" SEWAGE PLAN REVIEW CHECKLIST
. Location: A.M.� Lot�� Zone of Contribution: In Out� Acreage�
_ Commercial: � Residential.
Street: /� -� �
Village: �- Floor Plan: #Bedrooms: s� ��S�`"��
Owner: �-2��-`� � Installer: �
Address: Phone: '
Phone:
Builder: Engineer:
Address: Phone: �" .2-
Phone: " ,.-���- �, �' ,�././�a�r .
�D � � �
� N/A NO
1.Re uired#of copies received
2.Date of soils exam and ercolation test not older than 2 years
3.4-5 ft of naturall occurrin ervious material, above water table ���
4.Foundation 2 ft above high oint of road H.P.: Fnd: Var.: �
5.Water line 10 ft from s tic com onents Vaz.: � -
6.Senchmark indicated and shown-NGVD if near wetlands (,�
7. S tic tank minimum 10 ft from founda.tion, deck Var.:
8.Lea ching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.:
9.Lea.ching minimum 100 ft from wetlands Var.:
10.Lea.ching minimum 150 ft from drinking welU25 ft irrigation well Var.:
11.Tank/leachin minimum 10 ft from ro erty line Var.:
12. S stem meets all other setback r uirements Var.:
13.Uses adjustment for m�ximum hi groundwater Var.: L.�
14.Leaching set 4-5 ft above adj.water or bottom o Vaz.: `.�
15.System not in to or subsoil(A,B horizons)0 5'remov
16.Proposed contours aze suitable
17. S stem meets slo e r uirements-min. 1/8", '/4" referred ��-�
18. S stem meets breakout re uirements PVC liner. � WaIL•
19. S ec�ed tee sizes are ro er, gas baffle on outlet tee
20. Sewage is under 10,000 gpd for arcel
21.No garba e dis osal
' 22. S stem ade ua.tel sized for its intended use
23.Minimum 6"stone or com acted below ta.nk and dbox
, 24.Manhole covers within 6"of ade, um cha.mber cover to grade
25.Inspection ort on pla.stic chambers/leach field
26.Electrical ermit for um cha.mber/S arate meter for du lexes
27.Pum system-2" line,wee hole,check valve,tee in dbo�pum size ;�
28. Septic tank/ chamber to be factory waterproofed �
29.Vent rovided if leaching below 3 feet, under driveway/parking
30.Buoyancy calculations for tank/ um chamber
31.En ' eer to ins ect and c ' soils: wall: commercial:
32.Engineer/Registered Sanitarian and Land Surve or stam s/signa.ture
33.H-201oadin is sub'ect to vehicular traffic, groundwater
34.Title V A lication and ermit fee, insta.11er signature
35.Founda.tion footing min. 2 feet above adjusted ound water for new house .--��
36.Deed Restriction r ired max. #bedrooms: max. flow: d
37.Check area lots for groundwater/Label oundwater in Assessor's M
.
Plan reviewed by: �o3io3