Loading...
HomeMy WebLinkAboutEngineered Plans - 2015OF Mgss9��G o PETER T. McENTEE CIVIL "' No. 35109 WETLAND DELINEATION EXISTING CESSPOOLS (approx.) CONTRACTOR SHALL LOCATE, PUMP & FILL WITH SAND & ABANDONED 9134 X e GS c� PROPOSED SEPTIC TANK 96,64 i INSTALL NEW SLEEVED WATER SERVICE -\ 100.04 N\ JACK VACCARO Environmental Consultant P.O. Box 955 Sandwich, MA 02563 (508) 888-5855 _ FLOOD ZONE DESIGNATION MAP NO. 25001CO579J EFFECTIVE DATE: JULY 16, 2014 ZONE X & AE (EL9) E-CEIVE --96 - -EXISTING CONTOUR 1 "=20' x 90.12 EXISTING SPOT GRADE ,� 1 g 7016 %-N/ [HEALTH x 0 PROPOSED SPOT GRADE ` I + 80,51 1 ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL EXISTING WATER SERVICE DEPT. X11/- PROPOSED WATER SERVICE X 83.33 OF LINER, EL.93.0 (SLEEVED) N BOTTOM OF LINER, EL.88.0 11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS -a H.4y- OVERHEAD WIRES I V-1050 WETLAND FLAG x 82,67 6,98 12. AREAS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE END OF DRIVEWAY) __4!L WETLAND SYMBOL APPROXIMATE FLOOD � ZONE BOUNDARY \ MBL TEST PIT r V1 / 2) A 3' variance, SAS to property line (side), for an 7' setback. i 14. THE CONTRACTOR IS RESPONSIBLE TO TAKE ALL MEASURES TO MAINTAIN BENCHMARK THE STRUCTURAL STABILITY OF ADJACENT STRUCTURES. 3) A 5' variance, septic tank to cellar wall, for a 5' setback. WORK LIMlT(TYP.) 84,54\ x �l, 7332±SF LEGEND 0 Hu nCm°k 0 N o /®�° LOCUS � y �I TasOmon°Zr `\ ° \� Swamp i Cove o� I LOCUS MAP NOT TO SCALE -OA - -4 08` - 7) 24' variance requested, for 76' to B.V.W. x 87 62 �Q� ` - x 84,86 3' TOESEWAGE INSPECT INSPECTION AND APPROVAL SPOSAL I BY SHALL HE NBOARD OFCHEALTH-AND OT BE THE �X 88,11 DESIGN ENGINEER. \� x 87`� �8� 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING x 8 9.2 5"' ACCESS ALLY FOR FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN SKID STEER TO FILL ENGINEER BEFORE CONSTRUCTION CONTINUES. 88,14 TP CESSPOOLS 5. ALL ELEVATIONS BASED ON NAVD88. q 8.1 �� 87,8 ' -88 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF 9.33 .��i r HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. M �L 344!4 / W/CELLAR BELC ,EXISTING' h HOUSE(#394'A / % T. 0. F. = 95.44±' x.195,95 In A R ��� ► 94.1 99,88 STON ��'; _ ::...�..•; 99 57 99,14 97`S ��<< 9 OF ASN OF MASS GA'4l/�cC _ 97.71E �cyGs /GY 99,01 DANIEL A 98,76 9 , OJALA + ° No. 40980 98.47 98,53 o�Fss�oaO PLAN REVISION qy0 SU NES _ _ 1) ADD WORK LIMIT & SILT FENCE 2) ADD ACCESS ALLY FOR SKID STEER 3) ADD LOCAL VARIANCE REQUEST, SEC. 3.7 V 1 '\GENERAL 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. 