HomeMy WebLinkAboutEngineered Plans - 2016t
T13M = EL. 29.7 '
BULKHEAD FOUND.
25.1
Q 27
OP
27.5 C
�7
�0---0028 � 7 �C
O
2G p6 \ /G "TO
�o
J
SFS, 29.2 606, EXIST. 1,00�0G
�q cF SEPTIC TANK I
25.2 ,�
I S��
28.8 %'1-0
0 \ i
X96,
28.
FLOOR PLAN
SCALE: 1 "=20 j
lgsi"
\ \ /°-qT pp \ GENERAL NOTES: \ / 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL
BOARD OF HEALTH AND THE DESIGN ENGINEER.
2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS
OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE
LOCAL RULES AND REGULATIONS.
3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR
TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE
X44 66� 25.9 �_ DESIGN ENGINEER.
/ 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING
FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN
ENGINEER BEFORE CONSTRUCTION CONTINUES.
5. ALL ELEVATIONS BASED ON ASSUMED DATUM.
25—
all,
Yarmouth Health Department
APP VED
*ime Date
SURVEY BY: WELLER AND ASSOC.
6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF
THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF
HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION.
7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE.
8. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED
TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR.
9. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE
THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING
CONSTRUCTION.
10. EXISTING LEACHING TO BE PUMPED, CRUSHED AND FILLED PER TITLE 5.
11. 48 HOUR NOTICE FOR ENGINEER CERTIFICATION
12. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY
AND IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY
13. NO PRIVATE WELLS WITHIN 150' OF PROPOSED LEACHING.
14. NO WETLANDS WITHIN 100' OF PROPOSED LEACHING.
15. ALL PIPING TO BE 4" SCH 40 O 1/8"/FT (UNLESS SPECIFIED)
16. SOLIDS UNE TO BE SLEEVED, 10 FT EITHER SIDE OF WATER LINE.
SOUTH YA
JUN,=, r
HEALTH
QI
GP gP
Cgpr GPQ'�• RSON RD
N,CKE
CAp�. SMALL Rp.
LOCUS
LOCUS MAP
LOCUS INFORMATION
TITLE REF: BK 22172 PG 163
PARCEL ID: MAP 078 PAR. 090
SEPTIC SYSTEM
REPAIR PLAN
LOCATED AT:
55 CAPTAIN NICKERSON RD
SOUTH YARMOUTH, MA
PREPARED FOR
JAMES HENRY
JUNE 3, 2016
�N OF
No: 11
S�� ;
MEYER & SONS, INC.
P.O. BOX 981
EAST SANDWICH, MA. 02537
PH: (508)360-3311
FAX: (774)413-9468
meyerandsonstitle5@gmail.com
www.meyerandsons.com
SHEET 1 OF 2 J#1744
LEGEND
PROPOSED CONTOUR
Um
PROPOSED SPOT GRADE
--98--
EXISTING CONTOUR
+ 96.52
EXISTING SPOT GRADE
W—
EXISTING WATER SERVICE
TEST PIT
2G p6 \ /G "TO
�o
J
SFS, 29.2 606, EXIST. 1,00�0G
�q cF SEPTIC TANK I
25.2 ,�
I S��
28.8 %'1-0
0 \ i
X96,
28.
FLOOR PLAN
SCALE: 1 "=20 j
lgsi"
\ \ /°-qT pp \ GENERAL NOTES: \ / 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL
BOARD OF HEALTH AND THE DESIGN ENGINEER.
2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS
OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE
LOCAL RULES AND REGULATIONS.
3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR
TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE
X44 66� 25.9 �_ DESIGN ENGINEER.
/ 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING
FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN
ENGINEER BEFORE CONSTRUCTION CONTINUES.
5. ALL ELEVATIONS BASED ON ASSUMED DATUM.
25—
all,
Yarmouth Health Department
APP VED
*ime Date
SURVEY BY: WELLER AND ASSOC.
6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF
THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF
HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION.
7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE.
8. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED
TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR.
9. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE
THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING
CONSTRUCTION.
