Loading...
HomeMy WebLinkAboutEngineered Plan - Rev. 20160" 3" 3611 PERC @ 48" 3 MIN/IN 50" SOIL LOG GENERAL NOTES: T. P. # 1 EL 12.15 A'S. L. 10 YR 5/4 'B' SAND 10 YR 6/6 'C1' SAND 10 YR 6/5 'C2' MED. SAND 2.5 YR 6/4 108„ NO MOTTLES WATER AT 4.05 * PERCOLATION TEST LOCATION: T P. # 1 ; BOTTOM OF TEST HOLE= 48 PERCOLATION TEST AND DETERMINATION OF SUB -SOIL CONDITIONS WERE DONE ON 4-12, 2016, AS WITNESSED BY B MURPHY, B. 0. H. AGENT SOIL EVALUATOR: FRANK IEBBA, PLS, PE CIV/SAN TOP OF FNDN. EL. =14.9' (BENCHMARK) PROVIDE RISER FOR COVER 4" DIA. CAST IRON OR AT GRADE OR MAX. 6" BELOW FINISH GRAD SCH. 40 PVC PIPE \NV. =11.9' _SLOPE = 2% �- 1. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH MASS. TITLE 5 AND LOCAL BOARD OF HEALTH REGULATIONS, EXCEPT AS PERMITTED BY VARIANCES AS NOTED HEREON. 2. ALL COMPONENTS SHALL BE INSTALLED ON A LEVEL. STABLE BASE THAT WILL NOT SETTLE. PIPE SHALL BE LAID ON A FIRM BASE, FREE OF STONES. PRE -CAST CONCRETE TANKS SHALL BE MINIMUM 'H-1 0' AASHTO RATING OR 'H-20' RATING WHERE NOTED. DISTRIBUTION BOX SHALL HAVE COVER AT GRADE. 3. BUILDING SEWER SHALL BE CAST IRON OR SCH.40 P.V.C. PIPE; GRAVITY EFFLUENT PIPES SHALL BE SCH.40 P.V.C. PIPE. PUMPED EFFLUENT PIPE SHALL BE SCH.40 P.V.C. OR POLYETHYLENE PIPE. 4. WASHED STONE AND PEASTONE SHALL BE DOUBLE -WASHED STONE. FREE OF IRON, FINES AND DUST IN PLACE, WITH LESS THAN 2/10 % FINER THAN # 200 SIEVE. STONE WITH EXCESS FINES SHALL BE REPLACED AT NO EXPENSE TO THE OWNER. 5. THE ENGINEER CERTIFIES TO THE SOIL CONDITIONS AND PERCOLATION RATE ONLY IN THE AREA TESTED. THE INSTALLER SHALL NOTIFY THE ENGINEER*IF SOIL CONDITIONS ARE FOUND DIFFERENT THAN SHOWN ON'SOIL LOG'. 6. PRIOR TO FINAL COVER OF SYSTEM, THE INSTALLER SHALL NOTIFY THE ENGINEER TO MAKE AN'AS- BUILT' INSPECTION. FINAL COVER SHALL NOT BE PLACED UNTIL SYSTEM IS APPROVED BY THE ENGINEER AND THE BOARD OF HEALTH. SITE NOTES: 1. THIS PARCEL IS SHOWN AS LOT 105 OF ASSESSORS MAP 24. 2. THIS PARCEL SHOWN HEREON DOES NOT LIE WITHIN A SPECIAL FLOOD HAZARD AREA AS DELINEATED ON F.E.M.A. COMMUNITY PANEL 3. REMOVE UNSUITABLE SOILS BENEATH THE LEACHING FIELD AND TO A 5 -FOOT DISTANCE ON SIDES WHERE SHOWN, AND REFLACE WITH CLEAN, COARSE SAND UP TO LEVEL OF PEASTONE COVER. THE BOTTOM AND SIDES OF THE OVERDIG EXCAVATION SHALL BE SCARIFIED AND EQUIPMENT SHALL NOT BE OPERATED ON THE SCARIFIED SURFACES PRIOR TO BACKFILLING. 