Loading...
HomeMy WebLinkAbout83-1266 - Site PlanFIRST FLOOR ELEVATION_ TOP of FOUNDATION ELEVATION INVERT at FOUNDATION ELEVATION _ BASEMENT FLOOR ELEVATION FIN. GRADE AT HOUSE FIN. GRADE OVER SEPTIC TANK LEVELING RING TO WITHIN 12" OF FINISH GRADE I 3" SEPTIC SYSTEM PROFILE FIN. GRADE OVER FIN. GRADE OVER DIST. BOX LEACHING TRENCH 2" of 1/8--1/2., - I WASFIFD PEAST014E 4" Perforated PVC Pipe 2.. S >• �s.�•. 3/4" - 1-1/2" WASHED CRUSHED STONE DIST. 80X ! r---- -----�----► 15 EFFECTIVE LENGTH H-10 LOADING TO BE SET ON A - LEVEL d STABLE I 1a" EFFECTIVE BASE TOTAL NUMBER I DEPTH I ACME DB -3 OR OF APPROVED EQUAL) 5-0 ( Profile no to scale EFFECTIVE WIDTH 1 Ex I15T LEACHING TRENCH L1/F `FOVJO o1= `,(4J7-)M00TTH OVEp�Cct�OvJ>� t�,C�!r z ESE or- � C7ITG1-t � 4o' l=- �� S o'- 05'- 23 �- 3° E>u -sT- r2 ITc p (F io 5 tel'- 23 3g' E :9P� CP p 4--l' 40" F= LOT 10 2rD, 3e!>0j .5. IF \yJ } srAKE� I�vY s3c.0-E o�kE .— F AT LIMIT oP LD �\ 'PLAN REFERENCE: SARNST. CNTY. REG. PLAN SK � -Q N O Ce J p t q.7 33 < 11.15 ESGIST Ie..lCx _N t/ 3 v��nRoc�15 �/ 1 IO T r I I PG SITE PLAN ---SCALE : I" ■ 30 DESIGN DATA NUMBER OF BEDROOMS 3ExY�T -E 1 P¢op = G.P.D./BEDROOM 1 k G.P.D. TOTAL DAILY FLOW 440 G.P.D. GARBAGE DISPOSAL 00 LEACHING REQUIRED � G.P.D. LEACHING PROVIDED 4-TF5 G.P.D. SIDEWALL AREA-P0XI,'5S.F. x 2.5 - 300 G.P.D BOTTOM AREA = 55915 S.F. x 0 - J-iS G.P.D TOTAL PROVIDED- 295 S.F. 415 G.P.D 41 v5 > 4.40 G.P.D. NOTE: EXCAVATE TO EL. OR LOWER AS SOIL CONDITIONS REQUIRE TO REMOVE ALL TOPSOIL, SUBSOIL, CLAY OR OTHER UNSUITABLE MATERIAL BENEATH THE INLET INVERT OF THE LEACHING PIT FOR A DISTANCE OF 10' AROUND THE PIT AND BACKFILL WITH CLEAN SAND HAVING A PERC. RATE OF 2 MIN./INCH IN PLACE. PR,DS? GARALSE A�OITio,1 LEGEND u/IT14 r�ooM ABOVE /2 ��tTlo�lA '[,)9 %\A5 WA`( EXISTING SPOT ELEV.: 23.50 EXISTING CONTOUR : 4— PROPOSED SPOT ELEV. 24.75 n 0 PROPOSED CONTOUR: 261 0 TEST HOLE g NCM`.tNl D�l Mlco), fk, I2'M5 UVIL o" �fCi$ICRE� a` p s At ZONING DISTRICT FLOOD ZONE ELEVATION A-11 Io MAPS£C PCL LOT HSE 10 #2 0 i SOILS LOG & PERCOLATION TEST TEST HOLE I TEST HOLE 2 FI FV - FI FV - TOPSOIL ✓1 SUBSOIL i !PERCOLATION RATE: ITESTS BY: WITNESSED BY DATE WATER ENCOUNTERED AT MIN./INCH BOARD OF HEALTH: GENERAL NOTES I. ELEVATIONS BASED UPON DATUM. 