10. EXISTING LEACHING TO BE PUMPED, CRUSHED AND FILLED PER TITLE 5.
11. 48 HOUR NOTICE FOR ENGINEER CERTIFICATION
12. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY
AND IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY
13. NO PRIVATE WELLS WITHIN 150' OF PROPOSED LEACHING.
14. NO WETLANDS WITHIN 100' OF PROPOSED LEACHING.
15. ALL PIPING TO BE 4" SCH 40 O 1/8"/FT (UNLESS SPECIFIED)
16. SOLIDS UNE TO BE SLEEVED, 10 FT EITHER SIDE OF WATER LINE.
SOUTH YA
JUN,=, r
HEALTH
QI
GP gP
Cgpr GPQ'�• RSON RD
N,CKE
CAp�. SMALL Rp.
LOCUS
LOCUS MAP
LOCUS INFORMATION
TITLE REF: BK 22172 PG 163
PARCEL ID: MAP 078 PAR. 090
SEPTIC SYSTEM
REPAIR PLAN
LOCATED AT:
55 CAPTAIN NICKERSON RD
SOUTH YARMOUTH, MA
PREPARED FOR
JAMES HENRY
JUNE 3, 2016
�N OF
No: 11
S�� ;
MEYER & SONS, INC.
P.O. BOX 981
EAST SANDWICH, MA. 02537
PH: (508)360-3311
FAX: (774)413-9468
meyerandsonstitle5@gmail.com
www.meyerandsons.com
SHEET 1 OF 2 J#1744
tf
ELEV. TOP NOTE: MAGNETIC TAPE TO BE PLACED OVER ALL COVERS
FOUNDATION
(Existing) SEPTIC TANK PROPOSED D -BOX
= 30.0 INSTALL RISERS & COVERS OVER INLET & INSTALL RISER & COVER
OUTLET AND SET TO 6" OF FINISH GRADE SET TO 6" OF GRADE
F.G.EL: 29.0 F.G. EL.=28.30± F.G. EL: 26.50±
9" MIN COVER/
36" MAX COVER L = 115' L = 1O'(MAX)
0 S=1% (MIN.) EL= 27.30 ® S=1% (MIN.) 0 S=1% (MIN.)
4"SCH40 4"SCH40 PVC 4"SCH40 PVC
loll 6
INV.=26.25 14"
48" LIQUID INV.=26.0
LEVa
PROPOSED
GAS
D -BOX
INV.=24.0 DB -
EXIST. 1.000 GALLON SEPTIC TANK (H2O
EXIST. SEWER OUTLET (FRONT TANK)
/-F.G. EL.=28.50±
9" MIN COVER/
36" MAX COVER
EL.= 26.85
,.,....•.•. :.. - ; OUT TO D -BOX
10" SHOWN ABOVE
\NV.=25.82 14'48" LIQUID
LEVEL BAFFINV.=25.57
I GAS LE
I PROP, 1.500 GALLON SEPTIC TANK
EXIST. SEWER OUTLET (REAR TANK) SEPTIC
EL- 26.18
DESIGN CRITERIA
11.3" TO
INVERT
INV.=22.61 -
=23.80
NOTE: TO PREVENT BREAKOUT, THE PROPOSED
FINISH GRADE SHALL NOT BE < EL: 23.0
FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE S.A.S.
PR POS S.A.S.
INSTALL A 4" DIAMETER INSPECTION PORT OVER
ONE CHAMBER (MIN.) AND SET TO 3" OF F.G.
/-F.G. EL: 26.0-25.5(MAX.)
INSTALL TWO INSPECTION PORTS (MIN.)
4 ROWS OF 4 UNITS AT 6.25'/UNIT = 25'/ROW
SOIL ABSORPTION SYSTEM (PROFILEI
NOTES: 1) CONTRACTOR SHALL VERIFY ALL EXISTING
PIPE INVERTS PRIOR TO CONSTRUCTION
2) TANK/D-BOX SHALL BE SET LEVEL AND TRUE TO
GRADE ON A MECHANICALLY COMPACTED SIX
INCH CRUSHED STONE BASE, AS SPECIFIED IN
310 CMR 15.221(2)
3) REPLACE EXISTING 1,000 GALLON SEPTIC TANK
WITH 1500 GALLON SEPTIC TANK IF FAILED,
DAMAGED, NOT H2O LOADING, OR UNDERSIZED.
