HomeMy WebLinkAboutEngineered Plan - 201612.5' PRECAST H-10 RISERS (TYP.) 2'010.4' 9.36' SYSTEM PROFILE (NOT TO SCALE) PROVIDE MIN. 20" DIAM. WATERTIGHT ACCESS COVERS TO WITHIN 6" OF FIN. GRADE 12.0' t,IlAnUMA 7r AC P`AVCD A%MD 001-IACT 4"OSCH40 PVC 6" MIN. SUMP PIPES LEVEL 1 ST 2' 12" MIN. INT. DIM. 10" 1500 GAL H-10 14" TEE SEPTIC TANK TEE 9.1 1 ' "00,-* ATERIEST D'BOX GAS BAFFLE `OR LEVELNESS8.75 4' UQ. LEVEL (ACME OR EQUAL)8.95'8.78' 00('000 0 0 0 0 0 O00000000000 O O O O O O O O O O O0 o 0 O�'t 0 0 0 O°O°O°O°O°O°O°O°O°O°O°O°O°O°O°O°O°O°O°O°O° 3_8 q SLOPE) 27' - FOUNDATION 14' - (4.5 % SLOPE) LEGEND- 99- EGEND 6" CRUSHED STONE OR MECHANICAL L-- COMPACTION. (15.221 [21) (--!-% SLOPE) (-!-% SLOPE) SEPTIC TANK 16' D' BOX 5' - 99- EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. -[99]-- PROPOSED CONTOUR [98.4] PROPOSED SPOT EL. TH1 SOILS 2. TEST HOLE 2YY2= SLOPE OF GROUND CQ) UTILITY POLE 9Y FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR MI DRAWING *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM TEST HOLE LOGS ENGINEER: CRAIG J. FERRARI, SE #13871 WITNFgC• PHIL RENAUD DATE: 5/18/2016 1. PERC. RATE _ < 2 MIN/INCH Locus ornin m CLASS I SOILS 2. MUNICIPAL WATER IS EXISTING 1 ELEV. 0" co 00 Q, 12' 2% SLOPE A/E MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. FILTER FABRIC LS 4. DESIGN LOADING FOR ALL PROPOSED PRECAST 1OYR 4/2 FINISHED GRADE- 4" LOAM & SEED OR PAVE AS REQ. 709 Nantucket 330 GPD / (.74) = 446 SF REQUIRED Sound B a 9' X 50' = 450 SF OK LS 12„ 1OYR 4/6 11' C PERC MS 1OYR 6/6 DECK I I DECK BATH PORCH BEDROOM GARAGE ROOM KITCHEN LIVING ROOM FLOOR PLANS NOT TO SCALE 1 NOTES �� % 5. PIPE JOINTS TO BE MADE WATERTIGHT. CLEAN FILL 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE 4" PERFORATED PVC 3' O.C. S=O.00S O WITH 310 CMR 15.000 (TITLE 5.) 3/4"-1-1/2" DOUBLE WASHED 9STONE LEACHING FIELD 0 DEPTH MIN BELOW INV. 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND ' 6" /, 8 50' l NOT TO BE USED FOR LOT LINE STAKING OR ANY LEVEL BOTTOM 0 OTHER PURPOSE. im LEACHING FACILITY III Kkft�17 F�12 GARAGE i G -W ADJ. DATA: WELL: MIW 29 ZONE: A ADJ: 1.1' 132" I I 1, GROUNDWATER ENCOUNTERED 120" - EL. 2.0' DCE # 16-126 Scale:1 "= 20' 0 10 20 30 40 50 FEET 8.1' 5.0' 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR 1. DATUM IS NAVD 88 MARK CORNERS OF Locus ornin m LEACHING FIELD W/ PROVIDE INSPECTION PORTS TO 2. MUNICIPAL WATER IS EXISTING REBAR SET 4" BELOW WITHIN 3" OF FINISH GRADE .44. 0 co 00 Q, GRADE /El2.0 2% SLOPE 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. FILTER FABRIC � 4. DESIGN LOADING FOR ALL PROPOSED PRECAST TOP 9.1' FINISHED GRADE- 4" LOAM & SEED OR PAVE AS REQ. UNITS TO BE AASHO H-ZQ �� % 5. PIPE JOINTS TO BE MADE WATERTIGHT. CLEAN FILL 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE 4" PERFORATED PVC 3' O.C. S=O.00S O WITH 310 CMR 15.000 (TITLE 5.) 3/4"-1-1/2" DOUBLE WASHED 9STONE LEACHING FIELD 0 DEPTH MIN BELOW INV. 