2. ELEVATIONS AND LOCATIONS SHOWN ON THIS PLAN ARE NOT TO CHANGE WITHOUT WRITTEN APPROVAL OF TNF ENGINEER AND THE TOWN HEALTH AGENT. 3. ALL SYSTEM COMPONENTS ARE TO BE INSTALLED IN ACCORDANCE WITH S.E.C. TITLE V AND LOCAL HEALTH RULES AND REGULATIONS. 4, ALL PIPES ARE TO BE CAST IRON OR P.V.C. SCH. 40. 5. THE BOARD OF HEALTH AND/OR ENGINEER TO BE NOTIFIED WHEN SYSTEM IS COMPLETELY INSTALLED AND READY FOR INSPECTION. 6. NORTH ARROW IS NOT TO BE USED FOR SOLAR ORIENTATION. 7. WHEN COMPONENTS ARE SET SUCH THAT THE TOP OF STRUCTURE IS GREATER THAN 4' BELOW FINISH GRADE, HEAVY -TOP OR H-20 LOAD UNITS SHALL BE REQUIRED. To(;kf: ,c rA-PNY FrtoM r1tA.1 00. 81-1556-10 3`( R.J. r) HGNe*1 r I.1C., Iz.t,S,� R.S.. e3OJLDId67 LoGATI00 F2oM Puha-\ 1-10 e2- 056,. 10 r3�( 5A"e- I REV I BY I DATE I DESCRIPTION PLAN SHOWING PROP,"ADDITION LOT 10 GREEN TEAL WAY YARMOUTHPORT, MA. APPLICANT: MARIO MARSANO ADDRESS: 65 MORTON STREET MILTON, MA. ENGINEER: NORMAN GROSSMAN, R.P.E. 10 MARSH VIEW ROAD EAST FALMOUTH, MA. 508-34e-1920 SCALE DATE _ DWN. BY / CK -D BY AS NOTED NOV. 3, 1993 JTH / NG PLAN NO. H- 3Z5 w w ' PRECAST, C.I. OR P.V.C. TEES Q 1000 GALLON SEPTIC TANK l H-10 LOADING d TI e'-6• _1 r TO BE SET ON A LEVEL AND STABLE BASE I ACME ST -1000 OR APPROVED EQUAL ) SEPTIC SYSTEM PROFILE FIN. GRADE OVER FIN. GRADE OVER DIST. BOX LEACHING TRENCH 2" of 1/8--1/2., - I WASFIFD PEAST014E 4" Perforated PVC Pipe 2.. S >• �s.�•. 3/4" - 1-1/2" WASHED CRUSHED STONE DIST. 80X ! r---- -----�----► 15 EFFECTIVE LENGTH H-10 LOADING TO BE SET ON A - LEVEL d STABLE I 1a" EFFECTIVE BASE TOTAL NUMBER I DEPTH I ACME DB -3 OR OF APPROVED EQUAL) 5-0 ( Profile no to scale EFFECTIVE WIDTH 1 Ex I15T LEACHING TRENCH L1/F `FOVJO o1= `,(4J7-)M00TTH OVEp�Cct�OvJ>� t�,C�!r z ESE or- � C7ITG1-t � 4o' l=- �� S o'- 05'- 23 �- 3° E>u -sT- r2 ITc p (F io 5 tel'- 23 3g' E :9P� CP p 4--l' 40" F= LOT 10 2rD, 3e!>0j .5. IF \yJ } srAKE� I�vY s3c.0-E o�kE .