4. THER ARE NO WETLANDS WITHIN 100 FT OF THE PROPOSED WORK. 5. NOTIFY DIG -SAFE PRIOR TO ANY EXCAVATION. 6. THIS DESIGN CONFORMS TO MASS. TITLE 5 7. CESSPOOLS TO BE PUMPED, REMOVED AND INSPECTED BY B.O.H. 8. LINE FROM DISHWASHER SHALL BE RECONNECTED TO MAIN SEWER LINE. 9. B -LAYER 5 FT AROUND PERIMETER OF SAS WILL BE EXCAVATED AND REPLACED WITH FINE GRAIN GRANULAR SOIL FREE OF ANY ORGANICS AND IN ACCORDANCE WITH MASS TITLE T SPECS. INV.= 122 EXISTING TO REMAIN FOOTING 8.4 611 311 SLOPE =1 LIQUID LEVEL 911 3 17 I I 10 14 �INV.=11.7/ INV. =11.5 TEES MUST BE VISIBLE WITH COVERS REMOVED (TYPICAL) 4811 / 34 GAS & SOLIDS DEFLECTOR @ TANK OUTLET 101-611 L. x 51.811 W. NEW (1) -1500 GAL. SEPTIC TANK SYSTEM DESIGN DATA: PERCOLATION RATE = 3 MIN./INCH BOTTOM& �IDE L. T.A.R. = 0.74GPD/S.F. BOTTOM ARBA = 22' W. x 21'L. = 462 S.F. SIDE AREA ; = N/A = 0 S.F. TOTAL tEACHING AREA = 462 S.F. DESIGN FL gW RATE: SINGLE -UNIT DWELLING 3 BR'S DESIGN FLgW RATE : 3 B.R.'s @ 110 GPD= 330 GPD. (MIN.) TOTAL MINI UM DESIGN FLOW = 330 GPD SYSTEM CAj9ACITY = (462 S.F. x 0.74 GPD/S.F.) = 342 GPD 2" PEASTONE COVER OR, GEO-TEXTILE CLOTH e BED BOTTOM AT 10.7 FIELD INSPECTION PORT.- 4"D. PERF. PIPE WITH SCREW CAP IN ELECTRIC OR IAIATrnl/AI I/r MW � nnAnr Y I IV rYJ VI `t 1 Lill. 1 11 L ALU I L U.U.- CROSS .U.-CROSS SECTION THRU FIELD NOT TO SCALE BEDROOM I BEDROOM LIVING ROOM BATH i BASEMENT HAS NEVER EXPERIENCED GROUNDWATER AND WAS INSPECTED BY TOWN BOH AT TIME OF SOIL TEST i PATIO s INV.=11.9' INV. INV. 11.5' a 130.24' W INV.= 122' EXISTING TO REMAIN 22. rEsrPrr c=R> EXISTING CESSPOOL AND TANK WILL BEABANDONED, REMOVED f OM ZSITE GROUND R. 1215 AND INSPECTED AND APPROVED BY TOWN B.O.H. (GROUND WATER @ 4.05) PAVED DRIVE s 130.47' 3/4" -1-1/211 WASHED STONE -4-9" COVER INV 11.2 - 5 -FT. -J 0VERDIG I SITE PLAN SCALE: 1" = 20 FT. PLAN OF REPLACEMENT OF SUBSURFACE SEWAGE DISPOSAL ELEV.= 12'+1 - MIN. SLOPE = 2% -� D 30X COVER TO C RADEW 71/// W717111 7'NM7 INV. =11.25 911 MIN. 2" PEASTONE COVER OR 211 GEO-TEXTILE CLOTH 6 p CC:,° Ce °�o.:•:r.:::.::6.:1•1::.