Loading...
HomeMy WebLinkAboutEngineered Plan - 2016SYSTEM PROFILE (NOT TO SCALE) ACCESS COVERS TO WITHIN 6" OF FIN. GRADE 2" PEASTONE OR GEOTEXTILE D. EL. 40.4' 1 FILTER FABRIC OVER STONE 39.5' MINIMUM .75' OF COVER OVFR PRECAST PRECAST H-10 37.7'* RISERS (n?.) INV. #1 INV. #2 37.5'* 36.73' „O ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. CONCRETE COVERS TO WITHIN 3" GRADE 2% SLOPE REQUIRED OVER SYSTEM WATERTEST D'BOX FOR LEVELNL55 BLOCKS OR F-1 MIN. 2" WALL THICKNESS PRECAST RISERS 4"OSCH40 PVC MORTAR ALL INVERT IN 36.17' _.. PIPES LEVEL IST 2' COMPONENTS / EN4 DS (TYP') SIDES 37.0' 10" 1500 GAL H-10 t4" y f ,1\3 oo > o o°o o ..:. •.. 0=E TEE SEPTIC TANK TEE �0��® ®®®�- o M!lo000000000000000 6.48 0 0 0 0 00o00-oo . ��a�®DO®®®® ®®®LJ�a��� GAS BAFFLE:.' ;°o°0000000? o�o.,0000 0���(]�00��® ®��®®����00000000 'oo-o-o-o �ooa�oo�a�� �o�a�a�o�oo�00000 36.44' 36.27' >00000000 00000eoo 34.17 4' LIQ. LEVEL (ACME OR EQUAL) '000000o0 �-o-000° 0o000000000000000e000000zo6o;o;o6o0o.o00 }I ooMno„ooqo,,000000000000lo�o9o-2„0000000. 3/4"-1-1/2" DOUBLE WASHED STONE 4' MIN.LH-10 500 GAL. LEACHING CHAMBERS BY ACME PRECAST OR EQUAL ALL AROUND PRECAST STRUCTURES (2) UNITS REQUIRED 6" CRUSHED STONE OR MECHANICAL OVERALL DIMENSIONS TO OUTSIDE OF STONE: 25.00' X 12.83' COMPACTION. (15.221 [21) (1---2-7. SLOPE) FOUNDATION 44' 1 % ( SLOPE) (--1-7. SLOPE) LEACHING SEPTIC TANK 4' D' BOX 12' FACILITY 29.0' BOTTOM TH-1 FOUNDATION 10' NO GROUNDWATER FOUND (2--7P. SLOPE) *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM LEGEND- 99- EGEND 99- EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. -[991-- PROPOSED CONTOUR 198.41 PROPOSED SPOT EL. TH1 TEST HOLE 2YYY= SLOPE OF GROUND UTILITY POLE FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING TEST HOLE LOGS ENGINEER: CRAIG J. FERRARI, SE #13871 WITNESS: AMY VON HONE, RS DATE: 4/20/ 1,5' IG PERC. RATE _ < 2 MIN/INCH CLASS I SOILS ELEV. 1 p" 40.0' A LS 6" 1OYR 3/2 B LS 21 „ 1 OYR 5/6 38.3' PERC C MS 1OYR 7/6 132" 29.0' NO GROUNDWATER ENCOUNTERED DCE #16-102 7 0 m Scale: 1 "= 20' 0 10 20 30 40 50 FEET NOTES 1. DATUM IS NAVD 88 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H -LQ 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. LOCUS MAP NOT TO SCALE ASSESSORS MAP 115 PARCEL 4 VARIANCES REQUESTED: UNDER MAX. FEASIBLE COMPLIANCE 15.405: (1b): REDUCTION IN SETBACK, SAS TO FOUNDATION (20' TO 17.3') SYSTEM DESIGN: LIVINGDINING GARBAGE DISPOSER IS NOT ALLOWED BEDROOM EXISTING 3 BEDROOM DWELLING GARAGE DESIGN FLOW: 3 BEDROOMS @ 110 GPD = 330 GPD KITCHEN BATH USE A 330 GPD DESIGN FLOW 1. BEDROOM BATH -._ BEDROOM - - ---- - - -- --- �\ SEPTIC TANK: 330 GPD (2) = 660 AN USE A 1500 GAL. SEPTIC TANK FLOOR PL \ NOT TO SCALE LEACHING: SIDES: 2 (25 + 12.83) 2 (.74) = 112 GPD Pa v o BOTTOM 25 x 12.83 (.74) = 237 GPD TOTAL: 472 S.F. 349 GPD w = USE (2) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH 4' STONE ALL AROUND Permit valid for RV..PAIR OF SEP -1I( SYS'1'f:111 ONLY, dbe to State and I ueal scPf" %ariancrs. Board of health review all" 110iffoval is ,cquired for anv future additions/renanationsialter:tlions to sewage facilities and/or struc1u1 Cs/(IN~cllu)l;. Yarmouth flea1111 Department APPR(W ED /- ( a APPROVED DATE BOARD OF HEALTH TITLE 5 SITE PLAN OF #7 DEVONSHIRE LANE Name YARMOUTHPORT, MA Date PREPARED FOR JUDITH KENNEALLY 5-r\ - K. DATE ."-d- DANIEL A. OJALA, P.E., P.L.S. DATE: MAY 9, 2016 off 508-362-4541 I fax 508-362-9880 downcope.com aewn cape engineering, Inc. civil engineers land surveyors 939 Main Street ( R to 6A) YARMOU THPOR T MA 02675 0 z . , MA WIN