4) INSTALL INLET & OUTLET TEES W/
GAS BAFFLE AS REQUIRED
SYSTEM PROFILE
T
NUMBER OF BEDROOMS: 3 BEDROOM DESIGN
DESIGN FLOW: RESIDENTIAL: 3 BEDROOMS 0 110 GPD/BR = 330 GPD
DESIGN PERCOLATION RATE: <2 MIN/IN SOIL TEXTURAL CLASS: CLASS 1 (0.74 GPD/SF)
GARBAGE GRINDER: NO (not designed for garbage grinder)
DISTRIBUTION BOX: USE DB -5 (H20)
SEPTIC TANK: FRONT: 330 gpd x 200% = 660 gpd USE EXIST. 1,000G SEPTIC TANK
REAR: 330 gpd x 200% = 660 gpd USE NEW 1,500G SEPTIC TANK
LEACHING AREA REQUIRED: (330)/.74 = 445.94 S.F.
PRIMARY S.A.S.
USE 4 ROWS OF 4 - HI -CAP INFILTRATOR H-20 UNITS -NO STONE
BOTTOM AREA: (GENERAL USE APPROVAL FOR 4.73 SF/LF OF CHAMBER)
(CHAMBER) 16 UNITS x 6.25 LF x 4.73 SF/LF = 473.0 SF
TOTAL AREA = 473 SF
DESIGN FLOW PROVIDED: 0.74GPD/SF(473SF) = 350 GPD > 330 GPD req'd
BREAKOUT=TOP ELEV.=23.00
INV. ELEV.= 22.61
BOTTOM ELEV.= 21.66
2.83'
RESTORE VEGETATIVE COVER
BACKFILL WITH CLEAN PERC SAND
AND COMPACT THE 18" OF MATERIAL
ABOVE CHAMBERS FOR H2O LOADING
i
EXISTING SUITABLE
MATERIAL
5' MIN. ABOVE BOTTOM OF-
T.P. EXCAVATION OR G.W. EFFECTIVE WIDTH = 4 x 2.83' = 11.32'
(6.46' PROVIDED) USE 4 ROWS OF 4 -HIGH CAPACITY
BOTTOM OF TESTHOLE: EL: 15.20 = INFILTRATOR (H20) UNITS W/ ENDCAP-NO STONE
SOIL LOGS
DATE: MAY 18, 2016
SOIL EVALUATOR: DARREN M. MEYER, RS, CSE 1614
WITNESS: PHIL RENAUD, YARMOUTH HEALTH
Elev.
TP- 1
Depth
26.20
0"
A
LOAMY SAND
10YR 3/1
26.38
10"
B
LOAMY SAND
tOYR 5/8
23.20
C
36"
PERC 0
MEDIUM SAND
EL. 22.0
2.5Y 7/4
15.20
132"
PERC RATE <2 MIN/IN. ("C" HORIZON) ASSUMED
NO GROUNDWATER OBSERVED
• I, Darren M. Meyer, R.S., CSE, hereby certify that I am currently approved by MADEP pursuant to 310 CMR 15.017
to conduct soil evaluations and that the above analysis hos been performed by me consistent with the
requirements of 310 CMR 15.017. 1 further certify that I have passed the Soil Evol. Exam in October, 1999.
TYPICAL SECTION
N.T.S.
SECTION
11"
INVERT
HEIGHT END CAP
INFILTRATOR - HI CAPACITY (H20) CHAMBER
PROPOSED SEPTIC SYSTEM UPGRADE PLAN
55 CAPTAIN NICKERSON ROAD, SO. YARMOUTH, MA
Prepared for: Henry
System Design and Site Plan by: SCALE DRAWN DATE
MEYER & SONS, INC. N.T.S. DMM
PO BOX 961
EASTSANDWICH, MA 02537 DATE CHECKED SHEET NO.
508,62-2922 06/03/16 DMM 2 of 2