— F AT LIMIT oP LD �\ 'PLAN REFERENCE: SARNST. CNTY. REG. PLAN SK � -Q N O Ce J p t q.7 33 < 11.15 ESGIST Ie..lCx _N t/ 3 v��nRoc�15 �/ 1 IO T r I I PG SITE PLAN ---SCALE : I" ■ 30 DESIGN DATA NUMBER OF BEDROOMS 3ExY�T -E 1 P¢op = G.P.D./BEDROOM 1 k G.P.D. TOTAL DAILY FLOW 440 G.P.D. GARBAGE DISPOSAL 00 LEACHING REQUIRED � G.P.D. LEACHING PROVIDED 4-TF5 G.P.D. SIDEWALL AREA-P0XI,'5S.F. x 2.5 - 300 G.P.D BOTTOM AREA = 55915 S.F. x 0 - J-iS G.P.D TOTAL PROVIDED- 295 S.F. 415 G.P.D 41 v5 > 4.40 G.P.D. NOTE: EXCAVATE TO EL. OR LOWER AS SOIL CONDITIONS REQUIRE TO REMOVE ALL TOPSOIL, SUBSOIL, CLAY OR OTHER UNSUITABLE MATERIAL BENEATH THE INLET INVERT OF THE LEACHING PIT FOR A DISTANCE OF 10' AROUND THE PIT AND BACKFILL WITH CLEAN SAND HAVING A PERC. RATE OF 2 MIN./INCH IN PLACE. PR,DS? GARALSE A�OITio,1 LEGEND u/IT14 r�ooM ABOVE /2 ��tTlo�lA '[,)9 %\A5 WA`( EXISTING SPOT ELEV.: 23.50 EXISTING CONTOUR : 4— PROPOSED SPOT ELEV. 24.75 n 0 PROPOSED CONTOUR: 261 0 TEST HOLE g NCM`.tNl D�l Mlco), fk, I2'M5 UVIL o" �fCi$ICRE� a` p s At ZONING DISTRICT FLOOD ZONE ELEVATION A-11 Io MAPS£C PCL LOT HSE 10 #2 0 i SOILS LOG & PERCOLATION TEST TEST HOLE I TEST HOLE 2 FI FV - FI FV - TOPSOIL ✓1 SUBSOIL i !PERCOLATION RATE: ITESTS BY: WITNESSED BY DATE WATER ENCOUNTERED AT MIN./INCH BOARD OF HEALTH: GENERAL NOTES I. ELEVATIONS BASED UPON DATUM. 2. ELEVATIONS AND LOCATIONS SHOWN ON THIS PLAN ARE NOT TO CHANGE WITHOUT WRITTEN APPROVAL OF TNF ENGINEER AND THE TOWN HEALTH AGENT. 3. ALL SYSTEM COMPONENTS ARE TO BE INSTALLED IN ACCORDANCE WITH S.E.C. TITLE V AND LOCAL HEALTH RULES AND REGULATIONS. 4, ALL PIPES ARE TO BE CAST IRON OR P.V.C. SCH. 40. 5. THE BOARD OF HEALTH AND/OR ENGINEER TO BE NOTIFIED WHEN SYSTEM IS COMPLETELY INSTALLED AND READY FOR INSPECTION. 6. NORTH ARROW IS NOT TO BE USED FOR SOLAR ORIENTATION. 7. WHEN COMPONENTS ARE SET SUCH THAT THE TOP OF STRUCTURE IS GREATER THAN 4' BELOW FINISH GRADE, HEAVY -TOP OR H-20 LOAD UNITS SHALL BE REQUIRED. To(;kf: ,c rA-PNY FrtoM r1tA.1 00. 81-1556-10 3`( R.J. r) HGNe*1 r I.1C., Iz.t,S,� R.S.. e3OJLDId67 LoGATI00 F2oM Puha-\ 1-10 e2- 056,. 10 r3�( 5A"e- I REV I BY I DATE I DESCRIPTION PLAN SHOWING PROP,"ADDITION LOT 10 GREEN TEAL WAY YARMOUTHPORT, MA. APPLICANT: MARIO MARSANO ADDRESS: 65 MORTON STREET MILTON, MA. ENGINEER: NORMAN GROSSMAN, R.P.E. 10 MARSH VIEW ROAD EAST FALMOUTH, MA. 508-34e-1920 SCALE DATE _ DWN. BY / CK -D BY AS NOTED NOV. 3, 1993 JTH / NG PLAN NO. H- 3Z5