1 "=20' 81,,00 3 8. THERE ARE NO WELLS WITHIN 100' OF THE PROPOSED SEPTIC SYSTEM. NOTES: LOT 3 \ ` I + 80,51 1 ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE a INSTAL4_ 40 MIL POLY F� e / c'F` `-----VEGETATED BOARD OF HEALTH AND THE DESIGN ENGINEER. X 83.33 OF LINER, EL.93.0 �� WETLAND 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS N BOTTOM OF LINER, EL.88.0 11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS 0)) --94- �'� OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE X 88.13 , CRUSHED STONE DRIVEWAY e 57� LOCAL RULES AND REGULATIONS; EXCEPT AS REQUESTED BELOW: 12. AREAS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE END OF DRIVEWAY) LOT 4 �` �- -310 CMR 15.405(1)(a)(b)&(g): �� 4 1) A 4' variance, septic tank to property line (front), for a 6' setback. APPROXIMATE FLOOD � ZONE BOUNDARY \ MBL � e `x 136-196` ' r V1 / 2) A 3' variance, SAS to property line (side), for an 7' setback. i 14. THE CONTRACTOR IS RESPONSIBLE TO TAKE ALL MEASURES TO MAINTAIN 75' BUFFER THE STRUCTURAL STABILITY OF ADJACENT STRUCTURES. 3) A 5' variance, septic tank to cellar wall, for a 5' setback. WORK LIMlT(TYP.) 84,54\ 83.08 x 7332±SF V102 4 A 10' variance, SAS to cellar wall, for an 10' setback. V101 ) SILTATION FENCE x -- -8-4 -._ + 83.46 � 83,50 5) A 3' variance to max. cover requirement, for 5' of cover over SAS. ®83,32 x 83,57 �....,, 6) To install a sleeved water service within 10' of the septic tank. � -*LOCAL REGULATION SECTION 37 -OA - -4 08` - 7) 24' variance requested, for 76' to B.V.W. x 87 62 �Q� ` - x 84,86 3' TOESEWAGE INSPECT INSPECTION AND APPROVAL SPOSAL I BY SHALL HE NBOARD OFCHEALTH-AND OT BE THE �X 88,11 DESIGN ENGINEER. \� x 87`� �8� 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING x 8 9.2 5"' ACCESS ALLY FOR FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN SKID STEER TO FILL ENGINEER BEFORE CONSTRUCTION CONTINUES. 88,14 TP CESSPOOLS 5. ALL ELEVATIONS BASED ON NAVD88. q 8.1 �� 87,8 ' -88 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF 9.33 .��i r HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. M �L 344!4 / W/CELLAR BELC ,EXISTING' h HOUSE(#394'A / % T. 0. F. = 95.44±' x.195,95 In A R ��� ► 94.1 99,88 STON ��'; _ ::...�..•; 99 57 99,14 97`S ��<< 9 OF ASN OF MASS GA'4l/�cC _ 97.71E �cyGs /GY 99,01 DANIEL A 98,76 9 , OJALA + ° No. 40980 98.47 98,53 o�Fss�oaO PLAN REVISION qy0 SU NES _ _ 1) ADD WORK LIMIT & SILT FENCE 2) ADD ACCESS ALLY FOR SKID STEER 3) ADD LOCAL VARIANCE REQUEST, SEC. 3.7 OWNER OF RECORD BENCHMARK 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. 1 "=20' TOP OF CONC. WALL 8. THERE ARE NO WELLS WITHIN 100' OF THE PROPOSED SEPTIC SYSTEM. WAKEBY DEVELOPMENT CORP. EL.