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND ' 6" /, 8 50' l NOT TO BE USED FOR LOT LINE STAKING OR ANY LEVEL BOTTOM 0 OTHER PURPOSE. im LEACHING FACILITY III Kkft�17 F�12 GARAGE i G -W ADJ. DATA: WELL: MIW 29 ZONE: A ADJ: 1.1' 132" I I 1, GROUNDWATER ENCOUNTERED 120" - EL. 2.0' DCE # 16-126 Scale:1 "= 20' 0 10 20 30 40 50 FEET 8.1' 5.0' 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR 3.1' ADJUSTED GROUNDWATER CALLING DIGSAFE (1-888-344-7233) AND G -W ADJ. DATA: VERIFYING THE LOCATION OF ALL UNDERGROUND & LOCUS MAP WELL: MIW 29 OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. NOT TO SCALE ZONE: A ADJ: 1.1' 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE ASSESSORS MAP 33 PARCEL 131 PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED LOCUS IS WITHIN FEMA FLOOD ZONE X (0.2 AND REMOVED OR PUMPED AND FILLED WITH CLEAN PCT ANNUAL CHANCE FLOOD HAZARD) AS SAND. SHOWN ON COMMUNITY PANEL #25001CO589J DATED 7/16/2014 VARIANCES REQUESTED: UNDER MAX. FEASIBLE COMPLIANCE 15.405: (1b): REDUCTION IN SETBACK, SAS TO FOUNDATION (20' TO 16') TH 1 (TYP) o.z '�JBENCHMARK: COR. BULKHEAD =12.2 NAVD88 EXISTING DWELLING TOF = 1 2 .5' f � 12 3 LOT 68 8,850± SF x 0• x x - GA Y ROAO SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED 4°0� G�0 S�'fie Locus ornin m DESIGN FLOW: 3 BEDROOMS CSA 110 GPD = 330 GPD ow t. ,S to { Cb °' o cn c �q; N .44. 0 co 00 Q, � o 0 m' p d a � m Shore or. or el Uth Nantucket 330 GPD / (.74) = 446 SF REQUIRED Sound a 3.1' ADJUSTED GROUNDWATER CALLING DIGSAFE (1-888-344-7233) AND G -W ADJ. DATA: VERIFYING THE LOCATION OF ALL UNDERGROUND & LOCUS MAP WELL: MIW 29 OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. NOT TO SCALE ZONE: A ADJ: 1.1' 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE ASSESSORS MAP 33 PARCEL 131 PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED LOCUS IS WITHIN FEMA FLOOD ZONE X (0.2 AND REMOVED OR PUMPED AND FILLED WITH CLEAN PCT ANNUAL CHANCE FLOOD HAZARD) AS SAND. SHOWN ON COMMUNITY PANEL #25001CO589J DATED 7/16/2014 VARIANCES REQUESTED: UNDER MAX. FEASIBLE COMPLIANCE 15.405: (1b): REDUCTION IN SETBACK, SAS TO FOUNDATION (20' TO 16') TH 1 (TYP) o.z '�JBENCHMARK: COR. BULKHEAD =12.2 NAVD88 EXISTING DWELLING TOF = 1 2 .5' f � 12 3 LOT 68 8,850± SF x 0• x x - GA Y ROAO SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED EXISTING 3 BEDROOM DWELLING DESIGN FLOW: 3 BEDROOMS CSA 110 GPD = 330 GPD USE A 330 GPD DESIGN FLOW SEPTIC TANK: 330 GPD (2) = 660 USE A 1500 GAL. SEPTIC TANK LEACHING: 330 GPD / (.74) = 446 SF REQUIRED 0 a 9' X 50' = 450 SF OK p 450 SF X .74 = 333 GPD OK USE A 9' X 50' PIPE AND STONE LEACHING FIELD Z f APPROVED Permit valid for Rt:PAIR 01f SF,1' 1'1(- SYS I -Em ONLY, d'ue to State and I +gyral septic variances. Board of Health revietit and .+ppro%,d is required for titure to sewage faedities and/or strueto, celd�n IhnK. Yarmouth 11vailh Department APPRO V EW 5e7'0_10 -r C Date DATE U/11VIGL h. UUMLM, F.L.., F.L.a. , MA DATE BOARD OF HEALTH TITLE 5 SITE PLAN OF #6 GAY ROAD SOUTH YARMOUTH, MA PREPARED FOR DYAN REDICK DATE: MAY 24, 2016 off 508-362-4541 I fax 508-362-9880 downcape.com down cope engiaeeriag, inc. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675