Loading...
HomeMy WebLinkAbout83-1144 - Site Plan1 +y LOCUS MAP AV SEPTIC SYSTEM INVERT ELEVATIONS CROSS—SECTION PROPOSED TOP $2-k2 DIST. BOX IN OF FOUNDATION lO DIST. BOX OUT 3'',�D LEACHING SYSTEM IN l�.p,oSEPTIC TANK IN \ / SEPTIC TANK OUT_ LEACHING SYSTEM BOTTOM EXIT 1'ia`T X71 DESIC3N CALCULATIONS FOR A BEDROOM HOUSE WITH t�o GARBAGE DISPOSAL SEPTIC TANK, 440 X•150 x ' &O USE A 1660 GALLON TANK LEACHING P/T%US/NG? -6'X L 'P/T W/ Z 'STONE AREA S/DEWALL I HEIGHT X 2 X TT X RADIUS X 2 x ZT X FLOW 58'5 S.F. X �'�' GPDIS.F, 71i,V�GPD BOTTOM.' 7T(RAD/US)2 77 �> ! 2= -7$,3 SF x 1 ' GPD/S.-r =7Q" 5 GPD 554,k S. F. : TOTAL (L FCTS } ' I C) q�l .2; GPD DESIGN FLOW : 4- 4� o GPD It RESERVE _ /-,5q,5 GPD Pitch I/4 Per Foot(Min., z 2% GRADE (Min.) —� o 2' of y8 -:%2 woshed stone Z—�3'Mln. 2 Min. ` 2 Min. q7LAI L LEVEL FOR 7 on o 4-0°LlquldDIST. BOX 6 S Level c ....., ........., ..;..:...•• Pitch 1/8 Per Foot IS $ Qy 11 1000 (Min.) GALLON SEPTIC TANK o it 3/4 -1 %2 4" Schedule 40 P.V.C. Washed Stone Or Equivalent NOT TO SCALE LEACHING PIT �Z TYPICAL CROSS-SECTION KEY EXISTING ELEVATIONS X EXISTING CONTOURS /10f PROPOSED CONTOURS —'-'E•— TESTPIT LOCATION CATCH BASIN UTILITY POLE F.B. Vl' 1 F{•Z LOT 9 NOTES ELEVATIONS SHOWN ARE /N FEET ABOVEI ACCESS COVERS OF THE SEPT/C SYSTEM ARE TO BE WITHIN /2 "OF PROPOSED GRADE. THERE IS TO BE ONE FOOT OF GROUNDCOVER OVER THE SEPTIC SYSTEM. CONSTRUCTION OF THE SEPTIC SYSTEM IS 70 CONFORM TO THE STATE SANITARY CODE, TITLE Y, AND THE TOWN OF BOARD OF HEALTH REGULATIONS. DESIGN LOADING OF SEP77C SYSTEM SEPTIC TANK H - 1 STRENGTH DIST. BOX = H- I a STRENGTH ISI ; / _� / LEACHING PITH- +� STRENGTH i I SOIL TEST DATA `i', 0� I 1NUTE t`JO WATER FOUND rio WATER FOUND TEST MADE.� S- TEST MADE t' A VLO 112 -E WITH 4` ''- PER INCH DROP Q NOTES ELEVATIONS SHOWN ARE /N FEET ABOVEI ACCESS COVERS OF THE SEPT/C SYSTEM ARE TO BE WITHIN /2 "OF PROPOSED GRADE. THERE IS TO BE ONE FOOT OF GROUNDCOVER OVER THE SEPTIC SYSTEM. CONSTRUCTION OF THE SEPTIC SYSTEM IS 70 CONFORM TO THE STATE SANITARY CODE, TITLE Y, AND THE TOWN OF BOARD OF HEALTH REGULATIONS. DESIGN LOADING OF SEP77C SYSTEM SEPTIC TANK H - 1 STRENGTH DIST. BOX = H- I a STRENGTH ISI ; / _� / LEACHING PITH- +� STRENGTH i I SOIL TEST DATA `i', 0� I 1NUTE t`JO WATER FOUND rio WATER FOUND TEST MADE.� S- TEST MADE WITH A VLO 112 -E WITH L-12—IL ''- PER INCH DROP GATE AGENT, ;Li -.I T -'Y -BOARD OF HEALTH PERC. RATE, LESS THAN M DRAWN TAM CHECKED J.G. S. / P. E.S. t DATE 7/Z9 191 $ SCALE j I° = 30' f JOB NO. Y 141 SHEET OF ONE SHEETS