HomeMy WebLinkAboutDecision 4213 - Site Plan Page 2WALL CX. REMOVAL DETAILS ADJACENT GRADE VARIES --MAX. WALL HEIGHT 10 SCALE: 1 ,,= 20' PROPOSED WALL 1' OFF PROPERTY LINE UNILOCK CONCORD OR ROMAN WALL PROPOSED TOP WALL=8.1 ONE BLOCK COURSE BELOW GRADE LOCK CONCORD OR ROMAN WALL PROPOSED TOP WALL=8.1 ADJACENT GRADE VARIES ---MAX. WALL HEIGHT=18" WALL SECTION SCALE: 1 "=2' 8" X 6" 14" BLOCKS COMPACTED GRANDULAR BASE 22" WIDE & 8" DEEP REV. 9/02/08 --NO CHANGES ON THIS SHEET REV. 7/15/08 --PROPOSED FOOTPRINT, LOT COVERAGE & OFFSETS REV. 6/18/08--2 SEPTIC SYSTEMS & NEW OWNER REV. 5/30/08 --WALL CROSS SECTION REV. 5/29/08--C-4 UNITS REV. 5/23/08--PRES8Y SYSTEM COPING WALL 1' OFF PROPERTY LINE REPLUMB SEWER OUT FRONT PROPOSED INVERT 30" BELOW GRADE. DOUBLE SLEEVE BOTH SEWER AND WATER WITHIN 10' OF EACH OTHER. ALARM & PUMP NOTES T. ALARM TO BE WIRED BY ELECTRICIANS ON SEPARATE CIRCUIT FROM PUMP. 2. ELECTRICAL WORK TO BE INSPECTED BY WIRING INSPECTOR. 3. ALARM TO BE LOCATED IN HOUSE- 5. OUSE5. USE 2 MEYER ME3H, 3/10 14P PUMPS. OR EQUIVALENT, 6, TO PROVIDE FOR EASY- AND SAFE MAINTENANCE OF PUMP: -PROVIDE UNION/DISCONNECT IN 2" PVC UNE AT TOP PUMP CHAMBER SO PUMP CAN BE REMOVED FROM TOP OF TANK. MONOLITHIC 1000 GALLON H-10 PUMP CHAMBER W/ WATERPROOFING 0.75 IMPERVIOUS BARRIER 40 MIL TITLE 5 SAND Alarm SYSTEM B¢ -UNIT 25 Invert 5.75 H-10 S=1 /8"/f Propo i 1500 Invert 5.55 Monoli tic I Proposed W/Waterl I I Bottom 1.05 Proposed �✓ I 6" Stone or caml 1 -1T-j DESIGN DATA 2 CULTEC C-4 UNITS Invert 5.30 24' X 12' X 3'DEEP SAND BEDS (Use Gas (See Detal) .Existing Invert 6.80 Use 12" Cover Proposed with 7.21 see detail flow Eq,aizer8 Top Units ®Filter Cloth 4" Inspection ID S=1/8"/ft „��� Port Sanitary Tee Invert 6.75 ,Proposed Proposed 1 5' 1 1 t>? 1 4 1 r 5 l 14 16 1-4, Q , ---- 3" 6:5 4Levet Bottom C-4 Units El: 2.5 0.15' Adjustment Pro- vided --Locus is within 300' of coast BEDROOMS: 2 GARBAGE GRINDER: No LEACH AREA REQUIRED CAPACITY: 220 GPD USE 2 C-4- UNITS WITH 4' OF STONE ALL AROUND SEPTIC TANK: 1500 GAL FOR A 24' X 12' X 3" DEEP LEACH AREA, MINUS BOTTOM LEACHING AREA: 287.3 SF A 1' X 17" TRIANGLE, AS SHOWN. RUN PERFOR- L(24' X 12')] -1'/2 X 1.42 ATED PIPE DOWN CENTER OF C-4 UNITS BETWEEN SIDE LEACHING AREA: 17.8 SF HUMPS. CAPE END. BRING STONE TO TOP OF C-4 [(71.3' PERIMETER) x 0.25] UNITS_ AND COVER WITH FILTER CLOTH. DESIGN CAPACITY: 225 GPD [(287.3 SF + 17.8 sf) X .74 GPD/SF] 2' MIN. REMOVAL WITH BARRIER PUMP CHAMBER STORAGE CAPACITY: 220 GAL. DO ALL AROUND AND UNDER REMOVAL DOWN 37"t DOSES PER DAY: 2 TO LOAMY SAND, AS SHOWN. BUOYANCY CALC'S-MONOLITHIC PUMP CHAMBER WEIGHT OF EMPTY CHAMBER AND 24" OF COVER CHAMBER= 4.15 TON (PER SHOREY) 24" COVER= 2' X 5.42' X 8.25` X 0.055 TON/CU. FT 24" COVER=4.92 TON TOTAL= 4.15 TON + 4.92 TON=9.07 TON WEIGHT OF WATER --HIGH GROUNDWATER DOWN (3.0 -0.75') X 5.42' X 8.25' X 0.0312- TON/CU. FT. WEIGHT WATER=3.14 TON TANK AND 24" COVER ARE HEAVIER BY 5.9 TON. 3/8" WEEP/VENT HOLES STONE UNDER 2" PVC Valves MAKE FACTORY WATER -TIGHT HEALTH AGENT APPROVAL BUOYANCY CAL'S MONOLITHIC 1500 GAL. ;H-10 WEIGHT OF EMPTY SEPTIC TANK AND 20" OF COVER TANK= 5.635 TON (PER SHOREY) 20" COVER=1.67' X 6.08' X 10.17' X 0.055 TON/CU. FT. 20" COVER=5.68 TON TOTAL= 5.635 TON + 5.68 TON = 11.31 TON WEIGHT OF WATER --HIGH GROUNDWATER DOWN (3.0 -1.05) X 6.08' X 10.17' X 0.0312 TON/CU. FT. WEIGHT WATER= 3.76 TON TANK AND 20" COVER ARE HEAVIER BY 7.5 TON. SITE PLAN FOR JAMES O. MORRISON LOT 106, 23 & 25 NEW HAMPSHIRE AVE, W. YARMOUTH, MA NOVEMBER 28, 2003 SCALE: 1"=20' RONALD J. CADILLAC, PLS, RS, P.C. PROFESSIONAL LAND SURVEYOR & REGISTERED SANITARIAN P.O. BOX 258 WEST YARMOUTH, MA 02673 DATE2()0$ BY R.J. CADILLAC (508)' 775-9700' PAGE 2 OF 2