•.. $; 3411_1_1/211 ���°os °°sa oQ WASHED STONE DIS . BOX 4" PERF. PIPE, S=0.5% BOTTOM 10.7 (SEE GENERAL NOTE 4) (6 -HOLE W/ INV. =11.2 BAFFLE) 4 ROWS SCH. 40 PERF. PIPE @ 72" O.C. (CAP ENDS) 22' WIDE x 21' LONG LEACHING FIELD 5'OVERDIG - - _- SITENOTE'3' � TOTAL LEACHING AREA = 342 S.F. GROUNDWATER ELEVATION AT 4.05 BED BOTTOM AT 10.7 SECTION THRU SYSTEM _ _ 1.5 FT GROUNDWATER ADJUST NOTE SHWT ESTIMATED AT 8.1 FT NO MOTTLING TO 8.1 FT NOT TO SCALE HIGH CHROMA AND VALUE - SEE TEST PIT PREPARED FOR VINCENT ARCURI 11 PAM ET. ROA WEST YARMOUTH, SCALE: AS NOTED DATE: MAY 18, 2016 JUNE 22; 2016 JULY 6, 2016 i for REPAIR OF SEPTIC SYSTEM to State and Local septic variances. ftard of Health review and approval is required for any future additions/renovations/alterations to sewage facilities and/or structures/dwelling. Yarmouth Health Department APPROVED ESSEX ENG. &SURVEY P.O. BOX 620622 NEWTON LOWER FALLS MA. 02462-0622 617-797-7342 FRANK.IEBBA@GMAIL.COM 3. 3. m TOP FOUND 14.9 0 a TOP FOOTING 6.4 ey EXISTING HOUSE # 11 (TWO BEDROOMS) ]BMSTEP(1111NG88 N - 0 �EcorwECT LuE rraan vas► wAW R CIN f O 22. rEsrPrr c=R> EXISTING CESSPOOL AND TANK WILL BEABANDONED, REMOVED f OM ZSITE GROUND R. 1215 AND INSPECTED AND APPROVED BY TOWN B.O.H. (GROUND WATER @ 4.05) PAVED DRIVE s 130.47' 3/4" -1-1/211 WASHED STONE -4-9" COVER INV 11.2 - 5 -FT. -J 0VERDIG I SITE PLAN SCALE: 1" = 20 FT. PLAN OF REPLACEMENT OF SUBSURFACE SEWAGE DISPOSAL ELEV.= 12'+1 - MIN. SLOPE = 2% -� D 30X COVER TO C RADEW 71/// W717111 7'NM7 INV. =11.25 911 MIN. 2" PEASTONE COVER OR 211 GEO-TEXTILE CLOTH 6 p CC:,° Ce °�o.:•:r.:::.::6.:1•1::.•.. $; 3411_1_1/211 ���°os °°sa oQ WASHED STONE DIS . BOX 4" PERF. PIPE, S=0.5% BOTTOM 10.7 (SEE GENERAL NOTE 4) (6 -HOLE W/ INV. =11.2 BAFFLE) 4 ROWS SCH. 40 PERF. PIPE @ 72" O.C. (CAP ENDS) 22' WIDE x 21' LONG LEACHING FIELD 5'OVERDIG - - _- SITENOTE'3' � TOTAL LEACHING AREA = 342 S.F. GROUNDWATER ELEVATION AT 4.05 BED BOTTOM AT 10.7 SECTION THRU SYSTEM _ _ 1.5 FT GROUNDWATER ADJUST NOTE SHWT ESTIMATED AT 8.1 FT NO MOTTLING TO 8.1 FT NOT TO SCALE HIGH CHROMA AND VALUE - SEE TEST PIT PREPARED FOR VINCENT ARCURI 11 PAM ET. ROA WEST YARMOUTH, SCALE: AS NOTED DATE: MAY 18, 2016 JUNE 22; 2016 JULY 6, 2016 i for REPAIR OF SEPTIC SYSTEM to State and Local septic variances. ftard of Health review and approval is required for any future additions/renovations/alterations to sewage facilities and/or structures/dwelling. Yarmouth Health Department APPROVED ESSEX ENG. &SURVEY P.O. BOX 620622 NEWTON LOWER FALLS MA. 02462-0622 617-797-7342 FRANK.IEBBA@GMAIL.COM