=94.44 9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS x 90.58 AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE a INSTAL4_ 40 MIL POLY DIRECTED BY THE APPROVING AUTHORITIES. `LINER -��TOP 10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY OF LINER, EL.93.0 THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION. N BOTTOM OF LINER, EL.88.0 11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS 0)) --94- IN THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S., OR INSTALL NEW SLOPED AS OTHERWISE DIRECTED AND REPLACE WITH CLEAN SAND AS SPECIFIED CRUSHED STONE DRIVEWAY IN 310 CMR 15.255(3). (INSTALL WHEEL STOPS AT 12. AREAS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE END OF DRIVEWAY) INSPECTED BY DESIGN ENGINEER PRIOR TO BACKFILL. 13. THE ENGINEER IS NOT RESPONSIBLE FOR ANY UNDOCUMENTED EXISTING 96,12 SEPTIC SYSTEM COMPONENTS NOT SHOWN ON THE PLAN. 14. THE CONTRACTOR IS RESPONSIBLE TO TAKE ALL MEASURES TO MAINTAIN 75' BUFFER THE STRUCTURAL STABILITY OF ADJACENT STRUCTURES. g -'- - - TO W7L4NDS 15. PROPERTY LINES SHOWN HAVE BEEN DETERMINED BY EXAMINING THE VENT PLAN OF RECORD AND SURROUNDING PLANS OF RECORD AND ARE 95,71 APPROXIMATE. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY, AND IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY. WORK LIMPROPOSED SILTATIONION FENCENCE F SEPTIC SYSTEM UPGRADE PLAN -PROPOSED S.A.S. 394A NORTH DENNIS RD., YARMOUTHPORT, MA Prepared for: Wakeby Development Corp., 2 Jillson Way, E. Sandwich, MA 02537 Engineering by: Survey Review by: SCALE DRAWN JOB. NO. OWNER OF RECORD Engineering Works, Inc. Down Cape Engineering 1 "=20' P.T.M. 218-15 WAKEBY DEVELOPMENT CORP. 12 West Crossfield Road 939 Main St., Suite C 2 JILLSON WAY Forestdole, MA 02644 Yarmouth Port, MA 02675 DATE CHECKED SHEET N0. EAST SANDWICH, MA 02537 (508) 477-5313 (508) 362-4541 11/25/15 P.T.M. 1 Of 2 SEPTIC TANK INSTALL RISERS & COVERS OVER INLET & OUTLET AND SET TO 6" OF FINISH GRADE T.O.F=95.44± F.G. EL.=95.0± L = 11' ® S=1% (MIN.) 4"SCH40 PVC INV.=93.00 INSTALL NEW SEWER C AT HOUSE, INV.=93.44 F.G. EL.=95.1± 3'(max.) 48" LIQUID - LEVEL ADD GAS BAFFLE PROPOSED D -BOX INSTALL RISER & COVER SET TO 6" OF GRADE L = 35' @S=1% (MIN.) 4"SCH40 PVC NOTES: 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE INVERTS, PRIOR TO INSTALLATION. 2) SEPTIC TANK & D -BOX SHALL BE SET LEVEL AND TRUE TO GRADE ON A MECHANICALLY COMPACTED SIX INCH CRUSHED STONE BASE, AS SPECIFIED IN 310 CMR 15.221(2). 3) INSTALL INLET & OUTLET TEES AS REQUIRED. 4) GAS BAFFLE TO BE INSTALLED ON OUTLET TEE AS MANUFACTURED BY TUF-TITE, ZABEL OR EQUAL. DESIGN CRITERIA F.G. EL.=95.1 ± L = 16' ® S=1% (MIN.) 4"SCH40 PVC INV.=92.33-/ PROPOSED `INV.=92.16 NV.=92.75 D-60 3 OUTLETS INV.=92.00 TOP CONC. ELEV.=93.1 t - BREAKOUT ELEV.=92.50 - INV. ELEV.=92.00 - BOTTOM ELEV.=90.00 - 4' OF NATURALLY OCCURRING PERVIOUS MATERIAL 5' (MIN.) ABOVE G.W. ADJUSTED G.W., EL.