNDWATER INDICATES PERC TEST GROUNDWATER ADJUSTMENT DEPTH TO BOTTOM OF HOLE 10.0' _VARIANCES REQUESTED TITLE V: NONE RESTRICTIONS 2 BEDROOM DEED RESTRICTION REQUIRED TO BE RECORDED AT THE BARNSTABLE REGISTRY OF DEEDS. LOAMY SAND 1OYR 4/2 10YR 5/1 12„ B LOAMY SAND 1 QYR 5Z5 11 26" .i FV = 4n9 C-1 44„ FINE SAND 10YR 7/6 72" C-2 FINE SAND 2.5Y 7/4 NO G.WATER 1120„ ELEV = 32.4 B.O.H. AMY VON HONE SOIL EVALUATOR ED. STONE BACKHOE OPERATOR. LARRY - ELLIS BROTHERS SOIL TYPE: --_ PERC RATE: <4 MIN. PER INCH LOADING RATE: 0_74 GAL/SF/MIN