=81.6 SEPTIC SYSTEM PROFILE NUMBER OF BEDROOMS: 2 BEDROOMS SOIL TEXTURAL CLASS: CLASS I (EFFLUENT LOADING RATE=0.74 GPD/SF) DESIGN PERCOLATION RATE: <2 MIN/IN DAILY FLOW: 220 GPD DESIGN FLOW: 220 GPD GARBAGE GRINDER: NO -not allowed with design LEACHING AREA REQUIRED: (220 GPD) = 297.3 SF .74 GPD/SF PROPOSED SEPTIC TANK: 1500 GALLON CAPACITY PROPOSED D -BOX: 1 INLET, 3 OUTLET (MINIMUM), H-10 RATED USE 1-500 GALLON LEACHING CHAMBER SURROUNDED WITH 3/4" to 1-1/2" DOUBLE WASHED STONEWALL SIDES SIDEWALL AREA: 2(12.8' + 16.5') x 2 = 117.2 SF BOTTOM AREA: 12.8' x 16.5' = 211.2 SF TOTAL AREA: .............................................................. 328.4 SF DESIGN FLOW PROVIDED: 0.74 GPD/SF(328.4 SF) = 243.0 GPD NOTE: TO PREVENT BREAKOUT, FINAL GRADE SHALL NOT BE AT, OR BELOW, EL.=92.5 FOR A DISTANCE OF 15' FROM THE EDGE OF THE PROPOSED S.A.S. PROPOSED S.A.S. ±ROOF DECK INSTALL H-20 RISER, FRAME & COVER OVER CHAMBER W/CELLAR BELOW SET TO 3" OF F.G. TO SERVE AS INSPECTION PORT F.G. EL.=�5.5± to 98.0±/"/ I veNr ,. ,EXISTING ' �" HOUSE(#394A)� T.O. F. =95.44±' -2- LAYER OF 1/8- TO 1/2" DOUBLE WASHED STONE (OR APPROVED FILTER FABRIC aaaaaaa --3/4" TO 1-1/2" DOUBLE 5.2' 14'1 WASHED STONE I / EFFECTIVE WIDTH =.12.8' I 4' I 8.5' ' I 4' I EFFECTIVE LENGTH = 16.5' 1 SOIL LOG DATE: SEPTEMBER 10, 2015 SOIL EVALUATOR: PETER McENTEE (SE#1542) WITNESS: AMY VON HONE !R.S.- HEALTH AGENT Elev. TP Depth 87.9 A 0" LOAMY SAND 1OYR 4/2 87.4 B LOAMY SAND 10YR 5/4 85.4 C MED. SAND 2.5Y 6/6 81.6 ADJ. G.W. - SOILS AT PROPOSED S.A.S. LOCATION SHALL BE VERIFIED PRIOR TO INSTALLATION. 0 PERC 14"/32" 30" 77.9 G.W. - 60" 77.4 1 126" PERC RATE <2 MIN/IN. ("B & C" HORIZONS) STANDING G.W. @ 120", (EL.=77.9) INDEX WELL, AIW-247, ZONE B WATER LEVEL=24.4 (AUG 2015), ADJUSTMENT=3.7' LIN 0) p �. X36 /8.0'`�� S.A.S. f 00 SEPTIC LAYOUT � � til t+ t�f t�1 1�1 til tit til tit t�f 1.1 (�ll�It�f1.1t�1t�lt�tt�lt�tt�t1.1 102" 500 GALLON CAPACITY, H-20 LOADING CHAMBERS N.T.S. 37" 58" PROPOSED SEPTIC SYSTEM UPGRADE PLAN 394A NORTH DENNIS RD., YARMOUTHPORT, MA Prepared for: Wakeby Development Corp., 2 Jillson Way, E. Sandwich, MA 02537 Engineering by: Survey Review by: SCALE DRAWN JOB. NO. Engineering Works, Inc. Down Cape Encgmeermg N.T.S. P.T.M. 218-15 12 West Crossfield Road 939 Main St., Suite C DATE CHECKED SHEEP N0. Forestdole, MA 02644 Yarmouth Port, MA 02675 (508) 477-5313 (508) 362-4541 11/25/15 P.T.M. 2 Of 2 4" KNOCKOUT 20" DIA. COVER 4" KNOCKOUT0 / 4" KNOCKOUT 4" KNOCKOUT 500 GALLON CAPACITY, H-20 LOADING CHAMBERS N.T.S. 37" 58" PROPOSED SEPTIC SYSTEM UPGRADE PLAN 394A NORTH DENNIS RD., YARMOUTHPORT, MA Prepared for: Wakeby Development Corp., 2 Jillson Way, E. Sandwich, MA 02537 Engineering by: Survey Review by: SCALE DRAWN JOB. NO. Engineering Works, Inc. Down Cape Encgmeermg N.T.S. P.T.M. 218-15 12 West Crossfield Road 939 Main St., Suite C DATE CHECKED SHEEP N0. Forestdole, MA 02644 Yarmouth Port, MA 02675 (508) 477-5313 (508) 362-4541 11/25/15 P.T.M. 2 Of 2